Precombustion CO2 Capture in Polymeric Hollow Fiber Membrane Contactors Using Ionic Liquids: Porous Membrane versus Nonporous Composite Membrane

被引:59
|
作者
Dai, Zhongde [1 ]
Ansaloni, Luca [1 ]
Deng, Liyuan [1 ]
机构
[1] Norwegian Univ Sci & Technol NTNU, Dept Chem Engn, N-7491 Trondheim, Norway
关键词
OF-THE-ART; CARBON-DIOXIDE; NONDISPERSIVE ABSORPTION; POSTCOMBUSTION CAPTURE; FLUE-GAS; REMOVAL; SEPARATION; PERFORMANCE; PROGRESS; MIXTURES;
D O I
10.1021/acs.iecr.6b01247
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the present work, membrane contactors using both porous and nonporous polymeric hollow fiber membranes with ionic liquids as absorbent were developed for precombustion CO2 capture at elevated temperature and pressures. 1-Butyl-3-methylimidazolium tricyanomethanide [Bmim] [TCM] was selected as the ILs absorbent. The compatibility and stability of six different polymeric membranes were evaluated, while the porous PTFE membrane and nonporous Teflon-PP composite membrane were considered to be the most suitable membranes for this application. Both membrane configurations were tested and showed comparable separation performances: CO2 flux values of 4.86 x 10(-4) and 4.75 x 10(-4) mol m(-2) s(-1) were obtained for the porous PTFE and nonporous Teflon-PP membrane contactor at 20 bar with a gas flow rate of 200 mL min(-1), respectively. The Teflon-PP composite membrane exhibited better stability as compared to the porous PTFE membrane in a 14 day test.
引用
收藏
页码:5983 / 5992
页数:10
相关论文
共 50 条
  • [1] Influence of membrane wetting on CO2 capture in microporous hollow fiber membrane contactors
    Wang, R
    Zhang, HY
    Feron, PHM
    Liang, DT
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2005, 46 (1-2) : 33 - 40
  • [2] Experimental study on the effects of an ionic liquid for CO2 capture using hollow fiber membrane contactors
    Rostami, Sadegh
    Keshavarz, Peyman
    Raeissi, Sona
    [J]. INTERNATIONAL JOURNAL OF GREENHOUSE GAS CONTROL, 2018, 69 : 1 - 7
  • [3] Part 7: A review of CO2 capture using hollow fiber membrane contactors
    [J]. Demontigny, D. (david.demontigny@uregina.ca), 1600, Future Science Ltd (04):
  • [4] Ammonia based CO2 capture process using hollow fiber membrane contactors
    Makhloufi, Camel
    Lasseuguette, Elsa
    Remigy, Jean Christophe
    Belaissaoui, Bouchra
    Roizard, Denis
    Favre, Eric
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2014, 455 : 236 - 246
  • [5] Part 7: A review of CO2 capture using hollow fiber membrane contactors
    Cui, Zheng
    deMontigny, David
    [J]. CARBON MANAGEMENT, 2013, 4 (01) : 69 - 89
  • [6] CO2 absorption by using PVDF hollow fiber membrane contactors with various membrane structures
    Rajabzadeh, Saeid
    Yoshimoto, Shinya
    Teramoto, Masaaki
    Al-Marzouqi, M.
    Matsuyama, Hideto
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2009, 69 (02) : 210 - 220
  • [7] Wetting mechanism of a PVDF hollow fiber membrane in immersed membrane contactors for CO2 capture in the presence of monoethanolamine
    Zhang, Zhaohui
    Wu, Xiaona
    Wang, Liang
    Zhao, Bin
    Li, Junjing
    Zhang, Hongwei
    [J]. RSC ADVANCES, 2017, 7 (22) : 13451 - 13457
  • [8] CO2 capture with membrane contactors
    Falk-Pedersen, O
    Gronvold, MS
    Nokleby, P
    Bjerve, F
    Svendsen, HF
    [J]. INTERNATIONAL JOURNAL OF GREEN ENERGY, 2005, 2 (02) : 157 - 165
  • [9] Analysis of CO2 removal by hollow fiber membrane contactors
    Lee, YT
    Noble, RD
    Yeom, BY
    Park, YI
    Lee, KH
    [J]. JOURNAL OF MEMBRANE SCIENCE, 2001, 194 (01) : 57 - 67
  • [10] Hollow Fiber Membrane Contactors in CO2 Desorption: A Review
    Manuel Vadillo, Jose
    Gomez-Coma, Lucia
    Garea, Aurora
    Irabien, Angel
    [J]. ENERGY & FUELS, 2021, 35 (01) : 111 - 136