Application of gallium film electrode for elimination of copper interference in anodic stripping voltammetry of zinc

被引:39
|
作者
Tyszczuk, Katarzyna [1 ]
Korolczuk, Mieczyslaw [1 ]
Grabarczyk, Malgorzata [1 ]
机构
[1] Marie Curie Sklodowska Univ, Fac Chem, PL-20031 Lublin, Poland
关键词
gallium film electrode; zinc; determination; stripping voltammetry;
D O I
10.1016/j.talanta.2006.09.021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For elimination of copper interference in anodic stripping determinations of zinc at mercury and bismuth film electrodes gallium ions are usually added to the supporting electrolyte. In the presented studies novel ex situ formed gallium film electrode was applied for this purpose. The proposed electrode is less toxic than mercury one while the detection limit for zinc was lower than for bismuth film electrode following the same deposition time. The calibration graph for deposition time of 60 s was linear from 5 x 10(-8) to 2 x 10(-6) mol L-1. The determinations of zinc were carried out from undeaerated solutions. The proposed procedure was applied to zinc determination in certified reference material and tap water sample. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:2098 / 2101
页数:4
相关论文
共 50 条
  • [1] ELIMINATION OF THE COPPER-ZINC INTERFERENCE IN ANODIC-STRIPPING VOLTAMMETRY BY ADDITION OF A COMPLEXING AGENT
    MARQUES, ALB
    CHIERICE, GO
    TALANTA, 1991, 38 (07) : 735 - 739
  • [2] Enhanced resolution of copper and bismuth by addition of gallium in anodic stripping voltammetry with the bismuth film electrode
    Prior, Chad
    Lenehan, Claire E.
    Walker, G. Stewart
    ELECTROANALYSIS, 2006, 18 (24) : 2486 - 2489
  • [4] ELIMINATION OF COPPER-ZINC INTERMETALLIC INTERFERENCES IN ANODIC-STRIPPING VOLTAMMETRY
    COPELAND, TR
    OSTERYOU.RA
    SKOGERBO.RK
    ANALYTICAL CHEMISTRY, 1974, 46 (14) : 2093 - 2097
  • [5] Investigation of Copper(II) Interference on the Anodic Stripping Voltammetry of Lead(II) and Cadmium(II) at Bismuth Film Electrode
    Yang, Die
    Wang, Liang
    Chen, Zuliang
    Megharaj, Mallavarapu
    Naidu, Ravi
    ELECTROANALYSIS, 2013, 25 (12) : 2637 - 2644
  • [6] Heated mercury film electrode for anodic stripping voltammetry
    Jasinski, M
    Kirbs, A
    Schmehl, M
    Gründler, P
    ELECTROCHEMISTRY COMMUNICATIONS, 1999, 1 (01) : 26 - 28
  • [7] ANODIC-STRIPPING VOLTAMMETRY OF LEAD USING A COPPER-MERCURY FILM ELECTRODE
    GUNASINGHAM, H
    DALANGIN, RR
    ANALYTICA CHIMICA ACTA, 1991, 246 (02) : 309 - 313
  • [8] A PYROLYTIC CARBON-FILM ELECTRODE FOR VOLTAMMETRY .3. APPLICATION TO ANODIC-STRIPPING VOLTAMMETRY
    GUSTAVSSON, I
    LUNDSTROM, K
    TALANTA, 1983, 30 (12) : 959 - 962
  • [9] Coulometric Anodic Stripping Voltammetry of Lead at Copper Column Electrode
    Kasuno, Megumi
    Osuga, Hitomi
    Shina, Katsuya
    Yamazaki, Takuya
    ELECTROANALYSIS, 2021, 33 (06) : 1502 - 1509
  • [10] OSCILLOPOLAROGRAPHIC ANODIC-STRIPPING VOLTAMMETRY AT THE MERCURY FILM ELECTRODE
    STOJEK, Z
    KUBLIK, Z
    CHEMIA ANALITYCZNA, 1985, 30 (03): : 363 - 368