Worldwide, glaucoma and age-related macular degeneration (AMD) cause 12.3% and 8.7% of the cases of blindness and/or vision loss, respectively. According to a 5-year study of Medicare beneficiaries, patients who undergo a regular eye screening, experience less decline of vision than those who had less-frequent examinations. A computer-based screening of retinopathies can be highly cost-effective and efficient; however, most auto-screening software address only one eye disease, limiting their clinical utility and cost-effectiveness. Therefore, we propose a computer-based retinopathy screening system for detection of AMD and glaucoma by integrating information from retinal fundus images and clinical data. First, the retinal image analysis algorithms were developed using Transfer Learning approach to determine presence or absence of the eye disease. The clinical data was then utilized to improve disease detection performance where the image-analysis based algorithms provided sub-optimal classification. The results for binary detection (present/absent) of AMD and Glaucoma were compared with the ground truth provided by a certified retinal reader. We applied the proposed method to a dataset of 304 retinal images with AMD, 299 retinal images with Glaucoma, and 2,341 control retinal images. The algorithms demonstrated sensitivity/specificity of 100%/99.5% for detection of any AMD, 82%/70% for detection of referable AMD, and 75%/81% for detection of referable Glaucoma. The automated detection results agree well with the ground truth suggesting its potential in screening for AMD and Glaucoma.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Computer Aided Detection Of Age Related Macular Degeneration In Retinal Images
    Calik, Esra
    Dogan, Buket
    Ucan, Osman Nuri
    2015 23RD SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2015, : 807 - 810
  • [2] Automatic detection of age-related macular degeneration pathologies in retinal fundus images
    Guven, Aysegul
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2013, 16 (04) : 425 - 434
  • [3] Towards automatic detection of age-related macular degeneration in retinal fundus images
    Liang, Ziyang
    Wong, Damon W. K.
    Liu, Jiang
    Chan, Kap Luk
    Wong, Tien Yin
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4100 - 4103
  • [4] Inner retinal layer comparisons of eyes with exudative age-related macular degeneration and eyes with age-related macular degeneration and glaucoma
    Ulfah Rimayanti
    Yoshiaki Kiuchi
    Ken Yamane
    Miftahul Akhyar Latief
    Hideki Mochizuki
    Junko Hirata
    Tomoyuki Akita
    Junko Tanaka
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 563 - 570
  • [5] Inner retinal layer comparisons of eyes with exudative age-related macular degeneration and eyes with age-related macular degeneration and glaucoma
    Rimayanti, Ulfah
    Kiuchi, Yoshiaki
    Yamane, Ken
    Latief, Miftahul Akhyar
    Mochizuki, Hideki
    Hirata, Junko
    Akita, Tomoyuki
    Tanaka, Junko
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (04) : 563 - 570
  • [6] Age-Related Macular or Retinal Degeneration?
    Galuszka, Michalina
    Pojda-Wilczek, Dorota
    Karska-Basta, Izabella
    MEDICINA-LITHUANIA, 2023, 59 (05):
  • [7] Computer-based test to measure optimal visual acuity in age-related macular degeneration
    Gonzalez, Esther G.
    Tarita-Nistor, Luminita
    Markowitz, Samuel N.
    Steinbach, Martin J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (10) : 4838 - 4845
  • [8] Glaucoma and age-related macular degeneration intricacy
    Valtot, F.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2008, 31 (06): : 55 - 60
  • [9] A COMPARISION OF OCT AND RETINAL FUNDUS IMAGES FOR AGE-RELATED MACULAR DEGENERATION
    Arabi, Punal. M.
    Krishna, Nanditha
    Deepa, Vamsha N.
    Ashwini, V
    Prathibha, H. M.
    2017 8TH INTERNATIONAL CONFERENCE ON COMPUTING, COMMUNICATION AND NETWORKING TECHNOLOGIES (ICCCNT), 2017,
  • [10] Automatic segmentation of age-related macular degeneration in retinal fundus images
    Koese, Cemal
    Sevik, Ugur
    Gencalioglu, Okyay
    COMPUTERS IN BIOLOGY AND MEDICINE, 2008, 38 (05) : 611 - 619