Colour Doppler imaging and fluorescein filling defects of the optic disc in normal tension glaucoma

被引:58
|
作者
Plange, N [1 ]
Remky, A [1 ]
Arend, O [1 ]
机构
[1] Univ Klinikum Aachen, Augenklin, D-52057 Aachen, Germany
关键词
D O I
10.1136/bjo.87.6.731
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aim: To investigate the relation between blood flow parameters of the retrobulbar vessels measured by means of colour Doppler imaging (CDI) and fluorescein filling defects of the optic nerve head in patients with normal tension glaucoma (NTG) and control subjects. Methods: 29 patients with NTG and 29 age and sex matched control subjects were included in this study. Blood flow velocities - peak systolic velocity (PSV), end diastolic velocity (EDV), and resistive indices ( RI) of the ophthalmic artery (OA), the central retinal artery (CRA), and of the temporal and nasal short posterior ciliary arteries (TPCA, NPCA) - were measured with CDI. Fluorescein angiograms were performed with a scanning laser ophthalmoscope. The extent of absolute fluorescein filling defects of the optic nerve head in relation to the optic nerve head was assessed. Results: The PSV of the OA, the PSV and EDV of the CRA, and of the TPCA and NPCA were significantly reduced in NTG ( p< 0.05). The RI of the CRA, the TPCA and NPCA were significantly increased in NTG ( p< 0.01). The optic nerve head fluorescein filling defects were significantly larger in NTG ( p< 0.01). The filling defects were significantly negatively correlated ( p< 0.05) with the PSV and EDV of the CRA (PSVCRA: r= - 0.41; EDVCRA: r= - 0.34), with the PSV and EDV of the NPCA (PSVNPCA: r= - 0.34; EDVNPCA: r = - 0.38), and with the EDV of the TPCA ( r = - 0.29). A significant positive correlation ( p< 0.05) was found with the RI of both PCAs (RINPCA: r= 0.28; RITPCA: r= 0.29). Conclusion: Patients with NTG had reduced blood flow velocities and higher resistive indices in most retrobulbar vessels. Optic nerve head fluorescein filling defects were larger compared to controls. The filling defects were correlated with end diastolic velocities and resistive indices of the PCAs and with blood flow velocities of the CRA. Capillary loss of the optic nerve head may be related to higher downstream resistance and reduced blood flow velocities of the retrobulbar vessels.
引用
收藏
页码:731 / 736
页数:6
相关论文
共 50 条
  • [1] Color doppler imaging and fluorescein filling defects of the optic nerve head in normal tension glaucoma
    Plange, NH
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U63 - U63
  • [2] Absolute filling defects of the optic disc in fluorescein angiograms in glaucoma a retrospective clinical study
    Plange, N
    Remky, A
    Arend, O
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2001, 218 (04) : 214 - 221
  • [3] Fluorescein filling defects of the optic nerve head in normal tension glaucoma, primary open-angle glaucoma, ocular hypertension and healthy controls
    Plange, NH
    Kaup, M
    Remky, A
    Arend, O
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U446 - U446
  • [4] Fluorescein filling defects of the optic nerve head in normal tension glaucoma, primary open-angle glaucoma, ocular hypertension and healthy controls
    Plange, N
    Kaup, M
    Huber, K
    Remky, A
    Arend, O
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2006, 26 (01) : 26 - 32
  • [5] Optic disc findings in normal tension glaucoma
    Yamazaki, Y
    Hayamizu, F
    Miyamoto, S
    Nakagami, T
    Tanaka, C
    Inui, S
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 1997, 41 (04) : 260 - 267
  • [6] OPTIC DISK IN GLAUCOMA - TOPOGRAPHY AND EXTENT OF FLUORESCEIN FILLING DEFECTS
    FISHBEIN, SL
    SCHWARTZ, B
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1977, 95 (11) : 1975 - 1979
  • [7] INCREASED FLUORESCEIN FILLING DEFECTS IN THE WALL OF THE OPTIC DISK CUP IN GLAUCOMA
    ADAM, G
    SCHWARTZ, B
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1980, 98 (09) : 1590 - 1592
  • [8] Pseudodoubling of the optic disc: A colour Doppler imaging study
    Cellini, M
    Alessandrini, A
    Bernabini, B
    Merlo, D
    [J]. OPHTHALMOLOGICA, 2003, 217 (05) : 370 - 372
  • [9] Performance of colour Doppler imaging discriminating normal tension glaucoma from healthy eyes
    N Plange
    M Kaup
    A Weber
    A Harris
    K O Arend
    A Remky
    [J]. Eye, 2009, 23 : 164 - 170
  • [10] Performance of colour Doppler imaging discriminating normal tension glaucoma from healthy eyes
    Plange, N.
    Kaup, M.
    Weber, A.
    Harris, A.
    Arend, K. O.
    Remky, A.
    [J]. EYE, 2009, 23 (01) : 164 - 170