An Improved Wearable Resonant Wireless Power Transfer System for Biomedical Capsule Endoscope

被引:144
|
作者
Basar, Md. Rubel [1 ,2 ]
Ahmad, Mohd Yazed [1 ]
Cho, Jongman [3 ]
Ibrahim, Fatimah [1 ]
机构
[1] Univ Malaya, Dept Biomed Engn, Fac Engn, Kuala Lumpur 50603, Malaysia
[2] Bangladesh Army Univ Engn & Technol, Dept Informat & Commun Engn, Qadirabad 6431, Natore, Bangladesh
[3] Inje Univ, Dept Biomed Engn, Gimhae 50834, South Korea
关键词
Inductive power transfer; multicoil inductive link; received power stability (RPS); wireless capsule endoscopy; wireless power transfer; TRANSMISSION-SYSTEM; EFFICIENCY; COIL; IMPLANTS; DESIGN; ROBOT;
D O I
10.1109/TIE.2018.2801781
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Magnetic resonant-based wireless power transfer system (WPTS) is an efficient way to energize critical biomedical devices, such as wireless capsule endoscopes, where a direct wire connection is not practical. However, low power transfer efficiency (PTE) and poor received power stability (RPS) are usually the main bottlenecks of WPTS in this application. Thus, this paper proposes an efficient WPTS that tremendously improves the PTE and enriches the RPS. In order to improve the PTE, an optimum three-coil inductive link is adopted with a compact wearable power transmitting coil-I (PTC-I) and a 2-3D power receiving coil. As a result, the stability is improved with the new configuration of the power transmission coil-III (PTC-III) and power combining technique at the receiving side. To confirm the validity of the proposed design, proof-of-concept prototypes were implemented for an experimental test. Results obtained from the experimental test assured that the proposed PTC-I-based system achieved a PTE of more than 8% while transferring 758 mW of power with 68.7% RPS. The best overall RPS attained by the proposed PTC-III based system is 79.2%. This system achieved a PTE of 5.4% transferring at least 570 mW of power. In comparison, the performance of the proposed designs greatly outweighs the previous designs.
引用
收藏
页码:7772 / 7781
页数:10
相关论文
共 50 条
  • [1] An improved resonant wireless power transfer system with optimum coil configuration for capsule endoscopy
    Basar, Md. Rubel
    Ahmad, Mohd Yazed
    Cho, Jongman
    Ibrahim, Fatimah
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2016, 249 : 207 - 216
  • [2] High-Efficiency Wireless Power Transfer System for Capsule Endoscope
    Miah, Md Suzan
    Jayathurathnage, Prasad
    Icheln, Clemens
    Haneda, Katsuyuki
    Tretyakov, Sergei
    [J]. 2019 13TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION AND COMMUNICATION TECHNOLOGY (ISMICT), 2019, : 32 - 36
  • [3] Wearable Permanent Magnet Tracking System for Wireless Capsule Endoscope
    Fu, Yuming
    Guo, Yong-Xin
    [J]. IEEE SENSORS JOURNAL, 2022, 22 (08) : 8113 - 8122
  • [4] Investigation of Wireless Power Transfer System with Different Coil Structures used in Wireless Capsule Endoscope
    Sravya, Duvvuru
    Bobba, Phaneendra Babu
    Rani, M. Naga Sandhya
    [J]. 2021 INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND FUTURE ELECTRIC TRANSPORTATION (SEFET), 2021,
  • [5] Design of a Biomedical Antenna System for Wireless Communication of Ingestible Capsule Endoscope
    Gao, Rushi
    Sun, Hucheng
    Ren, Rui
    Zhang, Haipeng
    [J]. IEEE Antennas and Wireless Propagation Letters, 2024, 23 (12): : 4243 - 4247
  • [6] Study of a wireless power transmission system for an active capsule endoscope
    Xin, Wenhui
    Yan, Guozheng
    Wang, Wenxin
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2010, 6 (01): : 113 - 122
  • [7] Resonant Inductive Power Transfer System for Freely Moving Capsule Endoscope with Highly Uniform Magnetic Field
    Basar, Rubel
    Ahmad, Mohd Yazed
    Ibrahim, Fatimah
    Cho, Jongman
    [J]. 2016 IEEE INDUSTRIAL ELECTRONICS AND APPLICATIONS CONFERENCE (IEACON), 2016, : 393 - 397
  • [8] Low Power Transmitter for Wireless Capsule Endoscope
    Lioe, D. X.
    Shafie, S.
    Ramiah, H.
    Sulaiman, N.
    Halin, I. A.
    [J]. 2013 INTERNATIONAL CONFERENCE ON SCIENCE & ENGINEERING IN MATHEMATICS, CHEMISTRY AND PHYSICS (SCIETECH 2013), 2013, 423
  • [9] 3-Coil Orientation Insensitive Wireless Power Transfer for Capsule Endoscope
    Ghotbi, Iman
    Najjarzadegan, M.
    Ashtiani, S. J.
    Shoaei, O.
    Shahabadi, M.
    [J]. 2015 23RD IRANIAN CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 1249 - 1254
  • [10] A 3-coil Wireless Power Transfer System with Fine Tuned Power Amplifier for Biomedical Capsule
    Basari, Md. Rubel
    Ahmad, Mohd Yazed
    Cho, Jongman
    Ibrahim, Fatimah
    [J]. 2017 IEEE ASIA PACIFIC MICROWAVE CONFERENCE (APMC), 2017, : 142 - 145