Pulsed and continuous light UV LED: microbial inactivation, electrical, and time efficiency

被引:49
|
作者
Sholtes, Kari [1 ]
Linden, Karl G. [1 ]
机构
[1] Univ Colorado Boulder, Dept Civil Environm & Architectural Engn, Boulder, CO USA
关键词
Disinfection; Bacteria; Bacteriophage; UV LED wavelengths; Drinking water; IODIDE-IODATE ACTINOMETERS; ULTRAVIOLET-LIGHT; EMITTING-DIODES; WATER DISINFECTION; ESCHERICHIA-COLI; PSEUDOMONAS-AERUGINOSA; DOSE DETERMINATION; DARK REPAIR; IRRADIATION; PHOTOREACTIVATION;
D O I
10.1016/j.watres.2019.114965
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Ultraviolet light emitting diodes (UV LEDs) have increasing applications in the inactivation of microorganisms in water, air, food, and on surfaces. System designers currently have metrics for comparison of the microbial and energy efficiency of UV LEDs, but these have not included a time component. Without including the time efficiency of a UV LED, neither the fluence-basis nor the electrical-basis of comparison clarifies which UV LED wavelength and operating condition is optimal for a design space. This research explores microbial inactivation of UV LEDs at various wavelengths under continuous and pulsing operating conditions. Planktonic microorganisms of relevance to public water supplies and UV system design are included: E. coli and MS-2 for benchmarking against previous studies and P. aeruginosa which has not been studied in pulsed systems or for continuous and combined UV LED wavelengths. Pulsing UV LEDs at various duty rates (percent of cycle spent on) and frequencies (number of cycles per second) does not result in a statistically significant disinfection performance difference over the continuous light operation at that respective wavelength. UV LEDs emitting at peak wavelengths corresponding to the peak action spectrum of a microorganism are optimal on a fluence-basis, but these are typically less electrically efficient UV LEDs. System designers can compare the normalized microbial inactivation, electrical, and time efficiencies (E-NETO) of various UV LEDs; E-NETO >= 1 for a pulsing condition ensures equal or improved efficiency compared to the continuous light condition while expanding the lifetime of the UV LED and decreasing the size or cost of associated power supplies. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Efficiency of pulsed UV light for microbial decontamination of food powders
    Fine, F
    Gervais, P
    [J]. JOURNAL OF FOOD PROTECTION, 2004, 67 (04) : 787 - 792
  • [2] Pulsed Light Technology for Microbial Inactivation
    Endarko
    Maclean, M.
    Timoshkin, I. V.
    MacGregor, S. J.
    Anderson, J. G.
    [J]. UPEC: 2009 44TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, 2009, : 82 - 85
  • [3] Characterization of pulsed light for microbial inactivation
    Cassar, Joshua R.
    Mills, Edward W.
    Demirci, Ali
    [J]. JOURNAL OF FOOD ENGINEERING, 2022, 334
  • [4] Comparison of sterilization efficiency of pulsed and continuous UV light using tunable frequency UV system
    Luo, Wei
    Chen, Anjun
    Chen, Min
    Dong, Wei
    Hou, Xiaoyan
    [J]. INNOVATIVE FOOD SCIENCE & EMERGING TECHNOLOGIES, 2014, 26 : 220 - 225
  • [5] Pulsed UV-light inactivation of poliovirus and adenovirus
    Lamont, Y.
    Rzezutka, A.
    Anderson, J. G.
    MacGregor, S. J.
    Given, M. J.
    Deppe, C.
    Cook, N.
    [J]. LETTERS IN APPLIED MICROBIOLOGY, 2007, 45 (05) : 564 - 567
  • [6] Pulsed-UV light inactivation of Cryptosporidium parvum
    Soo-Ung Lee
    Migyo Joung
    Dong-Jin Yang
    Soon-Ho Park
    Sun Huh
    Woo-Yoon Park
    Jae-Ran Yu
    [J]. Parasitology Research, 2008, 102 : 1293 - 1299
  • [7] Pulsed-UV light inactivation of Cryptosporidium parvum
    Lee, Soo-Ung
    Joung, Migyo
    Yang, Dong-Jin
    Park, Soon-Ho
    Huh, Sun
    Park, Woo-Yoon
    Yu, Jae-Ran
    [J]. PARASITOLOGY RESEARCH, 2008, 102 (06) : 1293 - 1299
  • [8] Comparison of UV-LED treatments at 255 and 281 nm in continuous-flow on bacterial inactivation, quality, nutrients and electrical efficiency in beverages
    Popovic, Vladimir
    Reman, Julia
    Koutchma, Tatiana
    [J]. JOURNAL OF FOOD ENGINEERING, 2023, 357
  • [9] Protocol for Determining Ultraviolet Light Emitting Diode (UV-LED) Fluence for Microbial Inactivation Studies
    Kheyrandish, Ataollah
    Mohseni, Madjid
    Taghipour, Fariborz
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2018, 52 (13) : 7390 - 7398
  • [10] MICROBIAL INACTIVATION USING PULSED LIGHT- A REVIEW
    Kundwal, Moses Elisha
    Lani, Mohd Nizam
    Tamuri, Abd Rahman
    [J]. JURNAL TEKNOLOGI, 2015, 77 (13): : 99 - 109