Research on the Performance of Low Voltage Ride-Through for Doubly Fed Induction Generator Excited by Two-Stage Matrix Converter

被引:0
|
作者
Deng, Wenlang [1 ]
Chen, Zhiyong [1 ]
Zhou, Liming [1 ]
Yang, Yu [1 ]
机构
[1] Xiangtan Univ, Coll Informat Engn, Xiangtan 411105, Peoples R China
关键词
Doubly Fed Induction Generator; Two-Stage Matrix Converter; Space Vector Modulation; Grid Fault; Low Voltage Ride-Through; DFIG;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel algorithm of dual space vector modulation (SVM) for two-stage matrix converter (TSMC) is proposed, which does not calculate real-time modulation factor of rectifier stage. Utilizing grid voltage oriented vector control strategy, decoupling control for active and reactive power generated by doubly fed induction generator (DFIG) is proposed. Then the model of grid-connection wind energy conversion system (WECS) consisting of doubly fed induction generator (DFIG) excited by TSMC is built up using MATLAB/SIMULINK. Finally, performances of low voltage ride-through (LVRT) for WECS using proposal control strategy under grid fault are illustrated by simulation. And results indicate: I. transient performance of LVRT for WECS during grid fault is good; 2. active and reactive power generated by DFIG supplying to grid never occur long-time oscillation after grid fault clearance; 3. proposed control strategy promotes dynamic and steady-state performances of WECS.
引用
收藏
页码:1447 / 1452
页数:6
相关论文
共 50 条
  • [1] A low voltage ride-through of strategy for doubly fed induction generator
    Yu, Lan
    Chen, Guocheng
    Song, Xiaoliang
    Cao, Dapeng
    Wu, Guoxiang
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2010, 25 (09): : 170 - 175
  • [2] New low voltage ride-through structure for doubly fed induction generator
    Jiang, S. (jsd1210@sohu.com), 1600, Science Press (35):
  • [3] Low voltage ride-through control strategy of doubly fed induction generator
    Zhang, Yang
    Huang, Keyuan
    Huang, Shoudao
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 : 153 - 158
  • [4] Symmetrical Low Voltage Ride-Through of the Brushless Doubly-Fed Induction Generator
    Shao, Shiyi
    Long, Teng
    Abdi, Ehsan
    McMahon, Richard
    Wu, Yunxiang
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011,
  • [5] Low Voltage Ride-Through Control of Doubly-Fed Induction Generator at Synchronism
    Binh, N. V.
    Hofmann, W.
    2014 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2014, : 803 - 809
  • [6] Review of low voltage ride-through technology of doubly-fed induction generator
    Niu, Lele
    Wang, Xiao
    Wu, Linlin
    Yang, Feng
    Xu, Man
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3106 - 3108
  • [7] Low-voltage ride-through performance of doubly-fed induction generator based on three-level converter excitation
    Cheng, M. (chengmengzeng@126.com), 1600, Electric Power Automation Equipment Press (32):
  • [8] Dynamic Characteristic Analysis of Doubly-fed Induction Generator Low Voltage Ride-through
    Shi, L.
    Chen, N.
    Lu, Q.
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT C, 2012, 16 : 1526 - 1534
  • [9] Study of Low-Voltage Ride-Through Performance for Wind Power Generation with Doubly Fed Induction Generator
    Hirawata, Ryoya
    Kai, Takaaki
    ELECTRICAL ENGINEERING IN JAPAN, 2013, 185 (01) : 17 - 26
  • [10] Fault Ride-Through of Doubly-Fed Induction Generator with Converter Protection Schemes
    Yang, Jin
    Dorrell, David G.
    Fletcher, John E.
    2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 1211 - +