Diagnostic Accuracy of Technology-based Eye Care Services The Technology-based Eye Care Services Compare Trial Part I

被引:37
|
作者
Maa, April Y. [1 ,2 ]
Medert, Charles M. [3 ]
Lu, Xiaoqin [1 ,2 ]
Janjua, Rabeea [1 ]
Howell, Ashley, V [4 ]
Hunt, Kelly J. [4 ]
McCord, Sarah [5 ]
Giangiacomo, Annette [1 ]
Lynch, Mary G. [2 ,6 ]
机构
[1] Atlanta Vet Affairs Hlth Care Syst, TECS Div, Reg Telehlth Serv, Atlanta, GA USA
[2] Emory Univ, Sch Med, Atlanta, GA USA
[3] Univ Miami, Bascom Palmer Eye Inst, Miami, FL USA
[4] Ralph A Johnson Dept Vet Affairs, Charleston Hlth Equ & Rural Outreach Innovat Ctr, Med Ctr, Charleston, SC USA
[5] New York Eye & Ear Infirm, New York, NY 10003 USA
[6] Atlanta Vet Affairs Hlth Care Syst, Ophthalmol Div, Surg Serv, Atlanta, GA USA
关键词
DIABETIC-RETINOPATHY; OPTIC DISC; SCREENING-PROGRAM; TELEOPHTHALMOLOGY; AGREEMENT; OPHTHALMOLOGISTS; IMAGES;
D O I
10.1016/j.ophtha.2019.07.026
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: Ophthalmologic telemedicine has the ability to provide eye care for patients remotely, and many countries have used screening tele-ophthalmology programs for several years. One such initiative at the Veterans Affairs (VA) Healthcare System is Technology-based Eye Care Services (TECS). The TECS services are located in primary care clinics and provide basic screening eye care, including vision, refraction, and retinal photography. Eye care providers ("readers") review the clinical data and recommend appropriate follow-up. One of the most common referrals from TECS has been for glaucoma, and this study was powered for glaucoma/glaucoma suspect detection. The current study was undertaken to identify aspects of the protocol that could be refined to enhance accuracy. Design: Prospective comparison between the standard TECS protocol versus a face-to-face (FTF) examination on 256 patients, all of whom had no known history of significant ocular disease. Participants: Patients with no known ocular disease who were scheduled for an in-person eye appointment at the Atlanta VA. Patients underwent screening through the TECS protocol and received an FTF examination on the same day (gold standard). The TECS readers were masked to the results of the FTF examination. Main Outcome Measures: Percent agreement, kappa, sensitivity, and specificity were calculated for the TECS readers' interpretations versus the FTF examination. Results: The TECS readers showed substantial agreement for cataract (kappa >= 0.71) and diabetic retinopathy (kappa >= 0.61) and moderate to substantial agreement for glaucoma/glaucoma suspect (kappa >= 0.52) compared with an FTF examination. Age-related macular degeneration (AMD) showed moderate agreement (kappa >= 0.34). Percent agreement with the TECS protocol was high (84.3%-98.4%) for each of the disease categories. Overall sensitivity and specificity were >= 75% and >= 55%, respectively, for any diagnosis resulting in referral. Inter-reader and intra-reader agreement was substantial for most diagnoses (kappa > 0.61) with percent agreements ranging from 66% to 99%. Conclusions: Our results indicate that the standard TECS protocol is accurate when compared with an FTF examination for the detection of common eye diseases. The inclusion of additional testing such as OCT could further enhance diagnostic capability. Published by Elsevier on behalf of the American Academy of Ophthalmology
引用
收藏
页码:38 / 44
页数:7
相关论文
共 50 条
  • [1] The Impact of OCT on Diagnostic Accuracy of the Technology-Based Eye Care Services Protocol Part II of the Technology-Based Eye Care Services Compare Trial
    Maa, April Y.
    McCord, Sarah
    Lu, Xiaoqin
    Janjua, Rabeea
    Howell, Ashley, V
    Hunt, Kelly J.
    Medert, Charles M.
    Giangiacomo, Annette
    Lynch, Mary G.
    [J]. OPHTHALMOLOGY, 2020, 127 (04) : 544 - 549
  • [2] Early Experience with Technology-Based Eye Care Services (TECS)
    Maa, April Y.
    Wojciechowski, Barbara
    Hunt, Kelly J.
    Dismuke, Clara
    Shyu, Jason
    Janjua, Rabeea
    Lu, Xiaoqin
    Medert, Charles M.
    Lynch, Mary G.
    [J]. OPHTHALMOLOGY, 2017, 124 (04) : 539 - 546
  • [3] Remote eye care screening for rural veterans with Technology-based Eye Care Services: a quality improvement project
    Maa, A. Y.
    Wojciechowski, B.
    Hunt, K.
    Dismuke, C.
    Janjua, R.
    Lynch, M. G.
    [J]. RURAL AND REMOTE HEALTH, 2017, 17 (01):
  • [4] Technology-based services and applications
    Nachtrab, Michaela
    [J]. SPRACHE-STIMME-GEHOR, 2024, 48 (02): : 135 - 136
  • [5] Development of new technology-based services
    Noh, Heeyong
    Song, Youngkeun
    Park, Ae-Soon
    Yoon, Byungun
    Lee, Sungjoo
    [J]. SERVICE INDUSTRIES JOURNAL, 2016, 36 (5-6): : 200 - 222
  • [6] An application of technology-based design for exhibition services
    Hsieh, Yen-Hao
    Yuan, Soe-Tsyr
    [J]. INTERNATIONAL JOURNAL OF QUALITY AND SERVICE SCIENCES, 2016, 8 (04) : 498 - 515
  • [7] The role of design in of technology-based the development services
    Candi, Marina
    [J]. DESIGN STUDIES, 2007, 28 (06) : 559 - 583
  • [8] Technology-based interventions in health care
    Kane, J. M.
    [J]. EPIDEMIOLOGY AND PSYCHIATRIC SCIENCES, 2014, 23 (04) : 323 - 326
  • [9] Technology-based tools and services for people with dementia and carers: Mapping technology onto the dementia care pathway
    Lorenz, Klara
    Freddolino, Paul P.
    Comas-Herrera, Adelina
    Knapp, Martin
    Damant, Jacqueline
    [J]. DEMENTIA-INTERNATIONAL JOURNAL OF SOCIAL RESEARCH AND PRACTICE, 2019, 18 (02): : 725 - 741
  • [10] A System to Identify Technological Chances in Technology-Based Services
    Kim, Chulhyun
    Kim, Moon-Soo
    [J]. ADVANCED SCIENCE LETTERS, 2015, 21 (10) : 3201 - 3204