IMPROVED BEAMFORMER WITH WEIGHTED SOURCE REGION SUPPRESSION FOR COHERENT MEG SOURCE LOCALIZATION

被引:3
|
作者
Zhang, Junpeng [1 ]
Yao, Dezhong [1 ]
机构
[1] Univ Elect Sci & Technol China, Minist Educ, Sch Life Sci & Technol, Key Lab NeuroInformat, Chengdu 610054, Peoples R China
基金
中国国家自然科学基金;
关键词
MEG inverse problem; Beamformer; Neuromagnetic signal processing; AEF; ASSEP; SOURCE MODEL; RECONSTRUCTION;
D O I
10.4015/S1016237210001955
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Beamformer is one of the main techniques for spatio-temporal neuroelectromagnetic source reconstruction. However, the classical Beamformer is extremely sensitive to strongly coherent sources, thereby encountering difficulty in localizing the highly correlated bilateral auditory cortices in auditory evoked field (AEF) or auditory steady state evoked potential. The multiple constrained minimum-variance Beamformer with coherent source region suppression (Beamformer-CS) can potentially overcome such difficulties. However, when coherent interferer is located close to the edges of the suppression region, Beamformer-CS has localization bias and the closer it is, the larger it will be. Here, we present an improved Beamformer-CS that can localize coherent sources with much less localization bias, especially in the case of the interferer close to the edges of the suppression region. First, based on approximate information about source energy distribution from other neuroimaging techniques, a region encompassing the coherent interfering sources is defined. Then, the dominant eigenvectors of the lead field matrix, weighted using source energy information obtained by other imaging method, for the suppression region is incorporated into Beamformer design as hard null constraints. Such weighting strategy is able to improve the localization performance. Simulation test shows that, compared to Beamformer-CS, the new weighting approach is of much smaller localization bias, sharper peak of the estimated sources, more robust against noise, and less sensitiveness to the number of the eigenvector components for the suppression region, as is also confirmed by real AEF data test.
引用
收藏
页码:239 / 248
页数:10
相关论文
共 50 条
  • [1] Comparison of beamformer implementations for MEG source localization
    Jaiswal, Amit
    Nenonen, Jukka
    Stenroos, Matti
    Gramfort, Alexandre
    Dalal, Sarang S.
    Westner, Britta U.
    Litvak, Vladimir
    Mosher, John C.
    Schoffelen, Jan-Mathijs
    Witton, Caroline
    Oostenveld, Robert
    Parkkonen, Lauri
    [J]. NEUROIMAGE, 2020, 216
  • [2] MEG SOURCE LOCALIZATION USING A FREQUENCY BEAMFORMER
    Thompson, Elizabeth A.
    Holland, Scott K.
    Xiang, Jing
    Wang, Yingying
    [J]. 2010 IEEE 36TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2010,
  • [3] Frequency-spatial beamformer for MEG source localization
    Thompson, Elizabeth A.
    Xiang, Jing
    Wang, Yingying
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2015, 18 : 263 - 273
  • [4] Localization of coherent sources by simultaneous MEG and EEG beamformer
    Jun Hee Hong
    Minkyu Ahn
    Kiwoong Kim
    Sung Chan Jun
    [J]. Medical & Biological Engineering & Computing, 2013, 51 : 1121 - 1135
  • [5] Localization of coherent sources by simultaneous MEG and EEG beamformer
    Hong, Jun Hee
    Ahn, Minkyu
    Kim, Kiwoong
    Jun, Sung Chan
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2013, 51 (10) : 1121 - 1135
  • [6] COHERENT MEG/EEG SOURCE LOCALIZATION IN TRANSFORMED DATA SPACE
    Zhang, Junpeng
    Dalal, Sarang S.
    Nagarajan, Srikantan S.
    Yao, Dezhong
    [J]. BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2010, 22 (05): : 351 - 365
  • [7] Modified beamformers for coherent source region suppression
    Dalal, Sarang S.
    Sekihara, Kensuke
    Nagarajan, Srikantan S.
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (07) : 1357 - 1363
  • [8] A weighted MVDR beamformer based on SVM learning for sound source localization
    Salvati, Daniele
    Drioli, Carlo
    Foresti, Gian Luca
    [J]. PATTERN RECOGNITION LETTERS, 2016, 84 : 15 - 21
  • [9] DIRECT INTERFERENCE SUPPRESSION IN EEG/MEG DIPOLE SOURCE LOCALIZATION
    Wu, Shun Chi
    Swindlehurst, A. Lee
    Yao, Yu Chen
    [J]. 2010 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2010, : 574 - 577
  • [10] EEG and MEG source localization
    Rampp S.
    [J]. Zeitschrift für Epileptologie, 2018, 31 (2): : 109 - 112