Self-reported continuous positive airway pressure device compliance of patients with obstructive sleep apnoea syndrome

被引:0
|
作者
Uzer, Fatih [1 ]
Okur, Ummuhan [1 ]
Cilli, Aykut [1 ]
机构
[1] Akdeniz Univ, Dept Resp Dis, Antalya, Turkey
关键词
Adherence; compliance; continuous positive airway pressure; obstructive sleep apnea syndrome; positional; rapid eye movement; LONG-TERM COMPLIANCE; NASAL CPAP; ADHERENCE; THERAPY;
D O I
10.4103/ijrc.ijrc_135_20
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Patients with obstructive sleep apnoea syndrome (OSAS) are often prescribed the use of continuous positive airway pressure (CPAP) devices to overcome obstruction during sleep. We aimed at assessing the adherence rates to CPAP therapy in two clinical subtypes of OSAS. Patients and Methods: Patients diagnosed with positional or rapid eye movement related OSAS using polysomnography were included. Patients were contacted by telephone calls to collect data. Inclusion criteria were age >18 years, a total apnea-hypopnea index (AHI) >5, and a physician recommendation to initiate therapy with a CPAP device. Patients were excluded if they had known neurological disorders, were unwilling to answer all questions and had no recommendation to use CPAP therapy. Results: A total of 286 patients, 99 females (34.6%) and 187 males (65.4%), with a mean age of 56.5 +/- 11.3 years were included. There were 134 (46.9%) CPAP users and 152 (53.1%) CPAP nonusers. Reasons for not using the CPAP device included unwillingness to use the device (n = 73, 48%), reduced patient comfort due to noise, hose, or air pressure (n = 31, 20.3%), reimbursement problems (n = 38, 25%), and reasons such as recovery or operation (n = 10, 6.5%). Age, duration of use/months, number of nights per week during which the device was used and the mean number of hours per night were not significantly different between OSAS types (P > 0.05), while the mean AHI and body mass index were significantly different between OSAS types (P < 0.05). Conclusion: A significant proportion of OSAS patients do not use CPAP devices due to various reasons. Adherence to CPAP therapy was not significantly different between groups.
引用
收藏
页码:221 / 225
页数:5
相关论文
共 50 条
  • [1] CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) COMPLIANCE IN OBSTRUCTIVE SLEEP APNOEA (OSA)
    Myat, T.
    Srikantha, S.
    Phillips, C.
    Cistulli, P.
    RESPIROLOGY, 2014, 19 : 129 - 129
  • [2] Positive Airway Pressure Device Compliance of the Patients with Obstructive Sleep Apnea Syndrome
    Boyaci, Hasim
    Gacar, Kubra
    Baris, Serap Argun
    Basyigit, Ilknur
    Yildiz, Fusun
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2013, 22 (06): : 809 - 815
  • [3] Continuous positive airway pressure for metabolic syndrome in obstructive sleep apnoea
    Mohan, Alladi
    Vengamma, Bhuma
    NATIONAL MEDICAL JOURNAL OF INDIA, 2012, 25 (04): : 222 - 224
  • [4] Are symptoms of obstructive sleep apnoea related to good continuous positive airway pressure compliance?
    Kaewkes, Chaiwat
    Sawanyawisuth, Kittisak
    Sawunyavisuth, Bundit
    ERJ OPEN RESEARCH, 2020, 6 (03) : 1 - 4
  • [5] COMPLIANCE OF CONTINUOUS POSITIVE AIRWAY PRESSURE (CPAP) IN OBSTRUCTIVE SLEEP APNOEA AMONG HOSPITAL PUTRAJAYA PATIENTS
    Kugan, R.
    Syisy, A. J.
    Singh, M. Balwinder
    SLEEP MEDICINE, 2019, 64 : S204 - S205
  • [6] Predicting optimal continuous positive airway pressure in Japanese patients with obstructive sleep apnoea syndrome
    Akahoshi, Toshiki
    Akashiba, Tsuneto
    Kawahara, Seiji
    Uematsu, Akihito
    Nagaoka, Kenichi
    Kiyofuji, Kouji
    Okamoto, Naoki
    Hattori, Tomohiro
    Takahashi, Noriaki
    Hashimoto, Shu
    RESPIROLOGY, 2009, 14 (02) : 245 - 250
  • [7] Long-term benefits in self-reported health status of nasal continuous positive airway pressure therapy for obstructive sleep apnoea
    Jenkinson, C
    Davies, RJO
    Mullins, R
    Stradling, JR
    QJM-MONTHLY JOURNAL OF THE ASSOCIATION OF PHYSICIANS, 2001, 94 (02): : 95 - 99
  • [8] Continuous positive airway pressure in heart failure patients with obstructive sleep apnoea
    Ferrier, K. A.
    Neill, A. M.
    O'Meeghan, T.
    Richards, M.
    Campbell, A. J.
    INTERNAL MEDICINE JOURNAL, 2008, 38 (11) : 829 - 836
  • [9] Continuous positive airway pressure requirements in patients with tetraplegia and obstructive sleep apnoea
    Le Guen, M. C.
    Cistulli, P. A.
    Berlowitz, D. J.
    SPINAL CORD, 2012, 50 (11) : 832 - 835
  • [10] EFFECTIVENESS OF CONTINUOUS POSITIVE AIRWAY PRESSURE ON BLOOD PRESSURE IN PATIENTS WITH OBSTRUCTIVE SLEEP APNOEA
    Zhao Qing
    Liu Zhihong
    Doug, Mcevoy
    Luo Qin
    Zhao Zhihui
    Zhang Hongliang
    Wang Yong
    HEART, 2010, 96 : A183 - A183