Indirect evaporative cooling potential in air-water systems in temperate climates

被引:78
|
作者
Costelloe, B [1 ]
Finn, D
机构
[1] Dublin Inst Technol, Dept Bldg Serv Engn, Dublin 8, Ireland
[2] Univ Coll Dublin, Dept Mech Engn, Dublin 2, Ireland
关键词
free cooling; low energy cooling; evaporative cooling; cooling towers; chilled ceilings; chilled ceiling panels; chilled beams;
D O I
10.1016/S0378-7788(02)00161-5
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recent developments have prompted a review of evaporative cooling technology as an effective means of cooling modern deep plan buildings. Prominent among these developments is the success of high temperature sensible cooling systems, particularly, chilled ceilings, which require a supply of cooling water at 14-18 degreesC. Crucial to the success of evaporative cooling technology, as a significant means of cooling in modem applications. is the ability to generate cooling water, in an indirect circuit, at a temperature which closely approaches the ambient adiabatic saturation temperature (AST) or wet bulb temperature (WBT). Recent experimental research has demonstrated that it is technically viable to generate such cooling water at a temperature of 3 K above the ambient AST. While the frequency of ambient AST occurrence can be obtained from meteorological sources, there is little in-depth analysis of the potential for this form of cooling water generation, based on the approach temperatures which have now been shown to be viable. The decision to use an evaporative cooling system depends largely on an assessment, in-depth, of net energy saved against capital expended. Such an assessment requires detailed data on the availability of cooling water, generated by evaporation, for each location. This paper quantifies evaporative cooling availability in-depth for a northern and southern European city, Dublin and Milan and suggests a method of analysing such data for any world wide location, for which suitable meteorological records are available. The paper, incorporates recent experimental research findings and bases the availability analysis on meteorological test reference weather year data. The results of this research confirm a major potential for the generation of cooling water by evaporative means, which can be used to provide effective cooling of deep plan buildings by means of contemporary water based sensible cooling systems, such as fan coil systems, radiant chilled ceiling panels and ceiling cooling convectors (chilled beams). While the technique offers most potential in locations with a northern European temperate climate, it has significant potential to contribute to cooling in some southern European cities, during the non-summer months and also at other times, particularly where load shaving techniques are incorporated. (C) 2002 Elsevier Science B.V All rights reserved.
引用
收藏
页码:573 / 591
页数:19
相关论文
共 50 条
  • [1] Reducing energy consumption of air-conditioning systems in moderate climates by applying indirect evaporative cooling
    Cichon, Aleksandra
    Pacak, Anna
    Pandelidis, Demis
    Anisimov, Sergey
    [J]. 10TH CONFERENCE ON INTERDISCIPLINARY PROBLEMS IN ENVIRONMENTAL PROTECTION AND ENGINEERING EKO-DOK 2018, 2018, 44
  • [2] INDIRECT EVAPORATIVE AIR COOLERS FOR HOT, DRY CLIMATES
    YELLOTT, JI
    GAMERO, J
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1983, 25 (12): : 54 - 54
  • [3] Operational mode optimization of indirect evaporative cooling in hot climates
    Al Horr, Yousef
    Tashtoush, Bourhan
    Chilengwe, Nelson
    Musthafa, Mohamed
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2020, 18
  • [4] A probabilistic analysis of the future potential of evaporative cooling systems in a temperate climate
    Smith, S. Th.
    Hanby, V. I.
    Harpham, C.
    [J]. ENERGY AND BUILDINGS, 2011, 43 (2-3) : 507 - 516
  • [5] Simulation on the evaporative cooling characteristics of humid air-water outside staggered tube bundles
    Tan, Siwen
    Wu, Xuefeng
    Ma, Hongqiang
    Xie, Yue
    Jing, Wei
    Liu, Yemin
    Liu, Min
    Zeng, Yuhang
    Yu, Jinpeng
    Ma, Liangkun
    Chen, Yufei
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2022, 399
  • [6] Modeling of Indirect Evaporative Cooling Systems: A Review
    Caruana, Roberta
    De Antonellis, Stefano
    Marocco, Luca
    Guilizzoni, Manfredo
    [J]. FLUIDS, 2023, 8 (11)
  • [7] INDIRECT-DIRECT EVAPORATIVE COOLING SYSTEMS
    ESKRA, N
    [J]. ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1980, 22 (05): : 21 - 25
  • [8] Potential of indirect evaporative cooling to reduce the energy consumption in fresh air conditioning applications
    Porumb, Bogdan
    Balan, Mugur
    Porumb, Raluca
    [J]. EENVIRO-YRC 2015 - BUCHAREST, 2016, 85 : 433 - 441
  • [9] Comparison of Two Kinds of Indirect Evaporative Cooling System: To Produce Cold Water and To Produce Cooling Air
    Xie, Xiaoyun
    Jiang, Yi
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 881 - 890
  • [10] Performance evaluation of an indirect air cooling system combined with evaporative cooling
    Sibanda, Sipho
    Workneh, Tilahun Seyoum
    [J]. HELIYON, 2020, 6 (01)