Diagnostic accuracy of endoscopic ultrasound and intraductal ultrasonography for assessment of ampullary tumors: a meta-analysis

被引:6
|
作者
Ye, Xiaohua [1 ]
Wang, Lei [2 ]
Jin, Zhendong [2 ]
机构
[1] Zhejiang Univ, Affiliated Jinhua Hosp, Dept Gastroenterol, Sch Med, Jinhua, Zhejiang, Peoples R China
[2] Naval Med Univ, Changhai Hosp, Digest Endoscopy Ctr, Dept Gastroenterol, Shanghai 200433, Peoples R China
关键词
Meta-analysis; EUS; IDUS; ampullary tumors; PREOPERATIVE EVALUATION; TRANSABDOMINAL SONOGRAPHY; SYSTEMATIC REVIEWS; STAGING ACCURACY; VATER; PAPILLA; EUS; CARCINOMA; US; CT;
D O I
10.1080/00365521.2022.2067785
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background Accurate preoperative assessment of ampullary tumors (ATs) is critical for determining the appropriate treatment. The reported diagnostic accuracy of endoscopic ultrasound (EUS) and intraductal ultrasonography (IDUS) for detecting tumor depth (T-staging) and regional lymph node status (N-staging) varies across studies. Method An electronic search of the MEDLINE and Embase databases was conducted to identify studies that assessed the diagnostic accuracy of EUS and IDUS for ATs. Sensitivities and specificities of eligible studies were summarized using either fixed effects or random-effects model. Results Twenty-one studies were included in the final analysis. The pooled sensitivity and specificity of EUS were 0.89 and 0.87 for T1, 0.76 and 0.91 for T2, 0.81 and 0.94 for T3 and 0.72 and 0.98 for T4, respectively. For IDUS, estimates from five studies were 0.90 and 0.88 for T1, 0.73 and 0.91 for T2 and 0.79 and 0.97 for T3, respectively. For N-staging, 16 studies using EUS were included with sensitivity and specificity of 0.61 and 0.77, respectively. Moreover, estimates of IDUS for N-staging were 0.61 and 0.92, respectively. Conclusion Our results imply that EUS and IDUS have good diagnostic accuracy for T-staging of ATs. However, the accuracy of EUS or IDUS is less satisfactory for N-staging. More well-designed prospective studies are warranted to confirm our findings.
引用
收藏
页码:1158 / 1168
页数:11
相关论文
共 50 条
  • [1] Staging accuracy of ampullary tumors by endoscopic ultrasound: Meta-analysis and systematic review
    Trikudanathan, Guru
    Njei, Basile
    Attam, Rajeev
    Arain, Mustafa
    Shaukat, Aasma
    DIGESTIVE ENDOSCOPY, 2014, 26 (05) : 617 - 626
  • [2] Endoscopic ultrasound and intraductal ultrasonography are complementary for the management of ampullary tumors.
    Napoleon, B
    Saurin, JC
    Albis, R
    Scoazec, JY
    Ponchon, T
    Fumex, J
    Pujol, B
    Chayvialle, JA
    GASTROINTESTINAL ENDOSCOPY, 2000, 51 (04) : AB186 - AB186
  • [3] THE ASSESSMENT OF AMPULLARY TUMORS BY ENDOSCOPIC ULTRASONOGRAPHY
    BARKUN, AN
    JONES, S
    BOWIE, J
    NICKL, N
    AFFRONTI, J
    COTTON, PB
    GASTROINTESTINAL ENDOSCOPY, 1990, 36 (02) : 207 - 207
  • [4] Do endoscopic ultrasound and intraductal ultrasonography select accurately ampullary tumors for a curative endoscopic snare resection?
    Napoléon, B
    Saurin, JC
    Scoazec, J
    Pialat, J
    Ponchon, T
    Pujol, B
    GASTROINTESTINAL ENDOSCOPY, 2002, 56 (04) : S129 - S129
  • [5] Diagnostic accuracy of endoscopic ultrasound with artificial intelligence for gastrointestinal stromal tumors: A meta-analysis
    Ye, Xiao Hua
    Zhao, Lin Lin
    Wang, Lei
    JOURNAL OF DIGESTIVE DISEASES, 2022, 23 (5-6) : 253 - 261
  • [6] Diagnostic accuracy of ultrasonography for the assessment of maxillofacial fractures: A meta-analysis
    Gadicherla, Srikanth
    Pentapati, Kalyana-Chakravarthy
    Rustaqi, Nasrullah
    Singh, Anupam
    Smriti, Komal
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2021, 11 (05): : 503 - 509
  • [7] Endoscopic Diagnosis of Ampullary Tumors Using Conventional Endoscopic Ultrasonography and Intraductal Ultrasonography in the Era of Endoscopic Papillectomy: Advantages and Limitations
    Moon, Jong Ho
    CLINICAL ENDOSCOPY, 2014, 47 (02) : 127 - 128
  • [8] The diagnostic accuracy and strength of agreement between endoscopic ultrasound and histopathology in the staging of ampullary tumors
    Wee E.
    Lakhtakia S.
    Gupta R.
    Anuradha S.
    Shetty M.
    Kalapala R.
    Monga A.
    Saravanan A.
    Rebala P.
    Ramchandani M.
    Rao G.V.
    Reddy D.N.
    Indian Journal of Gastroenterology, 2012, 31 (6) : 324 - 332
  • [9] Diagnostic accuracy of endoscopic ultrasound in pancreatic neuroendocrine tumors: A systematic review and meta analysis
    Srinivas R Puli
    Nikhil Kalva
    Matthew L Bechtold
    Smitha R Pamulaparthy
    Micheal D Cashman
    Norman C Estes
    Richard H Pearl
    Fritz-Henry Volmar
    Sonu Dillon
    Michael F Shekleton
    David Forcione
    World Journal of Gastroenterology, 2013, 19 (23) : 3678 - 3684
  • [10] Diagnostic accuracy of endoscopic ultrasound in pancreatic neuroendocrine tumors: A systematic review and meta analysis
    Puli, Srinivas R.
    Kalva, Nikhil
    Bechtold, Matthew L.
    Pamulaparthy, Smitha R.
    Cashman, Micheal D.
    Estes, Norman C.
    Pearl, Richard H.
    Volmar, Fritz-Henry
    Dillon, Sonu
    Shekleton, Michael F.
    Forcione, David
    WORLD JOURNAL OF GASTROENTEROLOGY, 2013, 19 (23) : 3678 - 3684