Reliability and validity of the Myotest® for measuring running stride kinematics

被引:30
|
作者
Gindre, Cyrille [1 ]
Lussiana, Thibault [1 ,2 ,3 ]
Hebert-Losier, Kim [4 ]
Morin, Jean-Benoit [5 ]
机构
[1] Volodalen Compagny, Dept Res & Dev, Chaveria, France
[2] Univ Franche Comte, Res Unit EA4660, Culture Sport Hlth Soc, F-25030 Besancon, France
[3] Univ Franche Comte, Exercise Performance Hlth Innovat Platform, F-25030 Besancon, France
[4] Natl Sports Inst Malaysia, Kompleks Sukan Negara,Peti Surat 7102, Kuala Lumpur, Malaysia
[5] Univ Lyon, Res Unit EA4338, Exercise Physiol Lab, CHU Bellevue Med Sport & Myol, St Etienne, France
关键词
Running; biomechanics; technology; concurrent validity; reliability; VERTICAL JUMP PERFORMANCE; SPORTS-MEDICINE; EXERCISE; SPEED; SQUAT; POWER; REPRODUCIBILITY; SPRINTERS; SCIENCE; SYSTEMS;
D O I
10.1080/02640414.2015.1068436
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Accelerometer-based systems are often used to quantify human movement. This study's aim was to assess the reliability and validity of the Myotest (R) accelerometer-based system for measuring running stride kinematics. Twenty habitual runners ran two 60 m trials at 12, 15, 18 and 21 km.h(-1). Contact time, aerial time and step frequency parameters from six consecutive running steps of each trial were extracted using Myotest (R) data. Between-trial reproducibility of measures was determined by comparing kinematic parameters from the two runs performed at the same speed. Myotest (R) measures were compared against photocell-based (Optojump Next (R)) and high-frequency video data to establish concurrent validity. The Myotest (R)-derived parameters were highly reproducible between trials at all running speeds (intra-class correlation coefficient (ICC): 0.886 to 0.974). Compared to the photo-cell and high-speed video-based measures, the mean contact times from the Myotest (R) were 34% shorter and aerial times were 64% longer. Only step frequency was comparable between systems and demonstrated high between-system correlation (ICC >= 0.857). The Myotest (R) is a practical portable device that is reliable for measuring contact time, aerial time and step frequency during running. In terms of validity, it provides accurate step frequency measures but underestimates contact time and overestimates aerial time compared to photocell-and optical-based systems.
引用
收藏
页码:664 / 670
页数:7
相关论文
共 50 条
  • [1] ABSOLUTE RELIABILITY AND CONCURRENT VALIDITY OF THE STRYD SYSTEM FOR THE ASSESSMENT OF RUNNING STRIDE KINEMATICS AT DIFFERENT VELOCITIES
    Garcia-Pinillos, Felipe
    Roche-Seruendo, Luis E.
    Marcen-Cinca, Noel
    Marco-Contreras, Luis A.
    Latorre-Roman, Pedro A.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2021, 35 (01) : 78 - 84
  • [2] The Validity and Reliability of an iPhone App for Measuring Running Mechanics
    Balsalobre-Fernandez, Carlos
    Agopyan, Hovannes
    Morin, Jean-Benoit
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (03) : 222 - 226
  • [3] Myotest efficiency in the mechanical analysis of the stride
    Deflandre, Dorian
    Miny, Kevin
    Schwartz, Cedric
    Dardenne, Nadia
    Leclerc, Anne-France
    Bury, Thierry
    [J]. GAZZETTA MEDICA ITALIANA ARCHIVIO PER LE SCIENZE MEDICHE, 2018, 177 (06) : 293 - 300
  • [4] Validity and reliability of the Myotest Pro wireless accelerometer in squat jumps
    Bampouras, Theodoros M.
    Relph, Nicola S.
    Orme, Duncan
    Esformes, Joseph I.
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2013, 21 (02) : 101 - 105
  • [5] Validity and Reliability of a Commercial Fitness Watch for Measuring Running Dynamics
    Adams, Douglas
    Pozzi, Federico
    Carroll, Anthony
    Rombach, Andrew
    Zeni, Joseph, Jr.
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2016, 46 (06): : 471 - 476
  • [6] VALIDITY OF THE MYOTEST® IN MEASURING FORCE AND POWER PRODUCTION IN THE SQUAT AND BENCH Press
    Comstock, Brett A.
    Solomon-Hill, Glenn
    Flanagan, Shawn D.
    Earp, Jacob E.
    Luk, Hui-Ying
    Dobbins, Kathryn A.
    Dunn-Lewis, Courtenay
    Fragala, Maren S.
    Ho, Jen-Yu
    Hatfield, Disa L.
    Vingren, Jakob L.
    Denegar, Craig R.
    Volek, Jeff S.
    Kupchak, Brian R.
    Maresh, Carl M.
    Kraemer, William J.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2011, 25 (08) : 2293 - 2297
  • [7] Validity And Reliability Of The Myotest® Height Displacement Among Hiv plus Hispanics
    Lopez-Roman, Luis R.
    Ramirez-Marrero, Farah A.
    Bonilla, Victor
    Rosario-Canales, Martin
    Cernuda, Jose V.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 692 - 692
  • [8] VALIDITY AND RELIABILITY OF THE MYOTEST ACCELEROMETRIC SYSTEM FOR THE ASSESSMENT OF VERTICAL JUMP HEIGHT
    Casartelli, Nicola
    Mueller, Roland
    Maffiuletti, Nicola A.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2010, 24 (11) : 3186 - 3193
  • [9] Reliability and concurrent criterion validity of a novel technique for analyzing hip kinematics during running
    Atkins, Lee T.
    James, C. Roger
    Sizer, Phillip S.
    Jonely, H.
    Brismee, Jean-Michel
    [J]. PHYSIOTHERAPY THEORY AND PRACTICE, 2014, 30 (03) : 210 - 217
  • [10] Running Stride Kinematics And Trunk Accelerations Are Affected By Body Mass Index
    Jording, Lauren
    Lindsay, Timothy R.
    McGregor, Stephen J.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 950 - 950