Effects of x-ray spectrum on the NPS of a computed radiography system

被引:2
|
作者
Fetterly, KA [1 ]
Hangiandreou, NJ [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Rochester, MN 55905 USA
关键词
computed radiography; noise power spectrum; diagnostic radiology; phantom; x-ray spectrum;
D O I
10.1117/12.384542
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this work was to determine the effects of various incident x-ray beam spectra on the measured noise power spectrum (NPS) of a computed radiography (CR) image acquisition device. A CR phosphor was uniformly exposed to 1 mR with x-ray beams whose peak tube potentials were 70, 95, and 120 kVp that were filtered by various thicknesses of a "patient equivalent phantom" (PEP; 2% aluminum, 98% acrylic by thickness), aluminum, and copper. From the uniform exposure images, NPS curves were calculated and their integral values were computed. The integral noise values were found to vary substantially as a function of x-ray beam spectral content. A simple x-ray beam and filter model that accounted for the shape of the filtered x-ray spectra and the mass energy absorption coefficient of the storage phosphor verified the qualitative behavior of the integral NPS values corresponding to changes in the incident x-ray beam used. The x-ray beam and filter combinations of 70 kVp and 10.1 cm of PEP filtration and 120 kVp and 20.2 cm of PEP filtration were chosen as standard techniques for evaluating clinical imaging systems. These two combinations represent a relatively low, clinically relevant CR noise (integral NPS = 2.6x10(-6) mm) technique and a relatively high, clinically relevant CR noise (integral NPS 3.3x10(-6) mm) technique.
引用
收藏
页码:632 / 639
页数:8
相关论文
共 50 条
  • [1] Effects of x-ray spectra on the DQE of a computed radiography system
    Fetterly, KA
    Hangiandreou, NJ
    [J]. MEDICAL PHYSICS, 2001, 28 (02) : 241 - 249
  • [2] X-ray Digital Radiography and Computed Tomography
    Morigi, Maria Pia
    Albertin, Fauzia
    [J]. JOURNAL OF IMAGING, 2022, 8 (05)
  • [3] Computed radiography X-ray exposure trends
    Seibert, JA
    Shelton, DK
    Moore, EH
    [J]. ACADEMIC RADIOLOGY, 1996, 3 (04) : 313 - 318
  • [4] X-ray Sources for Adaptive Radiography and Computed Tomography
    Kutsaev, S., V
    Agustsson, R.
    Arodzero, A.
    Boucher, S.
    Burstein, P.
    Smirnov, A. Yu
    [J]. 25TH INTERNATIONAL CONFERENCE ON THE APPLICATION OF ACCELERATORS IN RESEARCH AND INDUSTRY (CAARI 2018), 2019, 2160
  • [5] Investigation of optimum X-ray beam tube voltage and filtration for chest radiography with a computed radiography system
    Moore, C. S.
    Beavis, A. W.
    Saunderson, J. R.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2008, 81 (970): : 771 - 777
  • [6] FLASH X-RAY APPARATUS WITH SPECTRUM CONTROL FUNCTIONS FOR MEDICAL USE AND FUJI COMPUTED RADIOGRAPHY
    ISOBE, H
    SATO, E
    HAYASI, Y
    SUZUKI, M
    ARIMA, H
    HOSHINO, F
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1985, 491 : 168 - 179
  • [7] Scale analysis using X-ray microfluorescence and computed radiography
    Candeias, J. P.
    de Oliveira, D. F.
    dos Anjos, M. J.
    Lopes, R. T.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 408 - 411
  • [8] Integrated system simulation in X-ray radiography
    Kwan, TJT
    Mathews, AR
    Christenson, PJ
    Snell, CM
    [J]. COMPUTER PHYSICS COMMUNICATIONS, 2001, 142 (1-3) : 263 - 269
  • [9] Digital X-ray radiogrammetry (DXR) on hand X-ray images using computed radiography (CR).
    Hussain, AM
    Baadegaard, N
    Wendt, O
    Rosholm, A
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2001, 16 : S457 - S457
  • [10] X-ray energy spectrum estimation based on a virtual computed tomography system
    Higuchi, Takayuki
    Haga, Akihiro
    [J]. BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2023, 9 (02):