Effect of a biplanar osteotomy on primary stability following high tibial osteotomy: a biomechanical cadaver study

被引:52
|
作者
Pape, Dietrich [1 ]
Lorbach, Olaf [1 ]
Schmitz, Christian [2 ]
Busch, Lueder C. [3 ]
Van Giffen, Nicolien [1 ]
Seil, Romain [1 ]
Kohn, Dieter M. [4 ]
机构
[1] Ctr Hosp Luxembourg, Ctr Appareil Locomoteur Med Sport & Prevent, Clin Eich, L-1460 Luxembourg, Luxembourg
[2] BG Unfallklin Duisburg, D-47249 Duisburg, Germany
[3] Med Univ Lubeck, Inst Anat, D-23538 Lubeck, Germany
[4] Univ Saarland, Orthopad Univ Klin Homburg, D-66421 Homburg, Saar, Germany
关键词
Biplanar osteotomy; High tibial osteotomy; Biomechanics; Stability; Cadaver study; OPEN-WEDGE; DIFFERENT IMPLANTS; ACCURACY; RSA;
D O I
10.1007/s00167-009-0929-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Open-wedge high tibial osteotomy (HTO) is becoming increasingly popular for the treatment of varus gonarthrosis in the active patient. The various implants used in HTO differ with regard to its design, the fixation stability and osteotomy technique. It is assumed that the combination of a plate fixator with a biplanar, v-shaped osteotomy supports bone healing. So far, there are no biomechanical studies that quantify the stabilizing effect of a biplanar versus uniplanar osteotomy. We hypothesized that a significant increase in primary stability of bone-implant constructs is achieved when using a biplanar as opposed to a uniplanar osteotomy. Twenty-four fresh-frozen human tibiae were mounted in a metal cylinder, and open-wedge osteotomy (12 mm wedge size) was performed in a standardized fashion. Proximal and distal tibial segments were marked with tantalum markers of 0.8 mm diameter. Two different plates with locking screws were used for fixation: a short spacer plate (group 1, n = 12) and a plate fixator (group 2, n = 12). In six specimens of each group, a biplanar V-shaped osteotomy with a 110A degrees angulated anterior cut behind the tuberosity parallel to the ventral tibial shaft axis was performed. In the remaining six specimens of each group, a simple uniplanar osteotomy was performed in an oblique fashion. Axial compression of the tibiae was performed using a material testing machine under standardized alignment of the loading axis. Load-controlled cyclical staircase loading tests were performed. The specimens were radiographed simultaneously in two planes together with a biplanar calibration cage in front of a film plane with and without load after each subcycle. Radiostereometry allowed for serial quantification of plastic and elastic micromotion at the osteotomy site reflecting the stability provided by the combination of implant and osteotomy technique. No significant additional stabilizing effect of a biplanar osteotomy in craniocaudal and mediolateral plane was found. However, additional stability was achieved in anteroposterior (AP) and all rotational planes in those specimens fixated with a short spacer plate. In this biomechanical set-up with axial load, the additional stabilizing effect of a biplanar osteotomy did not come into effect in the presence of a long and rigid plate fixator. However, biplanar osteotomy increased the fixation stability significantly in AP and rotational planes when a short spacer plate was used. Clinically, the biplanar osteotomy promotes bone healing regardless of the implant used. Biomechanically, biplanar osteotomy is advantageous for shorter plate designs to increase primary stability of the bone-implant construct.
引用
收藏
页码:204 / 211
页数:8
相关论文
共 50 条
  • [1] Effect of a biplanar osteotomy on primary stability following high tibial osteotomy: a biomechanical cadaver study
    Dietrich Pape
    Olaf Lorbach
    Christian Schmitz
    Lüder C. Busch
    Nicolien Van Giffen
    Romain Seil
    Dieter M. Kohn
    Knee Surgery, Sports Traumatology, Arthroscopy, 2010, 18 : 204 - 211
  • [2] Biomechanical effect of fibular osteotomy on the knee joint in high tibial osteotomy: A cadaveric study
    Tanifuji, Osamu
    Mochizuki, Tomoharu
    Koga, Yoshio
    Tanabe, Yuji
    Kawashima, Hiroyuki
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2023, 34 (02) : 123 - 131
  • [3] Effect of posteriorly inclined sagittal osteotomy on posterior tibial slope in biplanar medial opening wedge high tibial osteotomy: a case series study
    Oktem, Umut
    Dedeogullari, Emin Suha
    Bingol, Izzet
    Kamaci, Saygin
    Bozkurt, Ibrahim
    Ocguder, Durmus Ali
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [4] The biplanar open wedge high tibial osteotomy preserving the tibial tubercle
    Hopwood, Sam
    Khan, Wasim
    Agarwal, Sanjeev
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2016, 21 (06) : 786 - 790
  • [5] High tibial osteotomy - primary stability of several implants
    Flamme, CH
    Kohn, D
    Kirsch, L
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1999, 137 (01): : 48 - 53
  • [6] Rehabilitation Following High Tibial Osteotomy
    Aalderink, Kristopher J.
    Shaffer, Michael
    Amendola, Annunziato
    CLINICS IN SPORTS MEDICINE, 2010, 29 (02) : 291 - +
  • [7] Biplanar high tibial osteotomy for the combined correction of varus and posterior tibial slope malalignment
    Mueller, Sebastian
    Frosch, Karl-Heinz
    Frings, Jannik
    Berninger, Markus
    Krause, Matthias
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2023, 109 (04)
  • [8] BIOMECHANICAL COMPARISON BETWEEN HIGH TIBIAL OSTEOTOMY (HTO) AND COMBINED HTO AND FIBULAR OSTEOTOMY
    HEFZY, MS
    SADDEMI, SR
    CHENG, G
    HOEFLINGER, M
    MILEM, C
    FROGAMENI, AD
    CLINICAL BIOMECHANICS, 1994, 9 (05) : 284 - 290
  • [9] Primary stability of different implants used in conjunction with high tibial osteotomy
    Flamme, CH
    Kohn, D
    Kirsch, L
    Hurschler, C
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1999, 119 (7-8) : 450 - 455
  • [10] Primary stability of different implants used in conjunction with high tibial osteotomy
    C. H. Flamme
    D. Kohn
    L. Kirsch
    C. Hurschler
    Archives of Orthopaedic and Trauma Surgery, 1999, 119 : 450 - 455