Development of multiplex real-time PCR assays for differential detection of capripoxvirus, parapoxvirus and foot-and-mouth disease virus

被引:2
|
作者
Das, Amaresh [1 ]
Wang, Yin [2 ]
Babiuk, Shawn [3 ]
Bai, Jianfa [2 ]
Dodd, Kimberly [1 ]
Jia, Wei [1 ]
机构
[1] Plum Isl Anim Dis Ctr, Foreign Anim Dis Diagnost Lab, NVSL, APHIS,USDA, Orient, NY USA
[2] Kansas State Univ, Kansas State Vet Diagnost Lab, Manhattan, KS 66506 USA
[3] Natl Ctr Foreign Anim Dis, Canadian Food Inspect Agcy, Winnipeg, MB, Canada
关键词
capripoxvirus; differential detection; foot‐ and‐ mouth disease virus; multiplex real‐ time PCR; parapoxvirus;
D O I
10.1111/tbed.14099
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
This study reports the development of multiplex real-time PCR assays for differential detection of capripoxvirus (CaPV), parapoxvirus (PaPV) and foot-and-mouth disease virus (FMDV) in sheep, goats and cattle. Three multiplex assays were developed, a capripox (CaP) rule-out assay for simultaneous detection and differentiation of CaPV and PaPV, a FMD rule-out assay for simultaneous detection and differentiation of FMDV and PaPV, and a FMD/CaP rule-out assay for simultaneous detection and differentiation of CaPV, PaPV and FMDV. All multiplex assays included beta-actin gene ACTB as an internal positive control to monitor PCR inhibition and accuracy of nucleic acid extractions. The optimized assays were highly specific to the target viruses (CaPV, PaPV and FMDV) with no cross-reactivity against other viruses that cause similar clinical signs. Using positive control plasmids as template, the limit of detection (LOD) of the multiplex assays were estimated as 2 CaPV, 7 PaPV and 15 FMDV copies per assay. The amplification efficiency (AE) and correlation coefficient (R-2), estimated from the standard curves (Ct vs. log(10) template dilution), were 94%-106% and >0.99, respectively, for CaP and FMD rule-out assays, 96%-116% (AE) and >0.98 (R-2), respectively, for CaP/FMD rule-out assays and 91%-102% and >0.99, respectively, for the corresponding singleplex assays. The diagnostic sensitivity (DSe) of the multiplex assays was assessed on 35 CaPV and 39 FMDV clinical specimens from experimentally infected (CS-E) animals, and 29 CaPV (LSDV), 28 FMDV and 36 PaPV clinical specimens from naturally infected (CS-N) animals; all tested positive (DSe 100%) except two CS-E FMDV specimens that were tested negative by FMD rule-out and the corresponding singleplex (FMDV) assays (37/39; DSe 95%). The newly developed multiplex assays offer a valuable tool for differential detection of clinically indistinguishable CaPV, PaPV and FMDV in suspected animals and animals with mixed infections.
引用
收藏
页码:1326 / 1337
页数:12
相关论文
共 50 条
  • [1] Development and evaluation of multiplex real-time RT-PCR assays for the detection and differentiation of foot-and-mouth disease virus and Seneca Valley virus 1
    Wang, Yin
    Das, Amaresh
    Zheng, Wanglong
    Porter, Elizabeth
    Xu, Lizhe
    Noll, Lance
    Liu, Xuming
    Dodd, Kimberly
    Jia, Wei
    Bai, Jianfa
    TRANSBOUNDARY AND EMERGING DISEASES, 2020, 67 (02) : 604 - 616
  • [2] RAPID DETECTION AND QUANTIFICATION OF FOOT-AND-MOUTH DISEASE VIRUS BY A REAL-TIME REVERSE TRANSCRIPTION PCR
    Niedbalski, Wieslaw
    Kesy, Andrzej
    BULLETIN OF THE VETERINARY INSTITUTE IN PULAWY, 2010, 54 (01) : 3 - 7
  • [3] Fluorescence-based multiplex real-time RT-PCR arrays for the detection and serotype determination of foot-and-mouth disease virus
    Tam, Stanley
    Clavijo, Alfonso
    Engelhard, Eric K.
    Thurmond, Mark C.
    JOURNAL OF VIROLOGICAL METHODS, 2009, 161 (02) : 183 - 191
  • [4] Development and evaluation of tailored specific real-time RT-PCR assays for detection of foot-and-mouth disease virus serotypes circulating in East Africa
    Bachanek-Bankowska, Katarzyna
    Mero, Herieth R.
    Wadsworth, Jemma
    Mioulet, Valerie
    Sallu, Raphael
    Belsham, Graham J.
    Kasanga, Christopher J.
    Knowles, Nick J.
    King, Donald P.
    JOURNAL OF VIROLOGICAL METHODS, 2016, 237 : 114 - 120
  • [5] Utility of automated real-time RT-PCR for the detection of foot-and-mouth disease virus excreted in milk
    Reid, SM
    Parida, S
    King, DP
    Hutchings, GH
    Shaw, AE
    Ferris, NP
    Zhang, ZD
    Hillerton, JE
    Paton, DJ
    VETERINARY RESEARCH, 2006, 37 (01) : 121 - 132
  • [6] Diagnosis of foot-and-mouth disease by real-time fluorogenic PCR assay
    Reid, SM
    Ferris, NP
    Hutchings, GH
    Zhang, Z
    Belsham, GJ
    Alexandersen, S
    VETERINARY RECORD, 2001, 149 (20) : 621 - 623
  • [7] Development and evaluation of multiplex RT-LAMP assays for rapid and sensitive detection of foot-and-mouth disease virus
    Yamazaki, Wataru
    Mioulet, Valerie
    Murray, Lee
    Madi, Mikidache
    Haga, Takeshi
    Misawa, Naoaki
    Horii, Yoichiro
    King, Donald P.
    JOURNAL OF VIROLOGICAL METHODS, 2013, 192 (1-2) : 18 - 24
  • [8] Development of a novel quantitative real-time RT-PCR assay for the simultaneous detection of all serotypes of Foot-and-mouth disease virus
    T. B. Rasmussen
    Å. Uttenthal
    K. de Stricker
    S. Belák
    T. Storgaard
    Archives of Virology, 2003, 148 : 2005 - 2021
  • [9] Development of a novel quantitative real-time RT-PCR assay for the simultaneous detection of all serotypes of Foot-and-mouth disease virus
    Rasmussen, TB
    Uttenthal, Å
    de Stricker, K
    Belák, S
    Storgaard, T
    ARCHIVES OF VIROLOGY, 2003, 148 (10) : 2005 - 2021
  • [10] Robust Real-Time Reverse Transcription-PCR for Detection of Foot-and-Mouth Disease Virus Neutralizing Carryover Contamination
    Hwang, Ji-Hyeon
    Shin, Yong-Keol
    Park, So-Yeon
    Kim, Jeesoo
    Kim, Su-Mi
    Kim, Byounghan
    Park, Jong-Hyeon
    Lee, Jong-Soo
    Lee, Kwang-Nyeong
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (01) : 216 - 219