Estimated collective effective dose to the population from nuclear medicine diagnostic procedures in Croatia: A comparison of 2010 and 2015

被引:8
|
作者
Kralik, Ivana [1 ]
Stefanic, Mario [2 ,3 ]
Brkic, Hrvoje [2 ]
Saric, Gordan [2 ,3 ]
Tezak, Stanko [4 ]
Ivankovic, Svjetlana Grbac [5 ,6 ]
Griotto, Neva [5 ,6 ]
Stimac, Damir [2 ,3 ]
Rubin, Otmar [2 ,3 ]
Salha, Tamer [2 ,3 ]
Ivanisevic, Zrinka [2 ]
Jurkovic, Slaven [5 ,6 ]
Faj, Dario [2 ]
机构
[1] State Off Radiol & Nucl Safety, Zagreb, Croatia
[2] Josip Juraj Strossmayer Univ Osijek, Fac Med, Osijek, Croatia
[3] Univ Hosp Ctr Osijek, Osijek, Croatia
[4] Univ Hosp Ctr Zagreb, Zahreb, Croatia
[5] Univ Hosp Ctr Rijeka, Rijeka, Croatia
[6] Univ Rijeka, Fac Med, Rijeka, Croatia
来源
PLOS ONE | 2017年 / 12卷 / 06期
关键词
URINARY-TRACT-INFECTION; FEBRILE INFANTS; UTI;
D O I
10.1371/journal.pone.0180057
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective This study presents national surveys of patient exposure from nuclear medicine (NM) diagnostic procedures in 2010 and 2015 in the Republic of Croatia. Methods The survey was performed according to the European Commission Dose DataMed (DDM) project methodology. 28 most frequent NM diagnostic procedures were identified. Data about frequencies of procedures and average administered activities of radioisotopes used in those procedures were collected. Average administered activities were converted to effective doses according to the dose conversion coefficients. Then the collective effective dose to the population and an effective dose per capita were calculated based on the number of the most frequent NM diagnostic procedures and the average effective dose per procedure. Results In 2010, 41200 NM diagnostic procedures led to 146.7 manSv collective effective dose to the population and in 2015, 42000 NM diagnostic procedures led to 146.8 manSv collective effective dose to the population. The frequencies of NM diagnostic procedures were 9.7 and 9.8 annually per 1000 population with 34.1 pSv and 34.2 pSv effective dose per capita for 2010 and 2015, respectively. The main contributors to the annual collective dose from NM in Croatia are examinations of the bone, heart, thyroid and PET/CT tumour diagnostic. Average administered activities have not changed considerably from 2010 to 2015. Nevertheless, within the frequency of some of the procedures, significant changes were found in fiveyear period. Conclusions Frequencies, average administered activities and collective effective dose to the population from NM diagnostic procedures in Croatia are comparable to the values reported by other European surveys. Changes were found between 2010 and 2015 and we intend to perform this study periodically to identify possible trends, but also to raise awareness about the potential dose optimization.
引用
收藏
页数:13
相关论文
共 50 条
  • [2] Estimated collective effective dose to the population from nuclear medicine examinations in Slovenia
    Skrk, Damijan
    Zontar, Dejan
    [J]. RADIOLOGY AND ONCOLOGY, 2013, 47 (03) : 304 - 310
  • [3] Collective effective dose from radiopharmaceuticals for Nuclear Medicine diagnostic procedures in patients in 2009
    Lopez Lorenzo, B.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S341 - S341
  • [4] ESTIMATED COLLECTIVE EFFECTIVE DOSE TO THE POPULATION FROM X-RAY AND NUCLEAR MEDICINE EXAMINATIONS IN FINLAND
    Bly, R.
    Jarvinen, H.
    Korpela, M. H.
    Tenkanen-Rautakoski, P.
    Makinen, A.
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 147 (1-2) : 233 - 236
  • [5] Effective dose from diagnostic nuclear medicine procedures in northern Greece
    Hatziioannou, KA
    Hatzigiannaki, A
    MolyvdaAthanasopoulou, E
    Sioundas, A
    Kostaki, P
    Psarrakos, K
    [J]. IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C494 - C496
  • [6] Population effective collective dose from nuclear medicine examination in Cuba
    Brigido Flores, O.
    Barreras Caballero, A.
    Lasserra Sanchez, O.
    Montalvan Estrada, A.
    Hernandez Garcia, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2006, 121 (04) : 438 - 444
  • [7] COLLECTIVE EFFECTIVE DOSE IN EUROPE FROM X-RAY AND NUCLEAR MEDICINE PROCEDURES
    Bly, R.
    Jahnen, A.
    Jarvinen, H.
    Olerud, H.
    Vassileva, J.
    Vogiatzi, S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 129 - 132
  • [8] Exposures from nuclear medicine diagnostic procedures: the dose impact on the Aosta Valley population
    Aimonetto, S.
    Arrichiello, C.
    Cornetto, A. Peruzzo
    Catuzzo, P.
    Zeverino, M.
    Poti, C.
    Meloni, T.
    Pasquino, M.
    Tofani, S.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 157 (03) : 339 - 347
  • [9] Estimated collective effective dose to the population from radiological examinations in Slovenia
    Zontar, Dejan
    Zdesar, Urban
    Kuhelj, Dimitrij
    Pekarovic, Dean
    Skrk, Damijan
    [J]. RADIOLOGY AND ONCOLOGY, 2015, 49 (01) : 99 - 106
  • [10] Estimated dose from diagnostic nuclear medicine patients to people outside the Nuclear Medicine department
    Bartlett, Marissa L.
    [J]. RADIATION PROTECTION DOSIMETRY, 2013, 157 (01) : 44 - 52