Novel aspects of quantitation of immunogenic wheat gluten peptides by liquid chromatography-mass spectrometry/mass spectrometry

被引:68
|
作者
Sealey-Voyksner, Jennifer A. [1 ,2 ]
Khosla, Chaitan [3 ,4 ]
Voyksner, Robert D. [1 ]
Jorgenson, James W. [2 ]
机构
[1] LCMS Ltd, Durham, NC 27707 USA
[2] Univ N Carolina, Dept Chem, Chapel Hill, NC 27599 USA
[3] Stanford Univ, Dept Chem, Stanford, CA 94305 USA
[4] Stanford Univ, Dept Chem Engn & Biochem, Stanford, CA 94305 USA
关键词
Celiac sprue; Liquid chromatography-mass spectrometry; Gluten; Quantitation; CELIAC-DISEASE; STORAGE PROTEINS; QUANTIFICATION; DIGESTION; GLIADINS; ASSAYS; EP-B2;
D O I
10.1016/j.chroma.2010.01.067
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel, specific and sensitive non-immunological liquid chromatography-mass spectrometry (LC-MS) based assay has been developed to detect and quantify trace levels of wheat gluten in food and consumer products. Detection and quantification of dietary gluten is important, because gluten is a principle trigger of a variety of immune diseases including food allergies and intolerances. One such disease, celiac sprue, can cause intestinal inflammation and enteropathy in patients who are exposed to dietary gluten. At present, immunochemistry is the leading analytical method for gluten detection in food. Consequently, enzyme-linked immunosorbent assays (ELISAs), such as the sandwich or competitive type assays, are the only commercially available methods to ensure that food and consumer products are accurately labeled as gluten-free. The availability of a comprehensive, fast and economic alternative to the immunological ELISA may also facilitate research towards the development of new drugs, therapies and food processing technologies to aid patients with gluten intolerances and for gluten-free labeling and certification purposes. LC-MS is an effective and efficient analytical technique for the study of cereal grain proteins and to quantify trace levels of targeted dietary gluten peptides in complex matrices. Initial efforts in this area afforded the unambiguous identification and structural characterization of six unique physiologically relevant wheat gluten peptides. This paper describes the development and optimization of an LC-MS/MS method that attempts to provide the best possible accuracy and sensitivity for the quantitative detection of trace levels of these six peptides in various food and consumer products. The overall performance of this method was evaluated using native cereal grains. Experimental results demonstrated that this method is capable of detecting and quantifying select target peptides in food over a range from 10 pg/mg to 100 ng/mg (corresponding to approximately 0.01-100 ppm). Limits of detection CLOD) and quantification (LOQ) for the six target peptides were determined to range from 1 to 30 pg/mg and 10-100 pg/mg respectively. Reproducibility of the assay was demonstrated by evaluation of calibration data as well as data collected from the analysis of quality control standards over a period of four consecutive days. The average coefficient of determination (R-2) for each peptide was consistently found to be >0.995 with residuals ranging from approximately 80% to 110%. Spike recovery data for each peptide in various matrices was evaluated at a concentration level near the approximate LOQ for each, as well as at higher concentration levels (30 and 60 ng/mg). The average range of accuracy of detection for all peptides at the lower concentration level was determined to be 90% (+/- 11), while accuracy at the 30 and 60 ng/mg levels was 98% (+/- 5%) and 98% (+/- 3%), respectively. The usefulness and capabilities of this method are presented in a practical application to prospectively screen a variety of common commercially available (native and processed) gluten-containing and gluten-free foods and products. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:4167 / 4183
页数:17
相关论文
共 50 条
  • [1] Quantitation of Specific Barley, Rye, and Oat Marker Peptides by Targeted Liquid Chromatography-Mass Spectrometry To Determine Gluten Concentrations
    Schalk, Kathrin
    Koehler, Peter
    Scherf, Katharina Anne
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2018, 66 (13) : 3581 - 3592
  • [3] LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY
    VESTAL, ML
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1981, 181 (MAR): : 79 - ANYL
  • [4] A compact liquid chromatography-mass spectrometry instrument for the quantitation of immunosuppressants
    Gu, Hao
    Dai, Guoxin
    Liu, Siyu
    Zhai, Yanbing
    Xu, Qian
    Wu, Hongqiang
    Xu, Wei
    CHINESE CHEMICAL LETTERS, 2023, 34 (04)
  • [5] Quantitation of hepcidin in human urine by liquid chromatography-mass spectrometry
    Bansal, Sukhvinder S.
    Halket, John M.
    Bomford, Adrian
    Simpson, Robert J.
    Vasavda, Nisha
    Thein, Swee Lay
    Hider, Robert C.
    ANALYTICAL BIOCHEMISTRY, 2009, 384 (02) : 245 - 253
  • [6] A compact liquid chromatography-mass spectrometry instrument for the quantitation of immunosuppressants
    Hao Gu
    Guoxin Dai
    Siyu Liu
    Yanbing Zhai
    Qian Xu
    Hongqiang Wu
    Wei Xu
    ChineseChemicalLetters, 2023, 34 (04) : 501 - 505
  • [7] Detection of gluten peptides in human duodenal fluids with immuno-liquid chromatography-mass spectrometry
    Dayon, Loic
    Galindo, Antonio Nunez
    Chevalier, Julien
    Aquarius, Michel
    Otten, Britt
    Troost, Freddy J.
    Duncan, Peter
    Affolter, Michael
    ANALYTICAL METHODS, 2024, 16 (40) : 6819 - 6828
  • [8] Widespread Contamination of Probiotics With Gluten, Detected by Liquid Chromatography-Mass Spectrometry
    Nazareth, Samantha
    Lebwohl, Benjamin
    Voyksner, Jennifer Sealey
    Green, Peter H.
    GASTROENTEROLOGY, 2015, 148 (04) : S28 - S28
  • [9] Quantitation and characterization of phospholipids in pharmaceutical formulations by liquid chromatography-mass spectrometry
    Carrier, A
    Parent, J
    Dupuis, S
    JOURNAL OF CHROMATOGRAPHY A, 2000, 876 (1-2) : 97 - 109
  • [10] Rapid quantitation of cyclophosphamide metabolites in plasma by liquid chromatography-mass spectrometry
    Kalhorn, TF
    Howald, WN
    Cole, S
    Phillips, B
    Wang, J
    Slattery, JT
    McCune, JS
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 835 (1-2): : 105 - 113