A general model for estimating lower extremity inertial properties of individuals with transtibial amputation

被引:13
|
作者
Ferris, Abbie E. [1 ]
Smith, Jeremy D. [1 ]
Heise, Gary D. [1 ]
Hinrichs, Richard N. [2 ]
Martin, Philip E. [3 ]
机构
[1] Univ Northern Colorado, Sch Sport & Exercise Sci, Campus Box 39,Gunter 2680, Greeley, CO 80639 USA
[2] Arizona State Univ, Dept Kinesiol, Phoenix, AZ USA
[3] Iowa State Univ, Dept Kinesiol, Ames, IA USA
关键词
Amputee; Gait; Biomechanics; Inertial properties; JOINT MOMENTS; INVERSE DYNAMICS; PROSTHETIC MASS; WALKING; KINETICS; GAIT; UNCERTAINTIES;
D O I
10.1016/j.jbiomech.2017.01.034
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Lower extremity joint moment magnitudes during swing are dependent on the inertial properties of the prosthesis and residual limb of individuals with transtibial amputation (TTA). Often, intact limb inertial properties (INTACT) are used for prosthetic limb values in an inverse dynamics model even though these values overestimate the amputated limb's inertial properties. The purpose of this study was to use subject-specific (SPECIFIC) measures of prosthesis inertial properties to generate a general model (GENERAL) for estimating TTA prosthesis inertial properties. Subject-specific mass, center of mass, and moment of inertia were determined for the shank and foot segments of the prosthesis (n = 11) using an oscillation technique and reaction board. The GENERAL model was derived from the means of the SPECIFIC model. Mass and segment lengths are required GENERAL model inputs. Comparisons of segment inertial properties and joint moments during walking were made using three inertial models (unique sample; n = 9): (1) SPECIFIC, (2) GENERAL, and (3) INTACT. Prosthetic shank inertial properties were significantly smaller with the SPECIFIC and GENERAL model than the INTACT model, but the SPECIFIC and GENERAL model did not statistically differ. Peak knee and hip joint moments during swing were significantly smaller for the SPECIFIC and GENERAL model compared with the INTACT model and were not significantly different between SPECIFIC and GENERAL models. When subject-specific measures are unavailable, using the GENERAL model produces a better estimate of prosthetic side inertial properties resulting in more accurate joint moment measurements for individuals with TTA than the INTACT model. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:44 / 48
页数:5
相关论文
共 50 条
  • [1] Running footstrike pattern effect on lower extremity work in an individual with transtibial amputation
    Djafar, Tatiana E.
    Stewart, Julianne M.
    Collins, John D.
    Kingsbury, Trevor D.
    [J]. PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2022, 46 (06) : 549 - 552
  • [2] Lower-extremity inter-joint coordination variability in active individuals with transtibial amputation and healthy males during gait
    Nasri, Alireza
    Abbasi, Ali
    Hadavi, Zeynab
    Abbasi, Shahram
    Svoboda, Zdenek
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01):
  • [3] Lower Extremity Joint Contributions to Trunk Control During Walking in Persons with Transtibial Amputation
    Adam J. Yoder
    Amy Silder
    Shawn Farrokhi
    Christopher L. Dearth
    Brad D. Hendershot
    [J]. Scientific Reports, 9
  • [4] Rare Lower Extremity Fibrosarcomatous Variant of Dermatofibrosarcoma With Myxoid Features Treated With Transtibial Amputation
    Pryor, Elizabeth K.
    Sinkler, Margaret A.
    Ullah, Asad
    Martin, Elizabeth
    Homlar, Kelly
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (09)
  • [5] Lower Extremity Joint Contributions to Trunk Control During Walking in Persons with Transtibial Amputation
    Yoder, Adam J.
    Silder, Amy B.
    Farrokhi, Shawn
    Dearth, Christopher L.
    Hendershot, Brad D.
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [6] Suicidal Ideation Among Individuals With Dysvascular Lower Extremity Amputation
    Turner, Aaron P.
    Meites, Tiffany M.
    Williams, Rhonda M.
    Henderson, Alison W.
    Norvell, Daniel C.
    Hakimi, Kevin N.
    Czerniecki, Joseph M.
    [J]. ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2015, 96 (08): : 1404 - 1410
  • [7] Relationship between muscular impairment and psychological health with lower extremity functions in patients with transtibial amputation
    Aslam, Ayesha
    Shoukat, Harima
    Jahan, Saira
    [J]. JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2022, 72 (09) : 1788 - 1791
  • [8] Utilization of a lower extremity ambulatory feedback system to reduce gait asymmetry in transtibial amputation gait
    Yang, L.
    Dyer, P. S.
    Carson, R. J.
    Webster, J. B.
    Foreman, K. Bo
    Bamberg, S. J. M.
    [J]. GAIT & POSTURE, 2012, 36 (03) : 631 - 634
  • [9] Somatotype of the individuals with lower extremity amputation and its association with cardiovascular risk
    Mozumdar, Arupendra
    Roy, Subrata K.
    [J]. ANTHROPOLOGISCHER ANZEIGER, 2008, 66 (01) : 99 - 116
  • [10] Osteocutaneous Pedicle Flap Transfer for Salvage of Transtibial Amputation After Severe Lower-Extremity Injury
    Vallier, Heather A.
    Fitzgerald, Steven J.
    Beddow, Meghan E.
    Sontich, John K.
    Patterson, Brendan M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2012, 94A (05): : 447 - 454