Comparison of ultrasound B-mode, strain imaging, Acoustic Radiation Force Impulse displacement and shear wave velocity imaging using real time clinical breast images

被引:0
|
作者
Manickam, Kavitha [1 ]
Machireddy, Ramasubba Redd [1 ]
Raghawan, Bagyam [2 ]
机构
[1] Indian Inst Technol Madras, Madras 600036, Tamil Nadu, India
[2] Apollo Specialty Hosp, Madras 600035, Tamil Nadu, India
来源
MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY | 2016年 / 9790卷
关键词
Shear wave velocity imaging; ARFI displacement imaging; strain imaging; ELASTOGRAPHY; TISSUES;
D O I
10.1117/12.2217250
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
It has been observed that many pathological process increase the elastic modulus of soft tissue compared to normal. In order to image tissue stiffness using ultrasound, a mechanical compression is applied to tissues of interest and local tissue deformation is measured. Based on the mechanical excitation, ultrasound stiffness imaging methods are classified as compression or strain imaging which is based on external compression and Acoustic Radiation Force Impulse (ARFI) imaging which is based on force generated by focused ultrasound. When ultrasound is focused on tissue, shear wave is generated in lateral direction and shear wave velocity is proportional to stiffness of tissues. The work presented in this paper investigates strain elastography and ARFI imaging in clinical cancer diagnostics using real time patient data. Ultrasound B-mode imaging, strain imaging, ARFI displacement and ARFI shear wave velocity imaging were conducted on 50 patients (31 Benign and 23 malignant categories) using Siemens 52000 machine. True modulus contrast values were calculated from the measured shear wave velocities. For ultrasound B-mode, ARFI displacement imaging and strain imaging, observed image contrast and Contrast to Noise Ratio were calculated for benign and malignant cancers. Observed contrast values were compared based on the true modulus contrast values calculated from shear wave velocity imaging. In addition to that, student unpaired t-test was conducted for all the four techniques and box plots are presented. Results show that, strain imaging is better for malignant cancers whereas ARFI imaging is superior than strain imaging and B-mode for benign lesions representations.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Measurement of Shear Wave Velocity Using Acoustic Radiation Force Impulse Imaging is not Hampered by Previous Use of Ultrasound Contrast Agents
    Cui, X. W.
    Pirri, C.
    Ignee, A.
    De Molo, C.
    Hirche, T. O.
    Schreiber-Dietrich, D. G.
    Dietrich, C. F.
    ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2014, 52 (07): : 649 - 653
  • [2] Real-time acoustic radiation force impulse imaging
    Pinton, GF
    McAleavey, SA
    Dahl, JJ
    Nightingale, KR
    Trahey, GE
    MEDICAL IMAGING 2005: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2005, 5750 : 226 - 235
  • [3] Reproducibility of Shear Wave Velocity Measurements by Acoustic Radiation Force Impulse Imaging of the Liver A Study in Healthy Volunteers
    Guzman-Aroca, Florentina
    Reus, Manuel
    Berna-Serna, Juan D.
    Serrano, Laura
    Serrano, Cristina
    Gilabert, Amparo
    Cepero, Angela
    JOURNAL OF ULTRASOUND IN MEDICINE, 2011, 30 (07) : 975 - 979
  • [4] Conventional ultrasound, ultrasound elasticity imaging, and acoustic radiation force impulse imaging for prediction of malignancy in breast masses
    Gong, Jing-Jing
    Wan, Zhao-Xia
    Yao, Ming-Hua
    Zhao, Li-Xia
    Xu, Guang
    Liu, Hui
    Wu, Rong
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2016, 9 (05): : 8108 - 8117
  • [5] Comparison of strain elastography, point shear wave elastography using acoustic radiation force impulse imaging and 2D-shear wave elastography for the differentiation of thyroid nodules
    Kyriakidou, Georgia
    Friedrich-Rust, Mireen
    Bon, Dimitra
    Sircar, Ishani
    Schrecker, Christopher
    Bogdanou, Dimitra
    Herrmann, Eva
    Bojunga, Joerg
    PLOS ONE, 2018, 13 (09):
  • [6] Comparison of the Reliability of Acoustic Radiation Force Impulse Imaging and Supersonic Shear Imaging in Measurement of Liver Stiffness
    Woo, Hyunsik
    Lee, Jae Young
    Yoon, Jeong Hee
    Kim, Won
    Cho, Belong
    Choi, Byung Ihn
    RADIOLOGY, 2015, 277 (03) : 881 - 886
  • [7] PRELIMINARY RESULTS OF ACOUSTIC RADIATION FORCE IMPULSE (ARFI) ULTRASOUND IMAGING OF BREAST LESIONS
    Meng, Wei
    Zhang, Guangchen
    Wu, Changjun
    Wu, Guozhu
    Song, Yan
    Lu, Zhaoling
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (09): : 1436 - 1443
  • [8] Acoustic radiation force impulse imaging with Virtual Touch (TM) tissue quantification: mean shear wave velocity of malignant and benign breast masses
    Wojcinski, Sebastian
    Brandhorst, Kathrin
    Sadigh, Gelareh
    Hillemanns, Peter
    Degenhardt, Friedrich
    INTERNATIONAL JOURNAL OF WOMENS HEALTH, 2013, 5 : 619 - 627
  • [9] B-Mode and Acoustic Radiation Force Impulse (ARFI) Imaging of Prostate Zonal Anatomy: Comparison with 3T T2-Weighted MR Imaging
    Palmeri, Mark L.
    Miller, Zachary A.
    Glass, Tyler J.
    Garcia-Reyes, Kirema
    Gupta, Rajan T.
    Rosenzweig, Stephen J.
    Kauffman, Christopher
    Polascik, Thomas J.
    Buck, Andrew
    Kulbacki, Evan
    Madden, John
    Lipman, Samantha L.
    Rouze, Ned C.
    Nightingale, Kathryn R.
    ULTRASONIC IMAGING, 2015, 37 (01) : 22 - 41
  • [10] Diagnostic Value of Elastography Using Acoustic Radiation Force Impulse Imaging and Strain Ratio for Breast Tumors
    Kim, Yoon Seok
    Park, Jung Gu
    Kim, Beom Su
    Lee, Chung Han
    Ryu, Dong Won
    JOURNAL OF BREAST CANCER, 2014, 17 (01) : 76 - 82