A modified thrombin generation test for the measurement of factor VIII concentrates

被引:33
|
作者
Mcintosh, JH
Owens, D
Lee, CA
Raut, S
Barrowcliffe, TW
机构
[1] Natl Inst Biol Stand & Controls, Div Haematol, Potters Bar EN6 3QG, Herts, England
[2] Royal Free Hosp, Haemophilia Ctr, London NW3 2QG, England
[3] Royal Free Hosp, Haemostasis Unit, London NW3 2QG, England
关键词
factor VIII concentrates; hemophilia A; thrombin generation;
D O I
10.1046/j.1538-7836.2003.00209.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
It has been well documented that there is an uncertainty over the true factor (F)VIII level in postinfusion samples due to assay discrepancies. The thrombin generation test (TGT) was used as a potentially more physiological approach to assess and compare FVIII concentrates. FVIII concentrates were added to artificial FVIII-deficient plasma. Thrombin generation was initiated by the addition of FIXa (14 nM), phospholipid and CaCl2. Thrombin was measured by subsampling into fibrinogen, and curves quantified as area under the curve (AUC) and time taken to half-maximum (t(1/2max)). Addition of one plasma-derived concentrate to as little as 0.005 IU mL(-1) gave a normal AUC, but prolonged t(1/2max). Increasing FVIII to 1 IU mL(-1) had little effect on AUC, but did reduce the t(1/2max) to 64s (normal 114s). A range of plasma-derived and recombinant concentrates were tested at 1 Iu ML-1; results were similar, except the B-domain deleted concentrate, which had the most rapid initial rate of thrombin generation (t(1/2max) 48s, P < 0.05). Two hemophilic plasmas (< 0.01 IU mL(-1)) produced large amounts of thrombin (AUC 65% and 69%), although t(1/2max) was prolonged. Addition of a FVIII antibody abolished thrombin generation, indicating that these plasmas contained low levels of FVIII. Decreasing the FIXa concentration (0.2 nM) minimized thrombin generation in hemophilic plasma but not in normal plasma. These results indicate that FVIII < 0.01 IU mL(-1) can generate significant quantities of thrombin depending upon the amount of FIXa present. The TGT could prove useful for patient monitoring in gene therapy and prophylaxis.
引用
收藏
页码:1005 / 1011
页数:7
相关论文
共 50 条
  • [1] Optimization of the thrombin generation test components to measure potency of factor VIII concentrates
    Jha, N. K.
    Shestopal, S. A.
    Gourley, M. J.
    Woodle, S. A.
    Liang, Y.
    Sarafanov, A. G.
    Weinstein, M.
    Ovanesov, M. V.
    HAEMOPHILIA, 2016, 22 (05) : 780 - 789
  • [2] Development of a Continuous Thrombin Generation-Based Test to Measure Potency in Factor VIII Concentrates
    Gourley, Merek J.
    Shestopal, Svetlana A.
    Lee, Timothy K.
    Ovanesov, Mikhail V.
    BLOOD, 2011, 118 (21) : 542 - 543
  • [3] Impact of different inhibitor reactivities with commercial factor VIII concentrates on thrombin generation
    Salvagno, G. L.
    Astermark, J.
    Ekman, M.
    Franchini, M.
    Midi, G. C.
    Lippi, G.
    Poli, G.
    Berntorp, E.
    HAEMOPHILIA, 2007, 13 (01) : 51 - 56
  • [4] Impact on thrombin generation of different factor VIII concentrates in patients with acquired haemophilia
    Salvagno, G.
    Astermark, J.
    Gunnarsson, M.
    Franchini, M.
    Poli, G.
    Guidi, G.
    Lippi, G.
    Berntorp, E.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 502 - 502
  • [5] A modified thrombin generation test for investigating very low levels of factor VIII activity in hemophilia A
    Tomoko Matsumoto
    Keiji Nogami
    Kenichi Ogiwara
    Midori Shima
    International Journal of Hematology, 2009, 90 : 576 - 582
  • [6] A modified thrombin generation test for investigating very low levels of factor VIII activity in hemophilia A
    Matsumoto, Tomoko
    Nogami, Keiji
    Ogiwara, Kenichi
    Shima, Midori
    INTERNATIONAL JOURNAL OF HEMATOLOGY, 2009, 90 (05) : 576 - 582
  • [7] Thrombin generation and hemophilia: inhibitor reactivity employing different commercial factor VIII concentrates.
    Salvagno, G. L.
    Astermark, J.
    Lippi, G.
    Guidi, G. C.
    Franchini, M.
    Poli, G.
    Montagnana, M.
    Ekman, M.
    Berntorp, E.
    CLINICAL CHEMISTRY, 2006, 52 (06) : A29 - A29
  • [8] A pharmacokinetic study: impact on thrombin generation of two recombinant factor VIII concentrates in subjects with haemophilia A
    Salvagno, G.
    Astermark, J.
    Ekman, M.
    Franchini, M.
    Guidi, G.
    Lippi, G.
    Janco, R.
    Berntorp, E.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 502 - 503
  • [9] Potency measurement of factor VIII in recombinant concentrates
    Farrugia, A
    Rochfort, P
    Fry, KJ
    Tran, E
    Poulis, M
    HAEMOPHILIA, 1996, 2 (03) : 153 - 159
  • [10] Thrombin generation test optimized to measure treatment of factor VIII deficiency with recombinant factor VIIa
    Giesen, P. L. A.
    van Oerle, R.
    Spronk, H. M. H.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 223 - 223