Pulmonary venous flow velocity measurements for the quantitative assessment of mitral regurgitation

被引:0
|
作者
Seiler, C [1 ]
Aeschbacher, BC [1 ]
Meier, B [1 ]
机构
[1] UNIV HOSP BERN,CH-3010 BERN,SWITZERLAND
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:7114 / 7114
页数:1
相关论文
共 50 条
  • [1] The value of assessing pulmonary venous flow velocity for predicting severity of mitral regurgitation: A quantitative assessment integrating left ventricular function
    Pu, M
    Griffin, BP
    Vandervoort, PM
    Stewart, WJ
    Fan, XX
    Cosgrove, DM
    Thomas, JD
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (09) : 736 - 743
  • [2] Quantitation of mitral regurgitation using the systolic/diastolic pulmonary venous flow velocity ratio
    Seiler, C
    Aeschbacher, BC
    Meier, B
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) : 1383 - 1390
  • [3] Prominent pulmonary venous flow mimicking mitral regurgitation
    Srialluri, Swetha
    Arisha, Mohammed J.
    Abdelhaleem, Ahmed
    Farhoud, Adel A.
    Mahmoud, Mohamed S.
    Salama, Ahmed Y.
    Ibeche, Bashar
    Battisha, Ayman
    Nanda, Navin C.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (12): : 1917 - 1918
  • [4] FACTORS INFLUENCING PULMONARY VENOUS FLOW VELOCITY PATTERNS IN MITRAL REGURGITATION - AN IN-VITRO STUDY
    PASSAFINI, A
    SHIOTA, T
    DEPP, M
    PAIK, J
    GE, S
    SHANDAS, R
    SAHN, DJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (05) : 1333 - 1339
  • [5] AN IN-VITRO STUDY OF FACTORS INFLUENCING PULMONARY VENOUS FLOW VELOCITY PATTERNS IN MITRAL REGURGITATION
    PASSAFINI, A
    PAIK, J
    GE, SP
    QIAN, YQ
    GONG, Z
    CIRCULATION, 1994, 90 (04) : 593 - 593
  • [6] LIMITATIONS OF PULMONARY VENOUS FLOW CRITERIA IN THE ASSESSMENT OF MITRAL REGURGITATION SEVERITY BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    JAIN, S
    HELMCKE, F
    FAN, PH
    BHIMANI, S
    NANDA, NC
    CIRCULATION, 1990, 82 (04) : 551 - 551
  • [7] QUANTITATIVE ASSESSMENT OF ACCURACY AND PITFALLS OF DOPPLER PULMONARY VENOUS FLOW IN ASSESSMENT OF MITRAL REGURGITANT SEVERITY
    PU, M
    VANDERVOORT, PM
    GRIFFIN, BP
    FAN, XX
    COSGROVE, DM
    THOMAS, JD
    CIRCULATION, 1995, 92 (08) : 3459 - 3459
  • [10] Determinants of pulmonary venous flow reversal in mitral regurgitation and its usefulness in determining the severity of regurgitation
    Enriquez-Sarano, M
    Dujardin, KS
    Tribouilloy, CM
    Seward, JB
    Yoganathan, AP
    Bailey, KR
    Tajik, AJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 83 (04): : 535 - 541