Time-Course Reduction in Patient Exposure to Radiation From Coronary Interventional Procedures The Greater Paris Area Percutaneous Coronary Intervention Registry

被引:10
|
作者
Georges, Jean-Louis [1 ]
Karam, Nicole [4 ,5 ,8 ]
Tafflet, Muriel [4 ,8 ]
Livarek, Bernard [1 ]
Bataille, Sophie [2 ,9 ]
Loyeau, Aurelie [9 ]
Mapouata, Mireille [9 ]
Benamer, Hakim [10 ,11 ]
Caussin, Christophe [12 ]
Garot, Philippe [13 ]
Varenne, Olivier [4 ,6 ]
Barbou, Franck [14 ]
Teiger, Emmanuel [7 ]
Funck, Francois [15 ]
Karrillon, Gaetan [16 ]
Lambert, Yves [3 ]
Spaulding, Christian [4 ,5 ,8 ]
Jouven, Xavier [5 ,8 ]
机构
[1] Versailles Hospital Andre Mignot, Cardiol Dept, Le Chesnay, France
[2] Versailles Hospital Andre Mignot, Emergency Dept, Le Chesnay, France
[3] Versailles Hospital Andre Mignot, SAMU 78, Le Chesnay, France
[4] Paris Cardiovasc Res Ctr, INSERM, Unit 970, Paris, France
[5] European Georges Pompidou Univ Hosp, Cardiol Dept, Paris, France
[6] Univ Hosp Cochin, Cardiol Dept, Paris, France
[7] Univ Hosp Henri Mondor, AP HP, Cardiol Dept, Creteil, France
[8] Univ Paris 05, Paris, France
[9] ARSIF, Paris, France
[10] Foch Hosp, Cardiol Dept, Suresnes, France
[11] ICPS, Cardiol Dept, Massy, France
[12] Inst Mutualiste Montsouris, Cardiol Dept, Paris, France
[13] ICPS, Cardiol Dept, Quincy Sous Senart, France
[14] Hop Instruct Armees Percy, Cardiol Dept, Clamart, France
[15] Rene Dubos Hosp, Cardiol Dept, Pontoise, France
[16] Simone Veil Hosp, Cardiol Dept, Eaubonne, France
关键词
catheterization; coronary angiography; fluoroscopy; Kerma area product; percutaneous coronary intervention; radiation protection; CARDIOLOGY PROCEDURES; SWISS POPULATION; ANGIOGRAPHY; OUTCOMES; SAFETY; VALUES; LEVEL; HEART;
D O I
10.1161/CIRCINTERVENTIONS.117.005268
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The frequency of complex percutaneous coronary interventions (PCIs) has increased in the last few years, with a growing concern on the radiation dose received by the patients. Multicenter data from large unselected populations on patients' radiation doses during coronary angiography (CA) and PCI and temporal trends are lacking. This study sought to evaluate the temporal trends in patients' exposure to radiation from CA and PCI. Methods and Results-Data were taken from the CARDIO-ARSIF registry that prospectively collects data on all CAs and PCIs performed in the 36 catheterization laboratories in the Greater Paris Area, the most populated regions in France with about 12 million inhabitants. Kerma area product and Fluoroscopy time from 152 684 consecutive CAs and 103 177 PCIs performed between 2009 and 2013 were analyzed. A continuous trend for a decrease in median [interquartile range] Kerma area product was observed, from 33 [19-55] Gy cm(2) in 2009 to 27 [16-44] Gy cm(2) in 2013 for CA (P<0.0001), and from 73 [41-125] to 55 [31-91] Gy cm(2) for PCI (P<0.0001). Time-course differences in Kerma area product remained highly significant after adjustment on Fluoroscopy time, PCI procedure complexity, change of x-ray equipment, and other patient-and procedure-related covariates. Conclusions-In a large patient population, a steady temporal decrease in patient radiation exposure during CA and PCI was noted between 2009 and 2013. Kerma area product reduction was consistent in all types of procedure and was independent of patient-related factors and PCI procedure complexity.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Time-Course Reduction in Patient Exposure to Radiation From Coronary Interventional Procedures: The Greater Paris Area Percutaneous Coronary Intervention Registry (vol 10, e005268, 2017)
    Georges, J. L.
    Karam, N.
    Tafflet, M.
    Livarek, B.
    Bataille, S.
    Loyeau, A.
    Mapouata, M.
    Benamer, H.
    Caussin, C.
    Garot, P.
    Varenne, O.
    Barbou, F.
    Teiger, E.
    Funck, F.
    Karrillon, G.
    Lambert, Y.
    Spaulding, C.
    Jouven, X.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (09)
  • [2] Patient radiation exposure related to complexity of coronary interventional procedures
    Federman, J
    Cusma, JT
    Holmes, DR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 54A - 54A
  • [3] Real-time measurement of radiation exposure to patients during diagnostic coronary angiography and percutaneous interventional procedures
    Cusma, JT
    Bell, MR
    Wondrow, MA
    Taubel, JP
    Holmes, DR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (02) : 427 - 435
  • [4] Predictors of late coronary thrombotic events after percutaneous coronary intervention: insights from the PARIS registry
    Giustino, G.
    Sartori, S.
    Ariti, C.
    Hermiller, J. B.
    Cohen, D. J.
    Pocock, S.
    Waksmann, R.
    Kini, A.
    Colombo, A.
    Mehran, R.
    EUROPEAN HEART JOURNAL, 2015, 36 : 511 - 511
  • [5] Evolution of Australian Percutaneous Coronary Intervention (from the Melbourne Interventional Group [MIG] Registry)
    Yeoh, Julian
    Yudi, Matias B.
    Andrianopoulos, Nick
    Yan, Bryan P.
    Clark, David J.
    Duffy, Stephen J.
    Brennan, Angela
    New, Gishel
    Freeman, Melanie
    Eccleston, David
    Sebastian, Martin
    Reid, Christopher M.
    Wilson, William
    Ajani, Andrew E.
    AMERICAN JOURNAL OF CARDIOLOGY, 2017, 120 (01): : 47 - 54
  • [6] An evaluation of octogenarians undergoing percutaneous coronary intervention from the Melbourne interventional group registry
    Yan, Bryan P.
    Gurvitch, Ronen
    Duffy, Stephen J.
    Clark, David J.
    Sebastian, Martin
    New, Gishel
    Warren, Roderick
    Lefkovits, Jeffery
    Lew, Robert
    Brennan, Angela L.
    Reid, Chris
    Andrianopoulos, Nick
    Ajani, Andrew E.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (07) : 928 - 936
  • [7] Predictors of late bleeding after percutaneous coronary intervention: insights from the PARIS registry
    Giustino, G.
    Sartori, S.
    Ariti, C.
    Weisz, G.
    Stuckey, T.
    Pocock, S.
    Shawl, F.
    Gibson, C. M.
    Chieffo, A.
    Mehran, R.
    EUROPEAN HEART JOURNAL, 2015, 36 : 554 - 554
  • [8] Patient radiation exposure dose reduction using stent-enhanced image processing in percutaneous coronary intervention
    Mori, Kazuya
    Negishi, Toru
    Makabe, Kouhei
    Sekiguchi, Ryou
    Tsuchida, Takuji
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (02) : 433 - 440
  • [9] Marked Reduction Of Operator Radiation Exposure By Using A Patient Lead Cover During Coronary Angiography Or Percutaneous Intervention
    Ohlmann, Patrick
    Bouyer, Pauline
    Radulescu, Bogdan
    Mertz, Luc
    Morel, Olivier
    Zupan, Michel
    Bronner, Francois
    Bareiss, Pierre
    Constantinesco, Andre
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 38D - 39D
  • [10] Marked reduction of operator radiation exposure by using a patient lead cover during coronary angiography or percutaneous intervention
    Radulescu, B.
    Bouyer, P.
    Mertz, L.
    Morel, O.
    Le Dret, S.
    Zupan, M.
    Bronner, F.
    Constantinesco, A.
    Ohlmann, P.