Impact of prosthetic mitral valve orientation on the ventricular flow field: Comparison using patient-specific computational fluid dynamics

被引:17
|
作者
Lantz, Jonas [1 ,2 ]
Back, Sophia [1 ,2 ]
Carlhall, Carl-Johan [2 ,3 ,4 ]
Bolger, Ann [3 ,4 ,5 ]
Persson, Anders [2 ,6 ]
Karlsson, Matts [2 ,7 ]
Ebbers, Tino [1 ,2 ]
机构
[1] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Cardiovasc Med, Linkoping, Sweden
[2] Linkoping Univ, Ctr Med Image Sci & Visualizat CMIV, Linkoping, Sweden
[3] Linkoping Univ, Dept Clin Physiol Linkoping, Linkoping, Sweden
[4] Linkoping Univ, Dept Hlth Med & Caring Sci, SE-58183 Linkoping, Sweden
[5] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
[6] Linkoping Univ, Dept Hlth Med & Caring Sci, Div Radiol, Linkoping, Sweden
[7] Linkoping Univ, Dept Management & Engn, Div Appl Thermodynam & Fluid Mech, Linkoping, Sweden
基金
瑞典研究理事会;
关键词
Computational fluid dynamics; Virtual implantation; Mitral valve; Computed tomography; 4D flow CT;
D O I
10.1016/j.jbiomech.2020.110209
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Significant mitral valve regurgitation creates progressive adverse remodeling of the left ventricle (LV). Replacement of the failing valve with a prosthesis generally improves patient outcomes but leaves the patient with non-physiological intracardiac flow patterns that might contribute to their future risk of thrombus formation and embolism. It has been suggested that the angular orientation of the implanted valve might modify the postoperative distortion of the intraventricular flow field. In this study, we investigated the effect of prosthetic valve orientation on LV flow patterns by using heart geometry from a patient with LV dysfunction and a competent native mitral valve to calculate intracardiac flow fields with computational fluid dynamics (CFD). Results were validated using in vivo 4D Flow MRI. The computed flow fields were compared to calculations following virtual implantation of a mechanical heart valve oriented in four different angles to assess the effect of leaflet position. Flow patterns were visualized in longand short-axes and quantified with flow component analysis. In comparison to a native valve, valve implantation increased the proportion of the mitral inflow remaining in the basal region and further increased the residual volume in the apical area. Only slight changes due to valve orientation were observed. Using our numerical framework, we demonstrated quantitative changes in left ventricular blood flow due to prosthetic mitral replacement. This framework may be used to improve design of prosthetic heart valves and implantation procedures to minimize the potential for apical flow stasis, and potentially assist personalized treatment planning. (c) 2020 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Patient-specific computational modelling of the mitral valve
    Kalozoumis, P.
    Morticelli, L.
    Haverich, A.
    Korossis, S.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S882 - S882
  • [2] Influence of prosthetic mitral valve orientation on left ventricular flow
    Stijnen, JMA
    van de Vosse, FN
    Baaijens, FPT
    COMPUTERS IN CARDIOLOGY 2001, VOL 28, 2001, 28 : 173 - 175
  • [3] Computational analysis of the electromechanical performance of mitral valve cerclage annuloplasty using a patient-specific ventricular model
    Lee, Kyung Eun
    Kim, Ki Tae
    Lee, Jong Ho
    Jung, Sujin
    Kim, June-Hong
    Shim, Eun Bo
    KOREAN JOURNAL OF PHYSIOLOGY & PHARMACOLOGY, 2019, 23 (01): : 63 - 70
  • [4] Patient-Specific Computational Modeling of Mitral Valve Repair Techniques
    Thuy Pham
    Kong, Fanwei
    Martin, Caitlin
    Wang, Qian
    Primiano, Charles
    McKay, Raymond
    Elefteriades, John
    Sun, Wei
    CARDIOLOGY, 2016, 134 (02) : 145 - 146
  • [5] Patient-specific LV fluid dynamics analysis to guide percutaneous mitral valve implantation
    Alharbi, Y.
    Otton, J.
    Muller, D.
    Lovell, N. H.
    Al Abed, A.
    Dokos, S.
    EUROPEAN HEART JOURNAL, 2018, 39 : 510 - 510
  • [6] Impact of leg bending in the patient-specific computational fluid dynamics of popliteal stenting
    Ferrarini, A.
    Finotello, A.
    Salsano, G.
    Auricchio, F.
    Palombo, D.
    Spinella, G.
    Pane, B.
    Conti, M.
    ACTA MECHANICA SINICA, 2021, 37 (02) : 279 - 291
  • [7] Impact of leg bending in the patient-specific computational fluid dynamics of popliteal stenting
    A. Ferrarini
    A. Finotello
    G. Salsano
    F. Auricchio
    D. Palombo
    G. Spinella
    B. Pane
    M. Conti
    Acta Mechanica Sinica, 2021, 37 : 279 - 291
  • [8] On the choice of outlet boundary conditions for patient-specific analysis of aortic flow using computational fluid dynamics
    Pirola, S.
    Cheng, Z.
    Jarral, O. A.
    O'Regan, D. P.
    Pepper, J. R.
    Athanasiou, T.
    Xu, X. Y.
    JOURNAL OF BIOMECHANICS, 2017, 60 : 15 - 21
  • [9] Patient-specific fluid simulation of transcatheter mitral valve replacement in mitral annulus calcification
    Hill, Samuel Joseph
    Young, Alistair
    Prendergast, Bernard
    Redwood, Simon
    Rajani, Ronak
    De Vecchi, Adelaide
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [10] Analysis of Patient-Specific Carotid Bifurcation Models Using Computational Fluid Dynamics
    Tu, Jiyuan
    Wong, Kelvin K. L.
    Cheung, Sherman C. P.
    Beare, Richard
    Phan, Thanh
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2011, 1 (02) : 116 - 125