Beyond the False Negative Rate: Development of Quality Indicators for Sentinel Lymph Node Biopsy in Breast Cancer

被引:14
|
作者
Quan, May Lynn [1 ]
Wells, Bryan J. [1 ]
McCready, David [2 ]
Wright, Frances C. [1 ]
Fraser, Novlette [1 ]
Gagliardi, Anna R. [1 ]
机构
[1] Univ Toronto, Dept Surg, Sunnybrook Hlth Sci Ctr, Toronto, ON, Canada
[2] Univ Toronto, Dept Surg, Princess Margaret Hosp, Toronto, ON, Canada
关键词
MODIFIED DELPHI APPROACH; 20-YEAR FOLLOW-UP; AMERICAN-SOCIETY; PHASE-III; OF-CARE; TRIAL; DISSECTION; RESECTION; SURGERY; MASTECTOMY;
D O I
10.1245/s10434-009-0658-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. Sentinel lymph node biopsy (SNLB) has been adopted as the standard method of axillary staging for women with clinically node-negative early-stage breast cancer. The false negative rate as a quality indicator is impractical given the need for a completion axillary dissection to calculate. The objective of this study was to develop practical quality indicators for SLNB using an expert consensus method and to determine if they were feasible to measure. Materials and Methods. We used a modified Delphi consensus process to develop quality indicators for SLNB. A multidisciplinary expert panel reviewed potential indicators extracted from the medical literature to select quality indicators that were relevant and measurable. Feasibility was determined by abstracting the quality indicator variables from a retrospective chart review. Results. The expert panel prioritized 11 quality indicators as benchmarks for assessing the quality of surgical care in SNLB. Nine of the indicators were measurable at the chart or institutional level. Conclusions. A systematic evidence-and consensus-based approach was used to develop measurable quality indicators that could be used by practicing surgeons and administrators to evaluate performance of SLNB in breast cancer. Conclusions. A systematic evidence- and consensus-based approach was used to develop measurable quality indicators that could be used by practicing surgeons and administrators to evaluate performance of SLNB in breast cancer.
引用
收藏
页码:579 / 591
页数:13
相关论文
共 50 条
  • [1] Beyond the false negative rate: Development of quality indicators for sentinel lymph node biopsy in breast cancer
    Quan, M.
    Wright, F. C.
    McCready, D. R.
    Wells, B. J.
    Gagliardi, A.
    ANNALS OF SURGICAL ONCOLOGY, 2009, 16 : 43 - 43
  • [2] Beyond the False Negative Rate: Development of Quality Indicators for Sentinel Lymph Node Biopsy in Breast Cancer
    May Lynn Quan
    Bryan J. Wells
    David McCready
    Frances C. Wright
    Novlette Fraser
    Anna R. Gagliardi
    Annals of Surgical Oncology, 2010, 17 : 579 - 591
  • [3] The Number of Removed Lymph Nodes for an Acceptable False Negative Rate in Sentinel Lymph Node Biopsy for Breast Cancer
    Koo, Bon Young
    Jeong, Seong Gu
    Eom, Tae Ik
    Kang, Hee Joon
    Kim, Lee Su
    JOURNAL OF BREAST CANCER, 2009, 12 (02) : 100 - 105
  • [4] False negative sentinel lymph node biopsy; follow up of 391 sentinel lymph node negative breast cancer patients
    van Wely, B. J.
    Strobbe, L. J.
    Smidt, M. L.
    de Kievit, I. M.
    ANNALS OF SURGICAL ONCOLOGY, 2007, 14 (02) : 45 - 45
  • [5] Factors associated with false-negative rate of sentinel lymph node biopsy in breast cancer patients
    Hazel Chua, Joyce
    Chan, Valerie
    Ang, Samuel
    Chua, Derrick
    Torillo, Maila
    Tan, Benito
    ANNALS OF SURGICAL ONCOLOGY, 2018, 25 : 417 - 417
  • [6] Sentinel lymph node biopsy for breast cancer: Impact of the number of sentinel nodes removed on the false-negative rate
    Wong, SL
    Edwards, MJ
    Chao, C
    Tuttle, TM
    Noyes, RD
    Carlson, DJ
    Cerrito, PB
    McMasters, KM
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2001, 192 (06) : 684 - 689
  • [7] False-negative frozen section of sentinel lymph node biopsy for breast cancer
    Holck, S
    Galatius, H
    Engel, U
    Wagner, F
    Hoffmann, J
    BREAST, 2004, 13 (01): : 42 - 48
  • [8] Commentary on "The Number of Removed Lymph Nodes for an Acceptable False Negative Rate in Sentinel Node Biopsy for Breast Cancer"
    Nam, Seok Jin
    Lee, Se Kyung
    JOURNAL OF BREAST CANCER, 2009, 12 (03) : 227 - 228
  • [9] Sentinel lymph node biopsy for breast cancer: Impact of the number of sentinel nodes removed on the false-negative rate - Reply
    Wong, SL
    McMasters, KM
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2001, 192 (06) : 690 - 691
  • [10] Prospective study found that peripheral lymph node sampling reduced the false-negative rate of sentinel lymph node biopsy for breast cancer
    Chao Han
    Ben Yang
    WenShu Zuo
    YanSong Liu
    Gang Zheng
    Li Yang
    MeiZhu Zheng
    Chinese Journal of Cancer, 2016, 35 (06) : 63 - 68