Determination of Elemental Composition in Soft Biological Tissue Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry: Method Validation

被引:2
|
作者
LaBine, Geriene O. [1 ]
Molloy, Philip P. [1 ]
Christensen, Jennie R. [1 ]
机构
[1] TrichAnalytics Inc, 207-1753 Sean Hts, Saanichton, BC V8M 0B3, Canada
关键词
Elemental analysis; environmental monitoring; fish; green chemistry; laser ablation inductively coupled mass spectrometry; LA-ICP-MS; metals; method validation; LA-ICP-MS; ENVIRONMENTAL-SAMPLES; FISH; SPECIATION; MERCURY; METALS; GULF;
D O I
10.1177/00037028211008535
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Determination of elemental concentrations in biological tissue is fundamental to many environmental studies. Analytical methods typically used to quantify concentrations in such studies have minimum sample volumes that necessitate lethal or impactful collection of tissues. Laser ablation inductively coupled mass spectrometry (LA-ICP-MS) has small sample volume requirements and offers environmental practitioners an opportunity to employ low-impact sample collection methods. Environmental applications of LA-ICP-MS are limited by the lack of validated methods, partly due to the need for dry samples and scarcity of matrix-matched certified reference materials (CRMs). This study validates an LA-ICP-MS method to determine concentrations of 30 elements in soft biological tissue (fish ovary and muscle). Tissue samples (median: 0.48 grams (g); inter-quartile range: 0.30 g to 0.56 g wet weight) were dehydrated, powdered, compressed into pellets (weighing approximately 0.03 g) and analyzed using LA-ICP-MS alongside three matrix-matched CRMs. The method yielded concentration determinations for CRM elements that were typically accurate to within 30% of theoretical concentrations, and precise (relative standard deviation <20%). These results were repeatable: accuracy rarely deviated from theoretical values by more than 20%, and precision rarely exceeded 33%. Determinations for biological samples were replicable irrespective of tissue (ovary or muscle). There was good linearity between analyte signal strength and theoretical concentration (median R-2 >= 0.981 for all elements) across ranges typically encountered in environmental studies. Concentrations could not be consistently obtained (i.e., determined concentrations were typically below detection limits) for boron, vanadium, molybdenum, and cadmium in muscles, and arsenic in both ovaries and muscles; however, detection limits were sufficiently low for most environmental contexts. Further methodological refinement could include the incorporation of spiked standards to extend linear ranges, and fine-tuning instrument parameters to obtain smoother signal intensities for rare elements. The method presented promotes the use of low-impact sample collection methods while enabling high-quality determinations of elemental concentrations in biological tissues.
引用
收藏
页码:1262 / 1277
页数:16
相关论文
共 50 条
  • [1] Elemental Fractionation Studies of Biological Samples Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Li Qing
    Zhang Guo-Xia
    Chen Yi-Rui
    Wang Zheng
    Ding Chuan-Xian
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (06) : 868 - 873
  • [2] Elemental fractionation in laser ablation inductively coupled plasma mass spectrometry
    Longerich, HP
    Gunther, D
    Jackson, SE
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 355 (5-6): : 538 - 542
  • [3] Elemental fractionation of glass using laser ablation inductively coupled plasma mass spectrometry
    Figg, D
    Kahr, MS
    APPLIED SPECTROSCOPY, 1997, 51 (08) : 1185 - 1192
  • [4] Calibration for Elemental Dental Tissue Analysis by Laser Ablation Inductively Coupled Plasma Mass Spectrometry
    Miliszkiewicz, N.
    Walas, S.
    Tobiasz, A.
    Kolodziej, M.
    Szostek, K.
    ANALYTICAL LETTERS, 2017, 50 (08) : 1345 - 1359
  • [6] Elemental analysis of Spanish moss using laser ablation inductively coupled plasma mass spectrometry
    Bi, M
    Austin, E
    Smith, BW
    Winefordner, JD
    ANALYTICA CHIMICA ACTA, 2001, 435 (02) : 309 - 318
  • [7] Soft ablation technique for laser ablation-inductively coupled plasma mass spectrometry
    Tokyo Inst of Technology, Tokyo, Japan
    J Anal At Spectrom, 11 (1337-1342):
  • [8] Imaging mass spectrometry in biological tissues by laser ablation inductively coupled plasma mass spectrometry
    Becker, J. S.
    Su, J.
    Zoriya, M. V.
    Dobrowolska, J.
    Matusch, A.
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2007, 13 (01) : 1 - 6
  • [9] Elemental Analysis of Solid Food Materials Using a Reliable Laser Ablation Inductively Coupled Plasma Mass Spectrometry Method
    Zhou, Jianzong
    Guo, Wei
    Jin, Lanlan
    Hu, Shenghong
    Journal of Agricultural and Food Chemistry, 2022, 70 (15): : 4765 - 4773
  • [10] Direct elemental analysis of food by laser ablation inductively coupled plasma mass spectrometry
    Todorov, Todor
    Jo, Guyhan
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254