LC-MS/MS coupled with immunoaffinity extraction for determination of estrone, 17β-estradiol and estrone 3-sulfate in human plasma

被引:33
|
作者
Hosogi, Jun [1 ]
Tanaka, Hideyuki [1 ]
Fujita, Kazuhiro [1 ]
Kuwabara, Takashi [1 ]
Ikegawa, Shigeo [2 ]
Kobayashi, Norihiro [3 ]
Mano, Nariyasu [4 ,5 ]
Goto, Junichi [4 ]
机构
[1] Kyowa Hakko Kirin Co Ltd, Div Res, Pharmacokinet Res Labs, Nagaizumi, Shizuoka 4118731, Japan
[2] Kinki Univ, Fac Pharmaceut Sci, Osaka 5778502, Japan
[3] Kobe Pharmaceut Univ, Higashinada Ku, Kobe, Hyogo 6588558, Japan
[4] Tohoku Univ Hosp, Dept Pharmaceut Sci, Aoba Ku, Sendai, Miyagi 9808574, Japan
[5] Tohoku Univ, Grad Sch Pharmaceut Sci, Lab Clin Pharm, Aoba Ku, Sendai, Miyagi 9808574, Japan
关键词
Estradiol; Estrone; Estrone sulfate; LC-MS/MS; Immunoaffinity extraction; TANDEM MASS-SPECTROMETRY; LIQUID-CHROMATOGRAPHY; BREAST-CANCER; HUMAN SERUM; RIA METHOD; ESTRADIOL; SULFATE; THERAPY; ASSAY;
D O I
10.1016/j.jchromb.2009.08.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Determination of estrogens in plasma is important in evaluation of effects of some anticancer drugs, such as aromatase inhibitors. However, as reported previously, high performance liquid chromatography-radio Immunoassay (HPLC-RIA) and liquid chromatography-tandem mass spectrometry (I.C-MS/MS) with chemical derivatization require complicated sample preparation In this study, a highly sensitive and simple method for determination of estrone (E1), 17 beta-estradiol (E2) and estrone 3-sulfate (EIS) in human plasma has been developed. Following diethylether extraction from plasma. analytes were purified by immunosorbents and then determined by LC-MS/MS using electrospray ionization (ESI). Immunosorbents were prepared by immobilization of specific antibodies raised against each analyte onto solid support Use of selective immunosorbents in sample preparation removed interference in plasma samples that would cause ionization suppression, and markedly improved the sensitivity of LC-MS/MS for these analytes, without derivatization. Calibration curves of each analyte showed good linearity and reproducibility over the range of 005-50 pg/injection for E1.0.2-50 pg/injection for E2 and 0.05-300 pg/injection for E1 S. respectively. The mean values of lower limits of quantification (LLOQ) in human plasma corrected by recovery of deuterated estrogens (internal standard, I S.) were 0.1892 pg/mL for E7, 0.7064 pg/mL for E2 and 0.3333 pg/mL for E1 S. respectively. These LLOQ values were comparable to those previous reported using HPLC-RIA and LC-MS/MS. Using this method, the normal levels of three estrogens in healthy female plasma (n=5) were determined. The mean values of E1, E2 and El S were 38.0 pg/mL (range 24.8-53.0).34.3 pg/ml. (22 6-46.6) anti 786 pg/mL. (163-2080), respectively The immunoaffinity LC-MS/MS described here allows sensitive and accurate quantification of E1, E2 and E1 S without laborious sample preparation (C) 2009 Elsevier B.V. All rights reserved
引用
收藏
页码:222 / 227
页数:6
相关论文
共 50 条
  • [1] Measurement of serum estradiol and estrone by LC-MS/MS.
    Nelson, RE
    Taylor, RL
    O'Kane, DJ
    Singh, RJ
    CLINICAL CHEMISTRY, 2002, 48 (06) : A132 - A132
  • [2] Separation of dansylated 17β-estradiol, 17α-estradiol, and estrone on a single HPLC column for simultaneous quantitation by LC-MS/MS
    Szarka, Szabolcs
    Vien Nguyen
    Prokai, Laszlo
    Prokai-Tatrai, Katalin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (10) : 3399 - 3406
  • [3] Determination of estrone sulfate, testosterone, androstenedione, DHEAS, cortisol, cortisone, and 17α-hydroxyprogesterone by LC-MS/MS in children and adolescents
    Ankarberg-Lindgren, Carina
    Andersson, Mats X.
    Dahlgren, Jovanna
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2020, 80 (08): : 672 - 680
  • [4] Simultaneous assay of segesterone acetate (Nestorone®), estradiol, progesterone, and estrone in human serum by LC-MS/MS
    Erikson, David W.
    Blue, Steven W.
    Fecteau, Kristopher M.
    Edelman, Alison B.
    Jensen, Jeffrey T.
    Blithe, Diana L.
    CONTRACEPTION, 2020, 102 (05) : 361 - 367
  • [5] MEASUREMENT OF ESTRONE SULFATE, ESTRADIOL-17BETA AND ESTRONE IN HUMAN PERIPHERAL PLASMA
    HAWKINS, RA
    OAKEY, RE
    JOURNAL OF ENDOCRINOLOGY, 1972, 55 (02) : R13 - R14
  • [6] Separation of dansylated 17β-estradiol, 17α-estradiol, and estrone on a single HPLC column for simultaneous quantitation by LC–MS/MS
    Szabolcs Szarka
    Vien Nguyen
    Laszlo Prokai
    Katalin Prokai-Tatrai
    Analytical and Bioanalytical Chemistry, 2013, 405 : 3399 - 3406
  • [7] LC-MS/MS simultaneous analysis of allopregnanolone, epiallopregnanolone, pregnanolone, dehydroepiandrosterone and dehydroepiandrosterone 3-sulfate in human plasma
    Lionetto, Luana
    De Andres, Fernando
    Capi, Matilde
    Curto, Martina
    Sabato, Donata
    Simmaco, Maurizio
    Bossu, Paola
    Sacchinelli, Eleonora
    Orfei, Maria Donata
    Piras, Federica
    Banaj, Nerisa
    Spalletta, Gianfranco
    BIOANALYSIS, 2017, 9 (06) : 527 - 539
  • [8] Development and validation of a liquid chromatography coupled to mass spectrometer (LC-MS) method for the simultaneous quantification of estrone-3-sulfate, progesterone, estrone and estradiol in serum of mares and American bisons
    Dufour, Patrice
    Courtois, Justine
    Seynaeve, Ysaline
    Peeters, Stephanie
    Le Goff, Caroline
    Cavalier, Etienne
    Ponthier, Jerome
    RESEARCH IN VETERINARY SCIENCE, 2021, 136 : 343 - 350
  • [9] Simultaneous Measurement of 17β-Estradiol, 17α-Estradiol and Estrone by GC–Isotope Dilution MS–MS
    Katalin Prokai-Tatrai
    Darius Bonds
    Laszlo Prokai
    Chromatographia, 2010, 71 : 311 - 315
  • [10] ESTRONE SULFATE, ESTRONE, ESTRADIOL AND ESTRIOL PLASMA LEVELS IN HUMAN PREGNANCY
    LORIAUX, DL
    LIPSETT, MB
    RUDER, HJ
    KNAB, DR
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1972, 35 (06): : 887 - +