Keratoconus Screening Indices and Their Diagnostic Ability to Distinguish Normal From Ectatic Corneas

被引:114
|
作者
Shetty, Rohit [1 ]
Rao, Harsha [1 ]
Khamar, Pooja [1 ]
Sainani, Kanchan [1 ]
Vunnava, Krishnapoojita [1 ]
Jayadev, Chaitra [1 ]
Kaweri, Luci [1 ]
机构
[1] Narayana Nethralaya Eye Inst, Bangalore, Karnataka, India
关键词
TOPOGRAPHY; PENTACAM;
D O I
10.1016/j.ajo.2017.06.031
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the diagnostic ability of 3 Scheimpflug devices in differentiating normal from ectatic corneas. DESIGN: Comparison of diagnostic instrument accuracy. METHODS: This study included 42 normal, 37 subclinical keratoconic, and 51 keratoconic eyes seen in a tertiary eye care institute. Keratoconus screening indices were evaluated using the Pentacam (Oculus, Wetzlar, Germany), Galilei (Ziemer, Biel, Switzerland), and Sirius (Costruzione Strumenti Oftalmici, Florence, Italy). Sensitivity, specificity, and area under receiver operating characteristic curve (AUC) were calculated. RESULTS: Highest sensitivity (100%) to diagnose keratoconus was seen for 6 parameters on Pentacam and 1 on Galilei. None of the indices in Sirius reached 100% sensitivity. For subclinical keratoconus, the highest sensitivity (100%) was seen for 2 parameters on Pentacam but for none of them on Galilei and Sirius. All parameters were strong enough to differentiate.keratoconus (AUC > 0.9). On comparing the best parameters of all 3 machines, the AUC of the Belin/Ambrosio enhanced ectasia total derivation (BAD-D) and the inferior superior value (ISV) of Pentacam were statistically similar to that of the keratoconus prediction index (KPI) and keratoconus probability (Kprob) of Galilei (P = .27) and 4.5 mm root mean square per unit area (RMS/A) back of Sirius (P = .55). When differentiating subclinical from normal corneas, BAD-D was similar to the surface regularity index (SRI) of Galilei (P = .78) but was significantly greater than the 8 mm RMS/A back of Sirius (P = .002). CONCLUSION: Keratoconus indices measured by all 3 machines can effectively differentiate keratoconus from normal corneas. However, new cutoff values might be needed to differentiate subclinical from normal corneas. (C) 2017 Elsevier Inc. All rights reserved.
引用
收藏
页码:140 / 148
页数:9
相关论文
共 21 条
  • [1] Differential molecular signature of ectatic and non-ectatic areas from Keratoconus patient corneas
    Pahuja, N.
    Kumar, N. Rajiv
    Shetty, R.
    Shroff, R.
    Ghosh, A.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [2] Differential molecular signature of ectatic and non-ectatic areas from Keratoconus patient corneas
    Pahuja, N.
    Kumar, N. Rajiv
    Shetty, R.
    Shroff, R.
    Ghosh, A.
    ACTA OPHTHALMOLOGICA, 2015, 93
  • [3] Pentacam Accuracy in Discriminating Keratoconus From Normal Corneas: A Diagnostic Evaluation Study
    Hashemi, Hassan
    Khabazkhoob, Mehdi
    Pakzad, Reza
    Bakhshi, Salomeh
    Ostadimoghaddam, Hadi
    Asaharlous, Amir
    Yekta, Reihaneh
    Aghamirsalim, Mohamadreza
    Yekta, Abbasali
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2019, 45 (01): : 46 - 50
  • [4] Diagnostic ability to distinguish high astigmatism from ectatic cornea using 2 different Scheimpflug devices.
    Henriquez, Maria
    Izquierdo, Luis
    Maldonado, Carmen
    Canola, Laura
    Cerrate, Michelle
    Hadid, Marta G.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [5] Comprehensive Assessment of Corvis ST Biomechanical Indices in Normal and Keratoconus Corneas with Reference to Corneal Enantiomorphism
    Borderie, Vincent
    Beauruel, Juliette
    Cuyaubere, Roxane
    Georgeon, Cristina
    Memmi, Benjamin
    Sandali, Otman
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [6] Extracting features from normal corneas and keratoconus based on wavelet analysis
    Yu, Jin-Hua
    Ji, Chun-Hong
    Li, Tian-Jie
    Tian, Lei
    Huang, Yi-Fei
    Wang, Yuan-Yuan
    Zheng, Yong-Ping
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 (10): : 2919 - 2926
  • [7] An Epithelial Modulation Index to Distinguish Keratoconus from Corneas with Contact Lens-Related Warpage
    Pavlatos, Elias
    Yang, Yuli
    Huang, David
    Li, Yan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [8] COMPARISON OF DESCEMETS MEMBRANES FROM NORMAL FUCHS ENDOTHELIAL DYSTROPHY AND KERATOCONUS CORNEAS
    KENNEY, M
    DEMLOW, TA
    WARING, GO
    ANATOMICAL RECORD, 1982, 202 (03): : A96 - A96
  • [9] A diagnostic biomechanical framework to distinguish keratoconus and normal eyes using air-puff applanation
    Khamar, Pooja
    Francis, Mathew
    Shroff, Rushad
    Pahuja, Natasha
    Roshan, T.
    Shetty, Rohit
    Matalia, Himanshu
    Roy, Abhijit Sinha
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [10] New artificial intelligence index based on Scheimpflug corneal tomography to distinguish subclinical keratoconus from healthy corneas
    Almeida, Gildasio Castello, Jr.
    Guido, Rodrigo Capobianco
    Balarin Silva, Henrique Monteiro
    Brandao, Cinara Cassia
    de Mattos, Luiz Carlos
    Lopes, Bernardo T.
    Machado, Aydano Pamponet
    Ambrosio, Renato, Jr.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (10): : 1168 - 1174