ATLAS Tile Calorimeter calibration and monitoring systems

被引:0
|
作者
Cortes-Gonzalez, Arely [1 ]
机构
[1] CERN, European Org Nucl Res CERN, CH-1211 Geneva 23, Switzerland
关键词
D O I
10.1051/epjconf/201817001003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The ATLAS Tile Calorimeter is the central section of the hadronic calorimeter of the ATLAS experiment and provides important information for reconstruction of hadrons, jets, hadronic decays of tau leptons and missing transverse energy. This sampling calorimeter uses steel plates as absorber and scintillating tiles as active medium. The light produced by the passage of charged particles is transmitted by wavelength shifting fibres to photomultiplier tubes, located in the outer part of the calorimeter. Neutral particles may also produce a signal after interacting with the material and producing charged particles. The readout is segmented into about 5000 cells, each of them being read out by two photomultipliers in parallel. To calibrate and monitor the stability and performance of each part of the readout chain during the data taking, a set of calibration systems is used. This comprises Cesium radioactive sources, Laser, charge injection elements and an integrator based readout system. Information from all systems allows to monitor and equalise the calorimeter response at each stage of the signal production, from scintillation light to digitisation. Calibration runs are monitored from a data quality perspective and used as a cross-check for physics runs. The data quality efficiency achieved during 2016 was 98.9 %. These calibration and stability of the calorimeter reported here show that the TileCal performance is within the design requirements and has given essential contribution to reconstructed objects and physics results.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] ATLAS Tile Calorimeter Calibration and Monitoring Systems
    Marjanovic, Marija
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (07) : 1228 - 1235
  • [2] ATLAS Tile calorimeter calibration and monitoring systems
    Chomont, Arthur
    [J]. 17TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2016), 2017, 928
  • [3] Calibration and monitoring systems of the ATLAS tile hadron calorimeter
    Boumediene, D.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 718 : 66 - 68
  • [4] Calibration and monitoring of the ATLAS Tile calorimeter
    Carvalho, J.
    [J]. Calorimetry in High Energy Physics, 2006, 867 : 385 - 392
  • [5] Time calibration and monitoring in the ATLAS Tile Calorimeter
    Polacek, Stanislav
    [J]. PARTICLES AND NUCLEI INTERNATIONAL CONFERENCE 2021, PANIC2021, 2021,
  • [6] ATLAS Tile Calorimeter time calibration, monitoring and performance
    Davidek, T.
    [J]. 17TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2016), 2017, 928
  • [7] The Monitoring and Calibration Web Systems for the ATLAS Tile Calorimeter Data Quality Analysis
    Sivolella, A.
    Maidantchik, C.
    Ferreira, F.
    [J]. INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS 2012 (CHEP2012), PTS 1-6, 2012, 396
  • [8] Calibration and Performance of the ATLAS Tile Calorimeter
    Petukhova, Krystsina
    [J]. 4TH INTERNATIONAL CONFERENCE ON PARTICLE PHYSICS AND ASTROPHYSICS (ICPPA-2018), 2019, 1390
  • [9] Time calibration, monitoring and performance of the ATLAS Tile Calorimeter in Run 2
    Mihule, Kristina
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1048
  • [10] ATLAS Tile calorimeter calibration and PMT response
    Boumediene, D.
    [J]. JOURNAL OF INSTRUMENTATION, 2020, 15 (04)