Effect of dose reduction on image registration and image quality for cone-beam CT in radiotherapy

被引:1
|
作者
Loutfi-Krauss, B. [1 ]
Koehn, J. [1 ]
Bluemer, N. [1 ]
Freundl, K. [2 ]
Koch, T. [2 ]
Kara, E. [1 ]
Scherf, C. [1 ]
Roedel, C. [1 ]
Ramm, U. [1 ]
Licher, J. [1 ]
机构
[1] Univ Frankfurt Klinikum, Klin Strahlentherapie & Onkol, D-60590 Frankfurt, Germany
[2] Sozialstiftung Bamberg MVZ Bruderwald, Klin & Praxis Radioonkol & Strahlentherapie, D-96049 Bamberg, Germany
关键词
Radiotherapy; Cone-beam computed tomography; Image quality; Image registration; Radiation dose; SOFT-TISSUE REGISTRATION; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; GUIDED RADIOTHERAPY; CANCER INCIDENCE; RISK; RECONSTRUCTION; DOSIMETRY; SYSTEM;
D O I
10.1007/s00066-014-0750-x
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction The additional radiation exposure applied to patients undergoing cone-beam computed tomography (CBCT) for image registration in radiation therapy is of great concern. Since a decrease in CBCT dose is linked to a degradation of image quality, the consequences of dose reduction on the registration process have to be investigated. Material and methods This paper examines image quality and registration of low-contrast structures on an Elekta XVI for the two treatment areas prostate and chest while gradually decreasing the mAs per frame and the number of projections per CBCT to achieve dose reduction. Results Ideal results for image quality were obtained for 1.6 mAs/frame and 377 projections in prostate scans and 0.63 mAs/frame and 440 projections in chest images. Lower as well as higher total mAs lead to a decrease in image quality. In spite of poor image quality, registration can be successfully performed even for lowest possible settings. Conclusion The results for registration allow an extensive dose reduction in both treatment areas. Very low mAs, however, do not qualify for clinical use because subjective judgment of the registration process is impossible. Compared to default presets the use of settings for acceptable image quality already permit a decrease in exposure of about 40 % (29.0 to 16.7 mGy) in prostate scans and 60 % (18.3 to 7.7 mGy) in chest scans.
引用
收藏
页码:192 / 200
页数:9
相关论文
共 50 条
  • [1] Image Quality and Dose Measurement for Partial Cone-Beam CT
    Abouei, E.
    Ford, N.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 143 - 143
  • [2] Integration of PET-CT and cone-beam CT for image-guided radiotherapy with high image quality and registration accuracy
    Wu, T. -H.
    Liang, C. -H.
    Wu, J. -K.
    Lien, C. -Y.
    Yang, B. -H.
    Huang, Y. -H.
    Lee, J. J. S.
    [J]. JOURNAL OF INSTRUMENTATION, 2009, 4
  • [3] Deformable image registration in cone-beam CT images for image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Zhu, X.
    Garden, A.
    Ahamad, A.
    Ang, K.
    Mohan, R.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 1995 - 1995
  • [4] Image Quality QA for Three Radiotherapy Cone-Beam CT Systems
    Doemer, A.
    Perera, H.
    Gingold, E.
    Liu, H.
    Fu, L.
    Harrison, A.
    Yu, Y.
    Xiao, Y.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Image quality and dose for a multisource cone-beam CT extremity scanner
    Gang, Grace J.
    Zbijewski, Wojciech
    Mahesh, Mahadevappa
    Thawait, Gaurav
    Packard, Nathan
    Yorkston, John
    Demehri, Shadpour
    Siewerdsen, Jeffrey H.
    [J]. MEDICAL PHYSICS, 2018, 45 (01) : 144 - 155
  • [6] Patient dose in KV cone-beam CT image-guided radiotherapy
    Islam, M
    Purdie, T
    Moseley, D
    Alasti, H
    Norrlinger, B
    Sharpe, M
    Siewerdsen, J
    Jaffray, D
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1830 - 1830
  • [7] Deformable image registration for cone-beam CT (CBCT) images for implemantion of image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Ahamad, A.
    Zhu, X. R.
    Garden, A. S.
    Ang, K. K.
    Mohan, R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S647 - S648
  • [8] Effect of dose reduction on image registration and image quality for cone-beam CT in radiotherapy [Effekt einer Dosisreduktion auf Bildregistrierung und Bildqualität für eine Kegelstrahl-CT in der Strahlentherapie]
    Loutfi-Krauss B.
    Köhn J.
    Blümer N.
    Freundl K.
    Koch T.
    Kara E.
    Scherf C.
    Rödel C.
    Ramm U.
    Licher J.
    [J]. Strahlentherapie und Onkologie, 2015, 191 (2) : 192 - 200
  • [9] Optimization of Patient dose and Image registration of cone-beam CT in radiation therapy Routines
    Loutfi-Krauss, B.
    Licher, J.
    Koch, N.
    Koehn, J.
    Scherf, C.
    Kara, E.
    Ramm, U.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 : 39 - 39
  • [10] A comparison of dose reduction methods on image quality for cone beam CT
    Webb, R.
    Buckley, L. A.
    [J]. MEDICAL PHYSICS, 2014, 41 (08) : 23 - 23