An underfrequency load shedding scheme for high dependability and security tolerant to induction motors dynamics

被引:5
|
作者
Maresch, K. [1 ]
Marchesan, G. [2 ]
Cardoso Junior, G. [3 ]
Borges, Adriano [3 ]
机构
[1] Univ Fed Santa Maria UFSM, Programa Posgrad Engn Eletr PPGEE, Ctr Excelencia Energia & Sistemas Potencia CEESP, Lab Anal & Protecao Sistemas Eletr LAPES, Santa Maria, RS, Brazil
[2] Univ Fed Santa Maria, PPGEE, Dept Eletromecan & Sistemas Potencia DESP, CEESP,LAPES, Santa Maria, RS, Brazil
[3] Univ Fed Santa Maria, DESP, CEESP, LAPES, Santa Maria, RS, Brazil
关键词
Under-frequency load shedding; Induction motor dynamics; Discriminant functions analysis;
D O I
10.1016/j.epsr.2021.107217
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The load shedding scheme is a last resort to prevent power system collapse when the available generation is less than the load demand. The traditional load shedding schemes monitors the frequency and voltage by underfrequency and undervoltage relays and provides load cutoff until the frequency returns to a stable point of operation. The reduction of rotating inertia demands faster load shedding to meet the stability requirements. In some electrical power systems in Brazil, it was found that, in the event of opening a transmission line upstream of the load shedding substation, some under frequency relay may operate improperly. This paper proposes a new method to avoid the unwanted operation of load shedding schemes when the utility substation (source) is out of service. The proposed method monitors negative sequence voltage, frequency and its rate of change, enabling faster load shedding (high dependability) without unwanted (high security) operation when compared with traditional methods. Events were classified by linear discriminant analysis and tested in the IEEE 9 bus test system. The tests consisted of several disturbances such as loss of generation and line outages at different levels of feeder loading, reactive compensation and distributed generation. The proposed method reached a 100% rate of correct classification.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Underfrequency Load Shedding with Variable Shedding Scheme
    Tarnik, Marian
    Ernek, Martin
    Murgas, Tomas
    Murgas, Jan
    CONTROL OF POWER SYSTEMS 2018, 2018, : 6 - 9
  • [2] A NEW LOAD SHEDDING SCHEME FOR LIMITING UNDERFREQUENCY
    PRESETIJO, D
    LACHS, WR
    SUTANTO, D
    IEEE TRANSACTIONS ON POWER SYSTEMS, 1994, 9 (03) : 1371 - 1379
  • [3] An underfrequency load shedding scheme for islanded microgrids
    Ketabi, Abbas
    Fini, Masoud Hajiakbari
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 599 - 607
  • [4] A Synchrophasor Measurements based Adaptive Underfrequency Load Shedding Scheme
    Prasad, M.
    Satish, K. N.
    Kuldeep
    Sodhi, Ranjana
    2014 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2014, : 424 - 428
  • [5] A Topology-based Scheme for Adaptive Underfrequency Load Shedding
    Duong, Dinh Thuc
    Uhlen, Kjetil
    2017 IEEE MANCHESTER POWERTECH, 2017,
  • [6] An Underfrequency Load Shedding Scheme for Hybrid and Multiarea Power Systems
    Ketabi, Abbas
    Fini, Masoud Hajiakbari
    IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (01) : 82 - 91
  • [7] An Underfrequency Load Shedding Scheme with Minimal Knowledge of System Parameters
    Joe, Athbel
    Krishna, S.
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2015, 16 (01): : 33 - 46
  • [8] Underfrequency Load Shedding Scheme Using Generator Coherency Approach
    Rahman, Fathin Saifur
    Hariyanto, Nanang
    2014 IEEE WORKSHOP ON ELECTRONICS, COMPUTER AND APPLICATIONS, 2014, : 750 - 753
  • [9] An Adaptive Underfrequency Load Shedding Scheme in the Presence of Solar Photovoltaic Plants
    Chandra, Arkadipta
    Pradhan, Ashok Kumar
    IEEE SYSTEMS JOURNAL, 2021, 15 (01): : 1235 - 1244
  • [10] Revision of the underfrequency load-shedding scheme of the Slovenian power system
    Tomsic, Tomaz
    Verbic, Gregor
    Gubina, Ferdinand
    ELECTRIC POWER SYSTEMS RESEARCH, 2007, 77 (5-6) : 494 - 500