Inter- and intra-observer agreement of femoroacetabular impingement (FAI) parameters comparing plain radiographs and advanced, 3D computed tomographic (CT)-generated hip models in a surgical patient cohort

被引:19
|
作者
Cadet, Edwin R. [1 ]
Babatunde, Oladapo M. [2 ]
Gorroochurn, Prakash [3 ]
Chan, Andrew K. [2 ]
Stancato-Pasik, Agata [4 ]
Brown, Marc [4 ]
Johnson, Skylar [2 ]
Kaiser, Philip Burns [2 ]
Gardner, Thomas R. [2 ]
Ayeni, Olufemi R. [5 ]
机构
[1] Raleigh Orthopaed Clin, 3001 Edwards Mill, Raleigh, NC 27612 USA
[2] Columbia Univ, Med Ctr, Dept Orthopaed Surg, New York Presbyterian Hosp, 622 W 168th St,PH-11, New York, NY 10032 USA
[3] Columbia Univ, Mailman Sch Publ Hlth, Dept Biostat, 722 W 168th St,R620, New York, NY 10032 USA
[4] Columbia Univ, Dept Radiol, 630 W 168th St,Suite MC28, New York, NY 10032 USA
[5] McMaster Univ, MacSports, 1200 Main St West,Room 4E17, Hamilton, ON L8S 4L8, Canada
关键词
Femoroacetabular impingement; Computed tomography; Models; Inter-observer agreement; RETROVERSION; JOINT;
D O I
10.1007/s00167-014-3315-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of our study was to investigate whether advanced, 3D computed tomographic (CT)-generated hip models improves inter-and intra-observer agreement when compared to plain radiographs in identifying femoroacetabular impingement (FAI) morphology. Eight consecutive patients who underwent surgery for FAI pathology were selected for this study. Preoperative CT scan image data were used to create high resolution, 3D hip reconstruction models. Four observers (two attending hip surgeons and radiologists) performed a blinded review of preselected radiographs and 3D CT hip models. Alpha and lateral center-edge angle measurements, location of cam lesion and the presence of a "crossover sign" were assessed. Inter- and intra-observer agreement was determined by calculating the intra-class correlation coefficients (ICC) or kappa coefficients to evaluate agreement for categorical variables. The parameter that demonstrated the highest and poorest inter-observer agreement was the presence of a "crossover sign" using 3D CT-generated high resolution hip models (ICC = 0.76, p = 0.00) and anteroposterior pelvis radiography, respectively (ICC = 0.20, p = 0.02). Alpha angle values were significantly higher using plain radiographs when compared to 3D hip reconstruction models (61.1A degrees +/- 10.4A degrees versus 55.4A degrees +/- 14.4A degrees, p = 0.003). Furthermore, when compared to radiographs, 3D hip reconstruction models demonstrated significantly higher intra-observer agreement (ICC = 0.856 versus 0.405, p = 0.005) when determining the presence of a "crossover sign". Our findings were suggestive that for most commonly used FAI morphology parameters, CT-generated hip models demonstrated little benefit over plain radiographs in improving inter-observer agreement among providers. III.
引用
收藏
页码:2324 / 2331
页数:8
相关论文
共 1 条
  • [1] Inter- and intra-observer agreement of femoroacetabular impingement (FAI) parameters comparing plain radiographs and advanced, 3D computed tomographic (CT)-generated hip models in a surgical patient cohort
    Edwin R. Cadet
    Oladapo M. Babatunde
    Prakash Gorroochurn
    Andrew K. Chan
    Agata Stancato-Pasik
    Marc Brown
    Skylar Johnson
    Philip Burns Kaiser
    Thomas R. Gardner
    Olufemi R. Ayeni
    Knee Surgery, Sports Traumatology, Arthroscopy, 2016, 24 : 2324 - 2331