Transfer of spectral data between Fourier-transform infrared spectrometers for use in discriminant analysis of fruit purees

被引:0
|
作者
Holland, JK
Kemsley, EK
Wilson, RH
机构
[1] Institute of Food Research, Norwich Laboratory, Colney, Norwich, NR4 7UA, Norwich Research Park
关键词
infrared; spectroscopy; spectrum transfer; discriminant analysis; principal components; fruit purees;
D O I
10.1002/(SICI)1097-0010(199711)75:3<391::AID-JSFA894>3.0.CO;2-7
中图分类号
S [农业科学];
学科分类号
09 ;
摘要
The mid-infrared spectra of raspberry and strawberry purees were acquired on two Fourier-transform spectrometers. A pre-treatment procedure, involving baseline correction and area normalisation, was developed that made the spectra from the two spectrometers compatible for use in discriminant analyses. The discriminant analyses were performed by subjecting the spectra to a principal component (PC) analysis, grouping them according to fruit species and then assigning samples to the class with the closest group mean in PC space. Models using the first PC scores of the pre-treated spectra from one spectrometer were able to correctly assign the fruit species of between 91.1 and 96.4% of the pre-treated spectra of independent test sets of the other. However, the projection of the spectra from each spectrometer into the same PC space showed differences in the mean positions of equivalent groups along the second and higher PCs. Therefore, the transfer of this data set is only wholly reliable using the first PC scores. Tests with the uncorrected spectra demonstrated their incompatibility through the complete lack of overlap of equivalent fruit species groups in PC space.
引用
收藏
页码:391 / 400
页数:10
相关论文
共 50 条
  • [1] Transferability of a large mid-infrared soil spectral library between two Fourier-transform infrared spectrometers
    Sanderman, Jonathan
    Gholizadeh, Asa
    Pittaki-Chrysodonta, Zampela
    Huang, Jingyi
    Safanelli, Jose Lucas
    Ferguson, Richard
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2023, 87 (03) : 586 - 599
  • [2] Detecting aerosols and vapors with Fourier-Transform InfraRed spectrometers
    Ben-David, Avishai
    D'Amico, Francis M.
    2005 IEEE Aerospace Conference, Vols 1-4, 2005, : 2012 - 2021
  • [3] RESOLUTION AND INSTRUMENT LINE-SHAPE EFFECTS ON SPECTRAL COMPENSATION WITH FOURIER-TRANSFORM INFRARED SPECTROMETERS
    ANDERSON, RJ
    GRIFFITHS, PR
    ANALYTICAL CHEMISTRY, 1978, 50 (13) : 1804 - 1811
  • [4] A procedure for testing the radiometric accuracy of fourier-transform infrared spectrometers
    Zhang, ZM
    Hanssen, LM
    Hsia, JJ
    Datla, RU
    Zhu, CJ
    Griffiths, PR
    MIKROCHIMICA ACTA, 1997, : 315 - 316
  • [5] Fourier-Transform Infrared Spectral Library of MXenes
    Parker, Tetiana
    Zhang, Danzhen
    Bugallo, David
    Shevchuk, Kateryna
    Downes, Marley
    Valurouthu, Geetha
    Inman, Alex
    Chacon, Benjamin
    Zhang, Teng
    Shuck, Christopher E.
    Hu, Yong-Jie
    Gogotsi, Yury
    CHEMISTRY OF MATERIALS, 2024, 36 (17) : 8437 - 8446
  • [6] Analysis and design of compact, static Fourier-transform spectrometers
    Montarou, CC
    Gaylord, TK
    APPLIED OPTICS, 2000, 39 (31) : 5762 - 5767
  • [7] FOURIER-TRANSFORM METHODS FOR ANALYSIS OF GE(LI) SPECTRAL DATA
    CHAMBLESS, DA
    BROADWAY, JA
    HEALTH PHYSICS, 1977, 33 (06): : 663 - 663
  • [8] SAMPLING JITTER IN FOURIER-TRANSFORM SPECTROMETERS - SPECTRAL BROADENING AND NOISE EFFECTS
    MEYNART, R
    APPLIED OPTICS, 1992, 31 (30): : 6383 - 6388
  • [9] THE USE OF FOURIER-TRANSFORM INFRARED-SPECTROSCOPY IN THE ANALYSIS OF FOODSTUFFS
    BELTON, P
    AGRICULTURE, FOOD CHEMISTRY AND THE CONSUMER, VOLS 1 AND 2: THE CONSUMER AND FOOD, ANALYTICAL FOOD CHEMISTRY AND AGRICULTURAL PRODUCTION, BIOTECHNOLOGY AND BIOASSAYS - IMPACT OF TECHNOLOGY ON FOOD QUALITY, FOOD CHEMISTRY AND QUALITY ASSURANCE, 1989, : 587 - 591
  • [10] POSTDISPERSION SYSTEM FOR ASTRONOMICAL OBSERVATIONS WITH FOURIER-TRANSFORM SPECTROMETERS IN THE THERMAL INFRARED
    WIEDEMANN, G
    JENNINGS, DE
    HANEL, RH
    KUNDE, VG
    MOSELEY, SH
    LAMB, G
    PETROFF, MD
    STAPELBROEK, MG
    APPLIED OPTICS, 1989, 28 (01): : 139 - 145