Effective dose equivalent and effective dose: Comparison for common projections in oral and maxillofacial radiology

被引:43
|
作者
Gibbs, SJ [1 ]
机构
[1] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
关键词
D O I
10.1067/moe.2000.109189
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. Effective dose equivalents (H-E) and effective doses (E) for radiographic projections common in dentistry, calculated from the same organ dose distributions, are presented to determine whether the 2 quantities can be directly compared. Study design. Doses to all organs and tissues in the head, neck, trunk. and proximal extremities were determined for each projection (intraoral full-mouth radiographic survey, panoramic, cephalometric, temporomandibular tomograms, and submentovertex view) by computer simulation with Monte Carlo methods. H-E and E were calculated from these complete distributions and by methods prescribed by the International Commission on Radiological Protection (ICRP). Results. H-E and E computed from complete dose distributions were found comparable within a few percentage points. However, those computed by strict application of ICRP methods were not. Conclusion. For radiographic projections with highly localized dose distributions, such as those common in dentistry, direct comparison of H-E and E may not be meaningful, unless both computation algorithms are known.
引用
收藏
页码:538 / 545
页数:8
相关论文
共 50 条
  • [1] THE EFFECTIVE DOSE EQUIVALENT IN RADIOLOGY
    HUDA, W
    LENTLE, B
    SUTHERLAND, JB
    [J]. JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1989, 40 (01): : 3 - 4
  • [2] Comparison of personal dose equivalent and effective dose
    Clark, MJ
    Chartier, JL
    Siebert, BRL
    Zankl, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 78 (02) : 91 - 99
  • [3] COMPARISON OF THE BIOLOGICALLY EFFECTIVE UNIFORM DOSE, EQUIVALENT UNIFORM DOSE, EFFECTIVE DOSE AND GENERALIZED EQUIVALENT UNIFORM DOSE CONCEPTS
    Mavroidis, P.
    Papanikolaou, N.
    Lind, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S239 - S240
  • [4] MEASUREMENT OF EFFECTIVE DOSE EQUIVALENT IN DIAGNOSTIC-RADIOLOGY
    FAULKNER, K
    HARRISON, RM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 792 - 793
  • [5] Effective dose and effective dose equivalent in nuclear medicine
    Toohey, RE
    Stabin, MG
    [J]. IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C473 - C475
  • [6] EFFECTIVE DOSE EQUIVALENT
    SHIELDS, RA
    LAWSON, RS
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 1987, 8 (11) : 851 - 855
  • [7] ESTIMATION OF EFFECTIVE DOSE EQUIVALENT TO STAFF IN DIAGNOSTIC-RADIOLOGY
    FAULKNER, K
    HARRISON, RM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (01): : 83 - 91
  • [8] Effective dose equivalent estimates in diagnostic radiology with single dosimetry
    Michel, R
    Perle, SC
    [J]. HEALTH PHYSICS, 2000, 79 (02): : S17 - S19
  • [9] The effective dose equivalent and effective dose for hot particles on the skin
    Xu, XG
    [J]. HEALTH PHYSICS, 2005, 89 (01): : 53 - 70
  • [10] ON INCLUSION OF THE DOSE TO SKIN IN THE EFFECTIVE DOSE EQUIVALENT
    KOCHER, DC
    ECKERMAN, KF
    [J]. HEALTH PHYSICS, 1988, 55 (05): : 813 - 815