Seismic performance of deficient reinforced concrete frames retrofitted with eccentric steel braces

被引:1
|
作者
Pervez, Faisal [1 ]
Khan, Fasih Ahmed [1 ]
Alam, Bashir [1 ]
Alam, Farhan [1 ]
Ahmad, Naveed [2 ]
机构
[1] Univ Engn & Technol, Dept Civil Engn, Peshawar, Pakistan
[2] Stanford Univ, Dept Civil & Environm Engn, Stanford, CA USA
关键词
BRC frame; Deformation capacity; Response modification factor; Yield stiffness; RC FRAMES; BEHAVIOR; BUILDINGS;
D O I
10.1007/s41062-022-00934-5
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This research has carried out an experimental study on retrofitting a structure with weak beam-column joints (non-code compliant RC structures). Such structures exhibit poor performance in earthquakes and experience severe damage in the beam/column joint regions. Therefore, a new retrofitting technique is introduced by inserting inverted "V" type of eccentric steel braces to prevent brittle failure at the beam-column joints region. For experimental validation, two 1:3 reduced scaled models were prepared with/without the steel bracings and tested with the help of a seismic simulator (shake table). The 1994 Northridge acceleration time history was selected based on the requirements of regional tectonics. Load and resistant factor design procedures were adopted to design steel braces and connections. The incremental dynamic analysis technique was adopted to determine the maximum roof displacement, peak base acceleration, and base shear force values to determine seismic response and capacity curves. Seismic performance was evaluated on ductility, overstrength, response modification, and yield stiffness. The stiffness of the braced frame was improved by 195% from the as-built frame stiffness, and as a result, the roof displacement was reduced, but story shear capacity was increased from the as-built RC frame. It was observed that no considerable damages appeared after the application of 100% of the acceleration time history. Based on this experimental research, the following results were summarized: the ductility and overstrength factors were evaluated at 2.07 and 5.73, respectively. As a result, the response modification factor was calculated as 11.83, which is 75% more than the response modification factor of the as-built frame. The yield strength of the braced frame was improved by 97%. The performance of the braced frame was found to be better than that of the as-built RC frame.
引用
下载
收藏
页数:17
相关论文
共 50 条
  • [1] Seismic performance of deficient reinforced concrete frames retrofitted with eccentric steel braces
    Faisal Pervez
    Fasih Ahmed Khan
    Bashir Alam
    Farhan Alam
    Naveed Ahmad
    Innovative Infrastructure Solutions, 2022, 7
  • [2] Seismic tests on reinforced concrete and steel frames retrofitted with dissipative braces
    Molina, FJ
    Sorace, S
    Terenzi, G
    Magonette, G
    Viaccoz, B
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2004, 33 (15): : 1373 - 1394
  • [3] Experimental study on seismic performance of reinforced concrete frames retrofitted with eccentric buckling-restrained braces (BRBs)
    Yang, Yong
    Liu, Ruyue
    Xue, Yicong
    Li, Hui
    EARTHQUAKES AND STRUCTURES, 2017, 12 (01) : 79 - 89
  • [4] Eccentric steel brace retrofit for seismic upgrading of deficient reinforced concrete frames
    Ahmad, Naveed
    Masoudi, Mostafa
    BULLETIN OF EARTHQUAKE ENGINEERING, 2020, 18 (06) : 2807 - 2841
  • [5] Eccentric steel brace retrofit for seismic upgrading of deficient reinforced concrete frames
    Naveed Ahmad
    Mostafa Masoudi
    Bulletin of Earthquake Engineering, 2020, 18 : 2807 - 2841
  • [6] Rehabilitation of reinforced concrete frames with non-seismic details using eccentric steel braces
    Basit, Abdul
    Khan, Muhammad S.
    Ahmad, Naveed
    STRUCTURAL ENGINEERING AND MECHANICS, 2021, 80 (04) : 401 - 416
  • [7] Seismic performance of reinforced concrete building frames on sloping ground retrofitted with steel and reinforced concrete jacketing
    Mithu Dey
    Subrata Chakraborty
    Innovative Infrastructure Solutions, 2024, 9 (11)
  • [8] Behavior of Reinforced Concrete Frames Retrofitted by Different Configurations of Concentric Steel Braces
    Beiraghi, Hamid
    Kheyroddi, A.
    Nafechi, Z. Falaki
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2022, 46 (03) : 2039 - 2052
  • [9] Behavior of Reinforced Concrete Frames Retrofitted by Different Configurations of Concentric Steel Braces
    Hamid Beiraghi
    A. Kheyroddi
    Z. Falaki Nafechi
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2022, 46 : 2039 - 2052
  • [10] Comparison of Seismic Performance of Knee Braces in Steel Frames with Y Shaped Eccentric Braces
    Farheen, Fathima
    Akshara, S. P.
    PROCEEDINGS OF STRUCTURAL ENGINEERING AND CONSTRUCTION MANAGEMENT, SECON'19, 2020, 46 : 551 - 562