Intensity-modulated radiation therapy using a variable-aperture collimator

被引:17
|
作者
Webb, S
Hartmann, G
Echner, G
Schlege, W
机构
[1] Inst Canc Res, Joint Dept Phys, Sutton SM2 5PT, Surrey, England
[2] Royal Marsden NHS Trust, Sutton SM2 5PT, Surrey, England
[3] DKFZ, D-69120 Heidelberg, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2003年 / 48卷 / 09期
关键词
D O I
10.1088/0031-9155/48/9/310
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper extends some earlier concepts of using a tertiary mask plus jaws for delivering IMRT without a multileaf collimator. The new concept is to sweep a variable-aperture collimator (VAC) across the space of the intensity-modulated beam (IMB) to be delivered and to strip this IMB down into multiple-static-field components, each deliverable with the VAC. The stripping algorithm is described and it is shown, for several designs of VAC, that the mean number of field components and mean number of monitor units is less using the VAC than would be required for a jaws-only (JO) decomposition. The VAC would be simpler to construct than several previously suggested jaws-plus-mask (J+M) combinations. As well as describing a simple VAC for the use with jaws, we propose a design concept of a hybrid VAC. We also show that adding the potential to rotate the simple or hybrid VAC for some components relative to the field to be modulated is advantageous.
引用
收藏
页码:1223 / 1238
页数:16
相关论文
共 50 条
  • [1] Direct aperture optimization for a variable aperture collimator for intensity-modulated radiation therapy
    Webb, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (05): : N47 - N55
  • [2] Comparative efficiency of the multi-leaf collimator and variable-aperture collimator in intensity-modulated radiotherapy
    Anderson, JW
    Symonds-Tayler, R
    Hartmann, G
    Echner, G
    Lang, C
    Schlegel, W
    Webb, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (07): : 1725 - 1736
  • [3] Intensity modulated radiation therapy using a variable aperture collimator (VAC)
    Webb, S
    Hartmann, G
    Echner, G
    Schlegel, W
    [J]. RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S97 - S97
  • [4] Direct aperture optimisation (DAO) for a variable aperture collimator (VAC) for intensity-modulated radiation therapy (IMRT)
    Webb, S
    Anderson, J
    Symonds-Tayler, R
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S176 - S176
  • [5] Intensity-modulated radiation therapy using a multileaf collimator
    Webb, S
    [J]. RADIATION RESEARCH, VOL 2, CONGRESS PROCEEDINGS, 2000, : 660 - 663
  • [6] Development of a variable-aperture collimator for small animal radiation
    Zhou, H.
    Chatterjee, R.
    Contag, C.
    Gambhir, S.
    Boyer, A.
    Keall, P.
    Graves, E.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2436 - 2436
  • [7] Monte Carlo modeling of variable-aperture collimator for small animal radiation therapy
    Zhou, H.
    Sawant, A.
    Keall, P.
    Graves, E.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2472 - 2472
  • [8] Aperture shape optimization in intensity-modulated radiation therapy planning
    Li-Yuan Zhang
    Zhi-Guo Gui
    Peng-Cheng Zhang
    Jie Yang
    [J]. Nuclear Science and Techniques, 2023, 34 (09) : 110 - 121
  • [9] Aperture shape optimization in intensity-modulated radiation therapy planning
    Zhang, Li-Yuan
    Gui, Zhi-Guo
    Zhang, Peng-Cheng
    Yang, Jie
    [J]. NUCLEAR SCIENCE AND TECHNIQUES, 2023, 34 (09)
  • [10] Aperture shape optimization in intensity-modulated radiation therapy planning
    Li-Yuan Zhang
    Zhi-Guo Gui
    Peng-Cheng Zhang
    Jie Yang
    [J]. Nuclear Science and Techniques, 2023, 34