Biosafety, stability, and osteogenic activity of novel implants made of Zr70Ni16Cu6Al8 bulk metallic glass for biomedical application

被引:25
|
作者
Ida, Iiiroto [1 ]
Seiryu, Masahiro [1 ]
Takeshita, Nobuo [1 ]
Iwasaki, Masanari [1 ]
Yokoyama, Yoshihiko [2 ]
Tsutsumi, Yusuke [3 ,4 ]
Ikeda, Etsuko [1 ]
Sasaki, Satoshi [1 ]
Miyashita, Shunro [1 ]
Sasaki, Shutaro [1 ]
Fukunaga, Tomohiro [1 ]
Deguchi, Toru [1 ,5 ]
Takano-Yamamoto, Teruko [1 ]
机构
[1] Tohoku Univ, Grad Sch Dent, Div Orthodont & Dentofacial Orthoped, Sendai, Miyagi, Japan
[2] Tohoku Univ, IMR, Cooperat Res & Dev Ctr Adv Mat, Sendai, Miyagi, Japan
[3] Tokyo Med & Dent Univ, Inst Biomat & Bioengn, Chiyoda Ku, Tokyo, Japan
[4] Univ Tokyo, Dept Mat Engn, Bunkyo Ku, Tokyo, Japan
[5] Ohio State Univ, Coll Dent, Div Orthodont, Columbus, OH 43210 USA
基金
日本学术振兴会;
关键词
Bulk metallic glass; Implants; Biosafety; Osteogenic activity; Biocompatibility; PARATHYROID-HORMONE; ORTHODONTIC ANCHORAGE; ALZHEIMERS-DISEASE; DENTAL IMPLANTS; MINERAL DENSITY; BONE-RESORPTION; IN-VITRO; ALLOYS; CORROSION; ALUMINUM;
D O I
10.1016/j.actbio.2018.05.020
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Superior mechanical and chemical properties of Zr(70)Ni(16)Cu(6)A(18) bulk metallic glass (BMG) demonstrate its promise as a novel biomaterial for fabrication of implants. The aim of the present study was to validate mechanical, chemical, and biological properties of Zr(70)Ni(16)Cu(6)A(18) BMG through comparison with titanium (Ti). Our data indicated higher tensile strength, lower Young's modulus, and reduced metal ion release of Zr(70)Ni(16)Cu(6)A(18) BMG compared with Ti. Biosafety of bone marrow mesenchymal cells on Zr(70)Ni(16)Cu(6)A(18) BMG was comparable to that of Ti. Next, screw-type implant prototypes made of Zr(70)Ni(16)Cu(6)A(18) BMG were fabricated and inserted into rat long bones. Zr(70)Ni(16)Cu(6)A(18) BMG implants indicated a higher removal-torque value and lower Periotest value compared with Ti implants. In addition, higher amounts of new bone formation and osseointegration were observed around Zr(70)Ni(16)Cu(6)A(18) BMG implants compared with Ti implants. Moreover, gene expression analysis displayed higher expression of osteoblast- and osteoclast-associated genes in the Zr(70)Ni(16)Cu(6)A(18) BMG group compared with the Ti group. Importantly, loading to implants upregulated bone formation, as well as osteoblast- and osteoclast-associated gene expression in the peri-implant area. No significant difference in concentrations of Ni, Al, Cu, and Zr in various organs was shown between in the Zr(70)Ni(16)Cu(6)A(18) BMG and Ti groups. Collectively, these findings suggest that Zr(70)Ni(16)Cu(6)A(18) BMG is suitable for fabricating novel implants with superior mechanical properties, biocompatibility, stability, and biosafety compared with Ti. Statement of Significance Titanium is widely used to fabricate orthopedic and dental implants. However, Titanium has disadvantages for biomedical applications in regard to strength, elasticity, and biosafety. Recently, we developed a novel hypoeutectic Zr(70)Ni(16)Cu(6)A(18) BMG, which has superior mechanical and chemical properties. However, the validity of Zr(70)Ni(16)Cu(6)A(18) BMG for biomedical application has not been cleared. The aim of the present study was to validate the mechanical, chemical, and biological properties of Zr(70)Ni(16)Cu(6)A(18) BMG for biomedical applications through comparison with Titanium. The present study clarifies that Zr(70)Ni(16)Cu(6)A(18) BMG has good mechanical properties, corrosion resistance, and osteogenic activity, which are necessary features for biomedical applications. The present study provides for the first time the superiority of Zr(70)Ni(16)Cu(6)A(18) BMG implants to Titanium implants for biomedical applications. (C) 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:505 / 517
页数:13
相关论文
共 50 条
  • [1] Mechanical properties and biocompatibility of a novel miniscrew made of Zr70Ni16Cu6Al8 bulk metallic glass for orthodontic anchorage
    Sasaki, Shutaro
    Seiryu, Masahiro
    Ida, Hiroto
    Miyashita, Shunro
    Takeshita, Nobuo
    Irie, Daiki
    Yokoyama, Yoshihiko
    Takano-Yamamoto, Teruko
    [J]. SCIENTIFIC REPORTS, 2023, 13 (01)
  • [2] Mechanical properties and biocompatibility of a novel miniscrew made of Zr70Ni16Cu6Al8 bulk metallic glass for orthodontic anchorage
    Shutaro Sasaki
    Masahiro Seiryu
    Hiroto Ida
    Shunro Miyashita
    Nobuo Takeshita
    Daiki Irie
    Yoshihiko Yokoyama
    Teruko Takano-Yamamoto
    [J]. Scientific Reports, 13
  • [3] Mechanisms of Tensile Plastic Deformation in Zr70Ni16Cu6Al8 Bulk Metallic Glass
    Tokunaga, Hitoo
    Koyama, Junpei
    Fujita, Kazutaka
    Yokoyama, Yoshihiko
    Yamasaki, Tohru
    Inoue, Akihisa
    [J]. JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2011, 75 (10) : 569 - 574
  • [4] Tensile Plastic Deformation of Zr70Ni16Cu6Al8 Bulk Metallic Glass at Cryogenic Temperature
    Tokunaga, Hitoo
    Nitta, Yuhei
    Shirota, Akinori
    Fujita, Kazutaka
    Yokoyama, Yoshihiko
    Yamasaki, Tohru
    Inoue, Akihisa
    [J]. JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2009, 73 (12) : 919 - 923
  • [5] Tensile Plastic Deformation Behavior of Zr70Ni16Cu6Al8 Bulk Metallic Glass at Cryogenic Temperature
    Tokunaga, Hitoo
    Fujita, Kazutaka
    Yokoyama, Yoshihiko
    [J]. MATERIALS TRANSACTIONS, 2012, 53 (08) : 1395 - 1399
  • [6] Effect of strain rate on tensile and compressive plastic deformation of Zr70Ni16Cu6Al8 bulk metallic glass
    Advanced Production System Eng. Course, Ube National College of Tech., Tokiwadai, Ube, 755-855, Japan
    不详
    不详
    不详
    [J]. Zairyo, 2 (118-123):
  • [7] Tensile properties of Zr70Ni16Cu6Al8 BMG at room and cryogenic temperatures
    Brennhaugen, David D. E.
    Georgarakis, Konstantinos
    Yokoyama, Yoshihiko
    Nakayama, Koji S.
    Arnberg, Lars
    Aune, Ragnhild E.
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 742 : 952 - 957
  • [8] Evaluation of Ni-free Zr-Cu-Fe-Al bulk metallic glass for biomedical implant applications
    [J]. Huang, H.-H. (hhhuang@ym.edu.tw), 1600, Elsevier Ltd (586):
  • [9] Evaluation of Ni-free Zr-Cu-Fe-Al bulk metallic glass for biomedical implant applications
    Sun, Ying-Sui
    Zhang, Wei
    Kai, Wu
    Liaw, Peter K.
    Huang, Her-Hsiung
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2014, 586 : S539 - S543
  • [10] Effects of crystallization on mechanical behavior and corrosion performance of a ductile Zr68Al8Ni8Cu16 bulk metallic glass
    Hua, Nengbin
    Liao, Zhenlong
    Wang, Qianting
    Zhang, Lei
    Ye, Youxiong
    Brechtl, Jamieson
    Liaw, Peter K.
    [J]. JOURNAL OF NON-CRYSTALLINE SOLIDS, 2020, 529