Handheld motion stabilized laser speckle imaging

被引:22
|
作者
Lertsakdadet, Ben [1 ,2 ]
Dunn, Cody [1 ,2 ,3 ]
Bahani, Adrian [1 ,2 ]
Crouzet, Christian [1 ,2 ]
Choi, Bernard [1 ,2 ,3 ,4 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, 1002 Hlth Sci Rd, Irvine, CA 92612 USA
[2] Univ Calif Irvine, Dept Biomed Engn, 3120 Nat Sci 2, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Edwards Lifesci Ctr Adv Cardiovasc Technol, 2400 Engn Hall, Irvine, CA 92697 USA
[4] Univ Calif Irvine, Dept Surg, 333 City Blvd West,Suite 1600, Orange, CA 92868 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
BLOOD-FLOW; PHOTODYNAMIC THERAPY; SFDI;
D O I
10.1364/BOE.10.005149
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Laser speckle imaging (LSI) is a wide-field, noninvasive optical technique that allows researchers and clinicians to quantify blood flow in a variety of applications. However, traditional LSI devices are cart or tripod based mounted systems that are bulky and potentially difficult to maneuver in a clinical setting. We previously showed that the use of a handheld LSI device with the use of a fiducial marker (FM) to account for motion artifact is a viable alternative to mounted systems. Here we incorporated a handheld gimbal stabilizer (HGS) to produce a motion stabilized LSI (msLSI) device to further improve the quality of data acquired in handheld configurations. We evaluated the msLSI device in vitro using flow phantom experiments and in vivo using a dorsal window chamber model. For in vitro experiments, we quantified the speckle contrast of the FM (K-FM) using the mounted data set and tested 80% and 85% of K-FM as thresholds for useable images (K-FM, (Mounted, 80%) and K-FM,K- Mounted,K- 85%). Handheld data sets using the msLSI device (stabilized handheld) and handheld data sets without the HGS (handheld) were collected. Using K-FM,K- Mounted,K- 80% and K-FM,K- Mounted,K- 85% as the threshold, the number of images above the threshold for stabilized handheld (38 +/- 7 and 10 +/- 2) was significantly greater (p = 0.031) than for handheld operation (16 +/- 2 and 4 +/- 1). We quantified a region of interest within the flow region (K-FLOW), which led to a percent difference of 8.5% +/- 2.9% and 7.8% +/- 3.1% between stabilized handheld and handheld configurations at each threshold. For in vivo experiments, we quantified the speckle contrast of the window chamber (KWC) using the mounted data set and tested 80% of K-WC (K-WC,K- Mounted,K- 80%). Stabilized handheld operation provided 53 +/- 24 images above K-WC,K- Mounted,K- 80%, while handheld operation provided only 23 +/- 13 images. We quantified the speckle flow index (SFI) of the vessels and the background to calculate a signal-to-background ratio (SBR) of the window chamber. Stabilized handheld operation provided a greater SBR (2.32 +/- 0.29) compared to handheld operation (1.83 +/- 0.21). Both the number of images above threshold and SBR were statistically significantly greater in the stabilized handheld data sets (p = 0.0312). These results display the improved usability of handheld data acquired with an msLSI device. (C) 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:5149 / 5158
页数:10
相关论文
共 50 条
  • [1] Prediction of motion artifacts caused by translation in handheld laser speckle contrast imaging
    Chizari, Ata
    Tsong, Wilson
    Knop, Tom
    Steenbergen, Wiendelt
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2023, 28 (04)
  • [2] Correcting for motion artifact in handheld laser speckle images
    Lertsakdadet, Ben
    Yang, Bruce Y.
    Dunn, Cody E.
    Ponticorvo, Adrien
    Crouzet, Christian
    Bernal, Nicole
    Durkin, Anthony J.
    Choi, Bernard
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (03)
  • [3] Handheld, point-of-care laser speckle imaging
    Farraro, Ryan
    Fathi, Omid
    Choi, Bernard
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (09)
  • [4] HANDHELD LASER SPECKLE IMAGING SYSTEM FOR NEONATAL BLOOD FLOW IMAGING
    Farraro, Ryan
    Fathi, Omid
    Choi, Bernard
    [J]. LASERS IN SURGERY AND MEDICINE, 2015, 47 : 9 - 10
  • [5] Exploration of movement artefacts in handheld laser speckle contrast perfusion imaging
    Chizari, Ata
    Knop, Tom
    Sirmacek, Beril
    van Der Heijden, Ferdi
    Steenbergen, Wiendelt
    [J]. BIOMEDICAL OPTICS EXPRESS, 2020, 11 (05): : 2352 - 2365
  • [6] Multi-wavelength, handheld laser speckle imaging for skin evaluation
    Zieger, Michael
    Kaatz, Martin
    Springer, Steffen
    Riesenberg, Rainer
    Wuttig, Andreas
    Kanka, Mario
    Stanca, Sarmiza
    Reble, Carina
    Khazaka, Georg
    Sieg, Robin
    De Gregorio, Marco
    Sattler, Martin
    Fischer, Frank
    [J]. SKIN RESEARCH AND TECHNOLOGY, 2021, 27 (04) : 486 - 493
  • [7] Stabilized diodes enable improved laser speckle contrast imaging
    Chimenti, Robert V.
    [J]. LASER FOCUS WORLD, 2020, 56 (11): : 35 - 37
  • [8] Reliability of handheld laser speckle contrast perfusion imaging demonstrated in psoriasis lesions
    Chizari, Ata
    Schaap, Mirjam J.
    Knop, Tom
    Seyger, Marieke M. B.
    Steenbergen, Wiendelt
    [J]. PHOTONICS IN DERMATOLOGY AND PLASTIC SURGERY 2022, 2022, 11934
  • [9] HANDHELD LASER SPECKLE IMAGING FOR POINT-OF-CARE BLOOD-FLOW MEASUREMENTS
    Lertsakdadet, Ben
    Farraro, Ryan
    Yang, Bruce
    Crouzet, Christian
    Ponticorvo, Adrien
    Durkin, Anthony J.
    Choi, Bernard
    [J]. LASERS IN SURGERY AND MEDICINE, 2017, 49 : 5 - 5
  • [10] Handheld versus mounted laser speckle contrast perfusion imaging demonstrated in psoriasis lesions
    Ata Chizari
    Mirjam J. Schaap
    Tom Knop
    Yoeri E. Boink
    Marieke M. B. Seyger
    Wiendelt Steenbergen
    [J]. Scientific Reports, 11