Is the reversed fourth dorsal metacarpal flap reliable?

被引:12
|
作者
Benito, JR [1 ]
Ferreres, A [1 ]
Rodriguez-Baeza, A [1 ]
Monner, J [1 ]
Paloma, V [1 ]
Serra, JMR [1 ]
机构
[1] Univ Barcelona, Hand Unit, Hosp Clin, E-08007 Barcelona, Spain
来源
关键词
D O I
10.1054/jhsb.1999.0333
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We have carried out a study to determine if a flap based on vessels in the fourth metacarpal space could be used safely, We studied ten fresh cadaver specimens and used the flap in nine patients. In the anatomical study, we confirmed the presence of a suitable artery in nine out of the ten hands, arising from a piercing artery at the metacarpal bases, running distally under the fascia, The pivot point is located at the metacarpal heads, where the artery anastomoses to palmar branches and dorsal digital branches. In the clinical setting, the flap was reliable in eight patients. There was one case of flap necrosis, The flap seems to be reliable but several technical points are stressed to avoid complications.
引用
收藏
页码:135 / 139
页数:5
相关论文
共 50 条
  • [1] The anatomic basis of the fourth dorsal metacarpal flap: A cadaveric dissection
    Yoon, Tai-Sik
    Carrera, Anna
    Benito-Ruiz, Jesus
    Ferreres, Angel
    Serra-Renom, Jose M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (05): : 711 - 716
  • [2] The reverse dorsal metacarpal artery flap in finger reconstruction: A reliable choice
    Balan, Jyoshid R.
    Mathew, Shaji
    Kumar, Pradeep
    Vardhan, Harsh
    Francis, Anto
    Aniljith, V. G.
    Gopal, Raj
    INDIAN JOURNAL OF PLASTIC SURGERY, 2018, 51 (01) : 54 - 59
  • [4] THE REVERSE DORSAL METACARPAL FLAP
    MARUYAMA, Y
    BRITISH JOURNAL OF PLASTIC SURGERY, 1990, 43 (01): : 24 - 27
  • [5] Re: The reverse dorsal metacarpal artery flap in finger reconstruction: A reliable choice
    Jain, Leena
    Kumta, Samir Madhukar
    Purohit, Shrirang Keshav
    INDIAN JOURNAL OF PLASTIC SURGERY, 2018, 51 (03) : 340 - +
  • [6] Dorsal Metacarpal Artery Flap for Resurfacing of Fourth-Degree Electrical Burns of Fingers
    Karunadasa, Kolitha Parakrama
    Beneragama, Thushan S.
    Dissanayake, Dammika A.
    Perera, Dulip
    JOURNAL OF BURN CARE & RESEARCH, 2010, 31 (04): : 674 - 674
  • [7] Reverse dorsal metacarpal osteocutaneous flap
    SantaComba, A
    Amarante, J
    Silva, A
    Rodrigues, J
    BRITISH JOURNAL OF PLASTIC SURGERY, 1997, 50 (07): : 555 - 558
  • [8] Dorsal Metacarpal Artery Flap: An Underrated Workhorse Flap for Reconstruction of Dorsal Finger Defects
    Alexander, Leon
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2020, 12 (10)
  • [9] Dorsal metacarpal island flap in syndactyly treatment
    Aydin, A
    Özden, BÇ
    ANNALS OF PLASTIC SURGERY, 2004, 52 (01) : 43 - 48
  • [10] Reverse second dorsal metacarpal artery flap for reconstruction of fourth-degree burn wounds of the hand
    Yoon, Sung W.
    Rebecca, Alanna M.
    Smith, Anthony A.
    Mazaheri, Mehdi K.
    Casey, William J., III
    JOURNAL OF BURN CARE & RESEARCH, 2007, 28 (03): : 521 - 523