Centrifuge modelling of the pushover failure of an electricity transmission tower

被引:7
|
作者
Richards, D. J. [1 ]
White, D. J. [2 ]
Lehane, B. M. [3 ]
机构
[1] Univ Southampton, Sch Civil Engn & Environm, Southampton SO17 1BJ, Hants, England
[2] Univ Western Australia, Fac Engn Comp & Math, Ctr Offshore Fdn Syst, Crawley, WA 6009, Australia
[3] Univ Western Australia, Sch Civil Engn & Resource Engn, Crawley, WA 6009, Australia
关键词
transmission towers; shallow footings; rate effects; uplift; ANCHOR PLATES; UPLIFT CAPACITY; CLAY; BEHAVIOR; SAND; FOOTINGS; SOIL;
D O I
10.1139/T09-112
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Centrifuge model tests were conducted to examine foundation failure mechanisms during rapid horizontal pushover of an electricity transmission line support tower, simulating a broken transmission line response or wind gust loading. A model transmission tower supported on four pad foundations in clay and backfilled with sand was loaded horizontally and the loads at each foundation were measured during fast and slow pushover. The tests examined the influence of tensile resistance mobilized at the underside of the footings, which is difficult to reliably incorporate within design practice due to a lack of accepted quantitative design methods. The measured performance of the tower footings was compared with results from a series of tests where a single footing is subjected to purely vertical loading in compression and tension and was found to be in good agreement. The tower response was back-analysed as a simple push-pull model and the calculated uplift capacity of the footing backfill provided a close match to the observed response of the tower footings subjected to slow pushover. During fast pushover, the additional capacity mobilized due to tensile resistance (suction) created by the reverse bearing capacity beneath the base of the footings subjected to uplift was quantified using a suction capacity factor.
引用
收藏
页码:413 / 424
页数:12
相关论文
共 50 条
  • [1] Analysis of transmission tower structure with Pushover Method
    Qin, Kang
    Xun, Zhonggen
    Deng, Changgen
    ADVANCES IN CIVIL STRUCTURES, PTS 1 AND 2, 2013, 351-352 : 203 - 207
  • [2] Failure evaluation of transmission tower with asymmetrical legs by Scaled-Down pushover experiment
    Saddek, Ahmed Abdalfatah
    Lin, Tzu-Kang
    Sawadogo, Alain
    ENGINEERING STRUCTURES, 2023, 279
  • [3] Modelling of tornado and microburst-induced wind loading and failure of a lattice transmission tower
    Savory, E
    Parke, GAR
    Zeinoddini, M
    Toy, N
    Disney, P
    ENGINEERING STRUCTURES, 2001, 23 (04) : 365 - 375
  • [4] Centrifuge study on the uplift behavior of spread foundation for transmission tower in sand
    Gu, Kyo-Young
    Tran, Nghiem Xuan
    Han, Jayne M.
    Kim, Kyeong-Sun
    Ham, Kyung-Won
    Kim, Sung-Ryul
    CANADIAN GEOTECHNICAL JOURNAL, 2024, 61 (07) : 1418 - 1432
  • [5] Typhoon-induced failure analysis of electricity transmission tower-line system incorporating microtopography
    Meng, Xiangrui
    Tian, Li
    Ma, Ruisheng
    Zhang, Laiyi
    Liu, Juncai
    Dong, Xu
    ENGINEERING FAILURE ANALYSIS, 2024, 163
  • [6] High accuracy measurement of deflections of an electricity transmission line tower
    Moschas, Fanis
    Stiros, Stathis
    ENGINEERING STRUCTURES, 2014, 80 : 418 - 425
  • [7] Failure analysis of risk load on transmission tower
    Liu, Minshan
    Sun, Mingying
    Dong, Qiwu
    Liu, Tong
    Zhang, Lina
    EVALUATION, INSPECTION AND MONITORING OF STRUCTURAL INTEGRITY, 2008, : 347 - 350
  • [8] A simple failure analysis of the composite transmission tower
    Yeh, HY
    Yeh, HL
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 2001, 20 (12) : 1054 - 1065
  • [9] Failure analysis of a transmission tower during a microburst
    Shehata, A. Y.
    El Damatty, A. A.
    WIND AND STRUCTURES, 2008, 11 (03) : 193 - 208
  • [10] Modelling of a transmission tower for lightning-surge analysis
    Hara, T
    Yamamoto, O
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (03) : 283 - 289