Patch-based generative adversarial neural network models for head and neck MR-only planning

被引:72
|
作者
Klages, Peter [1 ]
Benslimane, Ilyes [1 ]
Riyahi, Sadegh [1 ]
Jiang, Jue [1 ]
Hunt, Margie [1 ]
Deasy, Joseph O. [1 ]
Veeraraghavan, Harini [1 ]
Tyagi, Neelam [1 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Med Phys, 1275 York Ave, New York, NY 10021 USA
关键词
conditional generative adversarial networks (cGAN); CycleGAN; generative adversarial networks (GAN); MR-Guided Radiotherapy; pix2pix; synthetic CT generation; SYNTHETIC CT; RADIOTHERAPY; DELINEATION; IMAGES;
D O I
10.1002/mp.13927
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate pix2pix and CycleGAN and to assess the effects of multiple combination strategies on accuracy for patch-based synthetic computed tomography (sCT) generation for magnetic resonance (MR)-only treatment planning in head and neck (HN) cancer patients. Materials and methods Twenty-three deformably registered pairs of CT and mDixon FFE MR datasets from HN cancer patients treated at our institution were retrospectively analyzed to evaluate patch-based sCT accuracy via the pix2pix and CycleGAN models. To test effects of overlapping sCT patches on estimations, we (a) trained the models for three orthogonal views to observe the effects of spatial context, (b) we increased effective set size by using per-epoch data augmentation, and (c) we evaluated the performance of three different approaches for combining overlapping Hounsfield unit (HU) estimations for varied patch overlap parameters. Twelve of twenty-three cases corresponded to a curated dataset previously used for atlas-based sCT generation and were used for training with leave-two-out cross-validation. Eight cases were used for independent testing and included previously unseen image features such as fused vertebrae, a small protruding bone, and tumors large enough to deform normal body contours. We analyzed the impact of MR image preprocessing including histogram standardization and intensity clipping on sCT generation accuracy. Effects of mDixon contrast (in-phase vs water) differences were tested with three additional cases. The sCT generation accuracy was evaluated using mean absolute error (MAE) and mean error (ME) in HU between the plan CT and sCT images. Dosimetric accuracy was evaluated for all clinically relevant structures in the independent testing set and digitally reconstructed radiographs (DRRs) were evaluated with respect to the plan CT images. Results The cross-validated MAEs for the whole-HN region using pix2pix and CycleGAN were 66.9 +/- 7.3 vs 82.3 +/- 6.4 HU, respectively. On the independent testing set with additional artifacts and previously unseen image features, whole-HN region MAEs were 94.0 +/- 10.6 and 102.9 +/- 14.7 HU for pix2pix and CycleGAN, respectively. For patients with different tissue contrast (water mDixon MR images), the MAEs increased to 122.1 +/- 6.3 and 132.8 +/- 5.5 HU for pix2pix and CycleGAN, respectively. Our results suggest that combining overlapping sCT estimations at each voxel reduced both MAE and ME compared to single-view non-overlapping patch results. Absolute percent mean/max dose errors were 2% or less for the PTV and all clinically relevant structures in our independent testing set, including structures with image artifacts. Quantitative DRR comparison between planning CTs and sCTs showed agreement of bony region positions to The dosimetric and MAE based accuracy, along with the similarity between DRRs from sCTs, indicate that pix2pix and CycleGAN are promising methods for MR-only treatment planning for HN cancer. Our methods investigated for overlapping patch-based HU estimations also indicate that combining transformation estimations of overlapping patches is a potential method to reduce generation errors while also providing a tool to potentially estimate the MR to CT aleatoric model transformation uncertainty. However, because of small patient sample sizes, further studies are required.
引用
收藏
页码:626 / 642
页数:17
相关论文
共 50 条
  • [1] MR-Based Synthetic-CT Generation Using Generative Adversarial Network for Head and Neck MR-Only Radiotherapy
    Qi, M.
    Li, Y.
    Wu, A.
    Guo, F.
    Jia, Q.
    Zhou, L.
    Song, T.
    MEDICAL PHYSICS, 2019, 46 (06) : E112 - E112
  • [2] Robustness of Conditional Generative Adversarial Networks in Generating Head and Neck Synthetic CT Images for MR-Only Radiotherapy Treatment Planning
    Klages, P.
    Benslimane, I.
    Riyahi, S.
    Jiang, J.
    Hunt, M.
    Deasy, J.
    Veeraraghavan, H.
    Tyagi, N.
    MEDICAL PHYSICS, 2019, 46 (06) : E295 - E296
  • [3] Conditional Patch-based Generative Adversarial Network for Retinal Vessel Segmentation
    Rammy, Sadaqat Ali
    Anwar, Sadia Jabbar
    Abrar, Muhammad
    Zhang, Wu
    2019 22ND IEEE INTERNATIONAL MULTI TOPIC CONFERENCE (INMIC), 2019, : 244 - 249
  • [4] Patch-Based Generative Adversarial Network Towards Retinal Vessel Segmentation
    Abbas, Waseem
    Shakeel, Muhammad Haroon
    Khurshid, Numan
    Taj, Murtaza
    NEURAL INFORMATION PROCESSING (ICONIP 2019), PT IV, 2019, 1142 : 49 - 56
  • [5] Neural network based MR-only treatment planning for cervix cancer using low field MR images
    Buschmann, M.
    Fetty, L.
    Heilemann, G.
    Heilmann, M.
    Kuess, P.
    Georg, D.
    Nesvacil, N.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S221 - S222
  • [6] CPGAN: Conditional patch-based generative adversarial network for retinal vessel segmentation
    Rammy, Sadaqat Ali
    Abbas, Waseem
    Hassan, Naqy-Ul
    Raza, Asif
    Zhang, Wu
    IET IMAGE PROCESSING, 2020, 14 (06) : 1081 - 1090
  • [7] Abdominal Synthetic CT Generation for MR-Only Liver Radiotherapy Using Conditional Generative Adversarial Network
    Fu, J.
    Santhanam, A.
    Cao, M.
    Guo, M.
    Singhrao, K.
    Yu, V.
    Ruan, D.
    Low, D.
    Lewis, J.
    MEDICAL PHYSICS, 2018, 45 (06) : E701 - E701
  • [8] Feasibility of MR-Only Proton Therapy Planning for Head and Neck Rhabdomyosarcoma Using Transfer Learning
    Wang, C.
    Uh, J.
    Hua, C.
    Acharya, S.
    PEDIATRIC BLOOD & CANCER, 2020, 67 : S74 - S74
  • [9] A Dixon Based Pseudo-CT Generation Method for MR-Only Radiotherapy Treatment Planning of the Pelvis and Head and Neck
    Maspero, M.
    Seevinck, P. R.
    Meijer, G. J.
    Lagendijk, J. J. W.
    Viergever, M. A.
    van den Berg, C. A. T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3316 - 3316
  • [10] A Conditional Generative Adversarial Deep Neural Network for Automatic Segmentation of Head and Neck Structures
    Santhanam, A.
    Wang, J.
    Stiehl, B.
    Chin, R.
    Cao, M.
    Low, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E430 - E430