A Case Study on a Fire-Induced Collapse Accident of a Reinforced Concrete Frame-Supported Masonry Structure

被引:26
|
作者
Li, Yi [1 ]
Lu, Xinzheng [2 ]
Guan, Hong [3 ]
Ying, Mingjian [2 ]
Yan, Weiming [1 ]
机构
[1] Beijing Univ Technol, Beijing Collaborat Innovat Ctr Metropolitan Trans, Minist Educ, Key Lab Urban Secur & Disaster Engn, Beijing 100124, Peoples R China
[2] Tsinghua Univ, Dept Civil Engn, Minist Educ, Key Lab Civil Engn Safety & Durabil, Beijing 100084, Peoples R China
[3] Griffith Univ, Griffith Sch Engn, Gold Coast Campus, Southport, Qld 4222, Australia
基金
中国国家自然科学基金; 澳大利亚研究理事会;
关键词
Frame-supported masonry structure; Fire-induced collapse; Site investigation; Numerical simulation; PROGRESSIVE COLLAPSE; STEEL STRUCTURES; RESISTANCE; BUILDINGS; BEHAVIOR; DESIGN; COLUMNS; CALCULATE; TOWERS; BEAMS;
D O I
10.1007/s10694-015-0491-0
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In 2003, an 8-storey reinforced concrete (RC) frame-supported masonry structure, located in Hengyang City, China, underwent a severe fire-induced collapse accident. Information on the structure and the fire scenario is presented. It includes the design data, the site observation record of the fire incident, and the laboratory material test results. Preliminary investigation reveals that about 45.9% of the bottom storey of the RC frame experienced temperatures in excess of 800A degrees C, and its central area reached 1300A degrees C. Such a severe fire load, of fairly high temperature and large area, is thought to be the primary cause of the progressive collapse of the entire building structure. To better understand the collapse mechanism, this study presents a coupled thermo-mechanical numerical simulation of the building collapse. The actual collapse area is well reproduced by the proposed numerical model. The simulation further demonstrates that the initial damage happened to two interior columns exposed to temperature of 1300A degrees C. Such damage was also attributable to the large gravity load they carried, and the complicated nature of the local structural arrangements. The adjacent structural members were subsequently damaged, because they were also weakened by the fire, and were over-loaded by the redistributed load. Failure of the two interior columns and adjacent area eventually triggered a progressive collapse. Further, the effect of some critical factors on the collapse mechanism is discussed. On the basis of this numerical case study, practical design considerations on the key structural components, the fire compartments, and the structural robustness are given for the prevention of the fire-induced progressive collapse of RC frame structures.
引用
收藏
页码:707 / 729
页数:23
相关论文
共 50 条
  • [1] A Case Study on a Fire-Induced Collapse Accident of a Reinforced Concrete Frame-Supported Masonry Structure
    Yi Li
    Xinzheng Lu
    Hong Guan
    Mingjian Ying
    Weiming Yan
    Fire Technology, 2016, 52 : 707 - 729
  • [2] A Case Study on a Fire-Induced Collapse Accident of a Reinforced Concrete Frame-Supported Masonry Structure
    Li, Yi
    Lu, Xinzheng
    Guan, Hong
    Ying, Mingjian
    Yan, Weiming
    Fire Technology, 2016, 52 (03): : 707 - 729
  • [3] Developments and research on fire-induced progressive collapse behaviour of reinforced concrete elements and frame — a review
    Parthasarathi Narayanaswamy
    Satyanarayanan Kachabeswara Srinivasan
    Prakash Murugan
    Environmental Science and Pollution Research, 2023, 30 : 72101 - 72113
  • [4] Developments and research on fire-induced progressive collapse behaviour of reinforced concrete elements and frame - a review
    Narayanaswamy, Parthasarathi
    Srinivasan, Satyanarayanan Kachabeswara
    Murugan, Prakash
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (28) : 72101 - 72113
  • [5] Experimental study on frame-supported reinforced masonry wall-beam with double holes
    Wang, Feng-Lai
    Chen, Zai-Xian
    Yang, Gang
    Liu, Wei-Ji
    Harbin Gongye Daxue Xuebao/Journal of Harbin Institute of Technology, 2009, 41 (12): : 31 - 35
  • [6] Experimental study on the seismic behavior of a frame-supported reinforced masonry short-limb shear wall structure
    Harbin Institute of Technology, Harbin 150090, China
    Tumu Gongcheng Xuebao, 2009, 11 (71-78):
  • [7] Fire-induced spalling in reinforced concrete beams
    Kodur, Venkatesh
    Dwaikat, Monther
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2012, 165 (07) : 347 - 359
  • [8] Seismic behavior research of 1/4 scale frame-supported reinforced concrete masonry shear-wall building
    College of Civil Engineering, Hunan University, Changsha 410082, China
    不详
    Jianzhu Jiegou Xuebao, 2007, 6 (175-184):
  • [9] Fire-Induced Collapse of Automated Rack-Supported Warehouses
    Mei, Alessandro
    Orlando, Maurizio
    Salvatori, Luca
    Thiele, Klaus
    ce/papers, 2023, 6 (3-4) : 2167 - 2172
  • [10] The seismic response of 1/4-scale frame-supported reinforced masonry shear wall
    Liang, Huang
    Xiang, Gao
    Chuxian, Shi
    Shengyun, Chen
    Key Engineering Materials, 2009, 400-402 : 725 - 730