A wearable potentiometric sensor with integrated salt bridge for sweat chloride measurement

被引:63
|
作者
Choi, Dong-Hoon [1 ]
Li, Yi [1 ]
Cutting, Garry R. [2 ]
Searson, Peter C. [1 ,3 ]
机构
[1] Johns Hopkins Univ, Inst Nanobiotechnol, 3400 North Charles St, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Pediat, Baltimore, MD 21218 USA
[3] Johns Hopkins Univ, Dept Mat Sci & Engn, 3400 North Charles St, Baltimore, MD 21218 USA
关键词
Potentiometric sensor; Wearable sensor; Sweat chloride; Cystic fibrosis; CYSTIC-FIBROSIS; SKIN TEMPERATURE; ELECTROLYTES; DIAGNOSIS; EXERCISE; ANALYZER; PANCREAS; SYSTEM; GLAND; WATER;
D O I
10.1016/j.snb.2017.04.129
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The development of wearable sensors to measure biomarkers in sweat remains a major technological challenge. Here we report on a wearable, potentiometric, thin film sweat chloride sensor. Potentiometric devices provide a relatively simple technology for sweat sensing, however, equilibration between the reference and test solutions is a significant source of error. We have developed a sweat chloride sensor with integrated salt bridge that minimizes equilibration and enables stable measurements over extended periods of time. The sensor shows a very small concentration drift even with small sample volumes. The measurement variation was less than 2 mM at low chloride ion concentration (10 mM) and 5 mM at high concentration (150 mM), spanning the range for healthy individuals and CF patients. Finally, in on-body tests we show that the sweat chloride concentration in healthy individuals is dependent on exercise intensity, indicating that the sensor has a potential for a fitness monitoring applications. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:673 / 678
页数:6
相关论文
共 50 条
  • [1] Wearable Potentiometric Chloride Sweat Sensor: The Critical Role of the Salt Bridge
    Choi, Dong-Hoon
    Kim, Jin Seob
    Cutting, Garry R.
    Searson, Peter C.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (24) : 12241 - 12247
  • [2] Green and Integrated Wearable Electrochemical Sensor for Chloride Detection in Sweat
    Lopresti, Francesco
    Patella, Bernardo
    Divita, Vito
    Zanca, Claudio
    Botta, Luigi
    Radacsi, Norbert
    O'Riordan, Alan
    Aiello, Giuseppe
    Kersaudy-Kerhoas, Maiwenn
    Inguanta, Rosalinda
    La Carrubba, Vincenzo
    [J]. SENSORS, 2022, 22 (21)
  • [3] The Dynamic Response of Sweat Chloride to Changes in Exercise Load Measured by a Wearable Sweat Sensor
    Dong-Hoon Choi
    Grant B. Kitchen
    Kerry J. Stewart
    Peter C. Searson
    [J]. Scientific Reports, 10
  • [4] The Dynamic Response of Sweat Chloride to Changes in Exercise Load Measured by a Wearable Sweat Sensor
    Choi, Dong-Hoon
    Kitchen, Grant B.
    Stewart, Kerry J.
    Searson, Peter C.
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [5] IonSens: A Wearable Potentiometric Sensor Patch for Monitoring Total Ion Content in Sweat
    Hoekstra, Rafael
    Blondeau, Pascal
    Andrade, Francisco J.
    [J]. ELECTROANALYSIS, 2018, 30 (07) : 1536 - 1544
  • [6] A wearable sensor for real-time measurement of the chloride ion concentration in sweat: Relevance to health and disease
    Searson, Peter
    Choi, Dong-Hoon
    Kitchen, Grant
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256
  • [7] A NOVEL WEARABLE SWEAT RATE SENSOR FOR BOTH DOMINANT AND RECESSIVE SWEAT RATE MEASUREMENT
    Gao, Kunpeng
    Wang, Xiaolin
    Yang, Bing
    Chen, Xiang
    Li, Xiuyan
    Liu, Jinquan
    [J]. 2019 20TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS & EUROSENSORS XXXIII (TRANSDUCERS & EUROSENSORS XXXIII), 2019, : 817 - 820
  • [8] Wearable potentiometric biosensor for analysis of urea in sweat
    Ibanez-Redin, Gisela
    Cagnani, Giovana Rosso
    Gomes, Nathalia O.
    Raymundo-Pereira, Paulo A.
    Machado, Sergio A. S.
    Gutierrez, Marco Antonio
    Krieger, Jose Eduardo
    Oliveira, Osvaldo N.
    [J]. BIOSENSORS & BIOELECTRONICS, 2023, 223
  • [9] Wireless wearable potentiometric sensor for simultaneous determination of pH, sodium and potassium in human sweat
    Jalal, Nahid Rezvani
    Madrakian, Tayyebeh
    Ahmadi, Mazaher
    Afkhami, Abbas
    Khalili, Sina
    Bahrami, Morteza
    Roshanaei, Majid
    [J]. SCIENTIFIC REPORTS, 2024, 14 (01):
  • [10] Out-of-clinic measurement of sweat chloride using a wearable sensor during low-intensity exercise
    Choi, Dong-Hoon
    Kitchen, Grant B.
    Jennings, Mark T.
    Cutting, Garry R.
    Searson, Peter C.
    [J]. NPJ DIGITAL MEDICINE, 2020, 3 (01)