Evaluation on energy performance in a low-energy building using new energy conservation index based on monitoring measurement system with sensor network

被引:15
|
作者
Wang, Yang [1 ,2 ]
Kuckelkorn, Jens M. [1 ]
Zhao, Fu-Yun [3 ]
Mu, Mulan [4 ]
Li, Daoliang [5 ]
机构
[1] Bavarian Ctr Appl Energy Res ZAE Bayern, Div Technol Energy Syst & Renewable Energy, D-85748 Garching, Germany
[2] Coventry Univ, Sch Energy Construct & Environm, Fac Engn Environm & Comp, Coventry CV1 2HF, W Midlands, England
[3] Wuhan Univ, Sch Power & Mech Engn, Wuhan 430072, Hubei Province, Peoples R China
[4] Univ Warwick, WMG, Int Inst Nanocomposites Mfg, Coventry CV4 7AL, W Midlands, England
[5] China Agr Univ, Coll Informat & Elect Engn, Beijing 100083, Peoples R China
关键词
Building energy performance; Energy conservation ratio; Heat recovery ventilation; Heat recovery efficiency; Monitoring measurements; Sensor network; CLASSROOM AIR ENVIRONMENT; LOW-CARBON; HEAT; CONSUMPTION; EFFICIENCY; DEMAND; SIMULATIONS; BENCHMARKS; GAINS;
D O I
10.1016/j.enbuild.2016.04.056
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Improving building energy efficiency and decreasing building energy consumption through monitoring of-heating, ventilation and air conditioning (HVAC) and heat recovery systems are becoming increasingly significant due to global energy crisis and carbon emission. Therefore, evaluation on building energy efficiency and energy conservation is extremely necessary. In the present work, energy conservation performance of one low-energy school building will be intensively investigated based on more than three-year measurement results from the monitoring system with sensor network. Heat recovery efficiency and new energy conservation parameter were analytically modeled, taking the building mechanical ventilation network into account. Following that, building energy performance has been experimentally investigated concerning the effects of mechanical ventilation rates, outdoor temperature and the efficiency of the heat recovery facility. Subsequent energy performance analysis demonstrates that building energy demands for ventilation and winter heating could be decreased with the enhancement of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air conditioning unit increases with the temperature of supply fresh air. Diverse situations of energy conservation ratio and heat recovery efficiency have been detailedly correlated according to measurement results. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:79 / 91
页数:13
相关论文
共 50 条
  • [1] Energy performance evaluation of a low-energy academic building
    Pless, Shanti D.
    Torcellini, Paul A.
    Petersen, John E.
    [J]. ASHRAE TRANSACTIONS 2006, VOL 112, PT 1, 2006, 112 : 295 - +
  • [2] Evaluation on distributed renewable energy system integrated with a Passive House building using a new energy performance index
    Wang, Yang
    Kuckelkorn, Jens
    Li, Daoliang
    Du, Jiangtao
    [J]. ENERGY, 2018, 161 : 81 - 89
  • [3] Research of Building Energy Conservation Index System and Comprehensive Evaluation Method
    Liu, A. F.
    Guo, S. H. R.
    [J]. CRIOCM2009: INTERNATIONAL SYMPOSIUM ON ADVANCEMENT OF CONSTRUCTION MANAGEMENT AND REAL ESTATE, VOLS 1-6, 2009, : 1584 - 1592
  • [4] Building performance evaluation of low-energy dwellings with and without smart thermostats
    Gupta, Rajat
    Gregg, Matt
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2022, 43 (03): : 297 - 318
  • [5] MONITORING THE PERFORMANCE OF ENERGY-DISPERSIVE SPECTROMETER DETECTORS AT LOW-ENERGY
    HOVINGTON, P
    LESPERANCE, G
    BARIL, E
    RIGAUD, M
    [J]. SCANNING, 1995, 17 (03) : 136 - 139
  • [6] Home Energy Monitoring System using Wireless Sensor Network
    Shafique, Muhammad Tayyab
    Kamran, Hassan
    Arshad, Hafsa
    Khattak, Hasan Ali
    [J]. 2018 14TH INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES (ICET), 2018,
  • [7] Sensor Network System to Promote Energy Conservation Realization of Energy Smart School
    Kuzume, Koichi
    Okada, Masakazu
    [J]. 2014 IEEE INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING AND COMMUNICATIONS WORKSHOPS (PERCOM WORKSHOPS), 2014, : 187 - 190
  • [8] Energy performance evaluation of thermo-active building system based on simulation and measurement
    Muramatsu, Hiroshi
    Togashi, Eisuke
    Nobe, Tatsuo
    [J]. Journal of Environmental Engineering (Japan), 2019, 84 (762): : 759 - 769
  • [9] Performance of a low-energy commercial building designed using a whole-building approach
    Torcellini, PA
    Hayter, SJ
    Ketcham, MS
    Judkoff, R
    [J]. PROCEEDINGS OF THE 23RD NATIONAL PASSIVE SOLAR CONFERENCE, 1998, 23 : 33 - 38
  • [10] Prediction of Low-Energy Building Energy Consumption Based on Genetic BP Algorithm
    Lu, Yanhua
    Gong, Xuehui
    Kipnis, Andrew Byron
    [J]. CMC-COMPUTERS MATERIALS & CONTINUA, 2022, 72 (03): : 5481 - 5497