Space Charge Measurement Equipment for Full-Scale HVDC Cables Using Electrically Insulating Polymeric Acoustic Coupler

被引:22
|
作者
Zahra, Shafira [1 ]
Morita, Shosuke [1 ]
Utagawa, Masaki [1 ]
Kawashima, Tomohiro [1 ]
Murakami, Yoshinobu [1 ]
Hozumi, Naohiro [1 ]
Morshuis, Peter [2 ]
Cho, Young-, II [3 ]
Kim, Yoon-Hyoung [3 ]
机构
[1] Toyohashi Univ Technol, Dept Elect & Elect Informat Engn, Toyohashi, Aichi 4418580, Japan
[2] Solid Dielect Solut, NL-2311 SG Leiden, Netherlands
[3] LS Cable & Syst Ltd, Gangwon 25812, South Korea
关键词
Acoustics; Power cables; Voltage measurement; Couplers; Acoustic measurements; Insulation; Polymers; High-voltage dc (HVDC) transmission; polymer insulated cable; pulsed electro-acoustic (PEA) measurement; space charge; PULSED ELECTROACOUSTIC METHOD; XLPE CABLE; ACCUMULATION;
D O I
10.1109/TDEI.2022.3169106
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new, very sensitive device for space charge measurements on full-size cable is proposed. The measurement employs the basis of the pulsed electro-acoustic (PEA) method, in which an acoustic signal is produced due to the interaction between the pulsed electric field and the space charge. A polymeric material was used as an acoustic coupler that also isolates the cable and the measurement device electrically. It was found that the new type of device with polymeric coupler has a four times higher sensitivity than the conventional PEA device. The isolation from the cable body was proven to be advantageous for easily connecting the probing pulse voltage to the measurement section of the cable through its insulation screen (outer screen electrode) while applying a dc high voltage to the conductor. Feasibility of the new PEA device was examined using a cable with 20 mm-thick insulation. It was shown experimentally that PEA measurements performed at a voltage as low as 5 kV provided clear charge patterns. As a result of this, the accuracy of the electric field calculation was estimated to be 0.25 kV/mm or better, which leads to 2% of accuracy at 250 kV operating voltage.
引用
收藏
页码:1053 / 1061
页数:9
相关论文
共 4 条
  • [1] Small-size Space Charge Measurement Device for Power Cables by Using Electrically Insulated Acoustic Coupler
    Zahra, Shafira
    Kawashima, Tomohiro
    Murakami, Yoshinobu
    Hozumi, Naohiro
    PROCEEDINGS OF THE 2020 3RD IEEE INTERNATIONAL CONFERENCE ON DIELECTRICS (ICD 2020), 2020, : 359 - 362
  • [2] PEA Space Charge Measurement Technology for Full-scale Cables Based on Pulse Injection from Outer Semi-conductive Layer
    Wang X.
    Chen C.
    Xiong J.
    Wu K.
    Fu M.
    Hou S.
    Gaodianya Jishu/High Voltage Engineering, 2017, 43 (05): : 1677 - 1683
  • [3] Development of the Space Charge Measurement Techniques Based on Pulsed Electric-acoustic Method for HVDC Power Cables
    Xu, Xiaoxiao
    Lei, Zhipeng
    Song, Jiancheng
    Lin, Lingyan
    Zeng, Junxiang
    Li, Yanwen
    Wang, Shaofei
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [4] The Application of Signal Processing Using Dual Domain Deconvolution for New Space Charge Measurement Method in HVDC Full-Size Cables
    Prastika, Edo Bagus
    Zahra, Shafira
    Li, Xiaoxin
    Murakami, Yoshinobu
    Kawashima, Tomohiro
    Hozumi, Naohiro
    Kim, Yoonhyoung