摘要
Accurate quantitation of aldosterone is critical for the clinical detection of hypertension. However, no reference intervals for aldosterone in healthy volunteers and patients with hypertension have yet been established using highly sensitive methods with a wide linear range based on low plasma volumes. We developed a modified ultra-performance liquid chromatography-tandem mass spectrometry (UPL-CMS/MS) method for the quantitation of aldosterone and established reference intervals for healthy volunteers and patients with hypertension. We measured aldosterone by UPLC-MS/MS in human plasma samples (90 AL). We established a reference range for aldosterone based on blood collected midmorning from 888 patients with hypertension and 258 seated, normotensive subjects. The linear range was 10-5000 pg/mL (r(2) > 0.995), with a limit of quantification of 10 pg/ml. Similar results were obtained using different collection tubes, including EDTA plasma, sodium citrate plasma, and serum, respectively. Based on a comparison of results from UPLC-MS/MS and enzyme-linked immunosorbent assay, we derived the equation: UPLC-MS/MS = 0.8444 x ELISA + 1.162. Aldosterone concentrations in normotensive subjects ranged from 12.76 to 196.21 pg/mL, with no effect of age or sex on the reference interval. Aldosterone levels were significantly higher in patients with hypertension versus healthy controls (median: 71.05 versus 52.54 pg/mL, P < 0.0001), and patients with secondary hypertension versus primary hypertension (median: 67.25 versus 46.70 pg/mL, P=0.0128) which were age- and sex-matched. Reference intervals for aldosterone in healthy individuals and patients with hypertension were established based on an improved UPLC-MS/MS method with higher sensitivity, a wider linear range, and lower plasma volume. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Quantitation of aldosterone in human plasma by ultra high performance liquid chromatography tandem mass spectrometry
    Hinchliffe, Edward
    Carter, Stephanie
    Owen, Laura J.
    Keevil, Brian G.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 913 : 19 - 23
  • [2] Developing an ultra-performance liquid chromatography-tandem mass spectrometry for detecting aldosterone in human plasma
    Lin, Wenbin
    Yao, Zhenrong
    Li, Yuzhe
    Liao, Zhihao
    Xiao, Jiahao
    Chen, Yonghong
    Feng, Pinning
    Gan, Wenjia
    [J]. JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (11)
  • [3] Quantification of levornidazole and its metabolites in human plasma and urine by ultra-performance liquid chromatography-mass spectrometry
    Cao, Yuran
    Zhao, Miao
    Wu, Xiaojie
    Guo, Beining
    Chen, Yuancheng
    Yu, Jicheng
    Cao, Guoying
    Zhang, Jing
    Shi, Yaoguo
    Zhang, Yingyuan
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 963 : 119 - 127
  • [4] Rapid quantitation of testosterone hydroxyl metabolites by ultra-performance liquid chromatography and mass spectrometry
    Wang, Dandan
    Zhang, Minli
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 855 (02): : 290 - 294
  • [5] Simultaneous quantitation and size characterization of apolipoprotein(a) by ultra-performance liquid chromatography/mass spectrometry
    Lassman, Michael E.
    McLaughlin, Theresa M.
    Zhou, Haihong
    Pan, Yi
    Marcovina, Santica M.
    Laterza, Omar
    Roddy, Thomas P.
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2014, 28 (10) : 1101 - 1106
  • [6] Development and validation of an analytical procedure for quantitation of surfactants in dishwashing detergents using ultra-performance liquid chromatography-mass spectrometry
    Wu, Hsin-Yi
    Shih, Chia-Lung
    Lee, Ton
    Chen, Tai-Yuan
    Lin, Lan-Chi
    Lin, Kuan-Yu
    Chang, Hui-Chuan
    Chuang, I-Chi
    Liou, Shih-Yuan
    Liao, Pao-Chi
    [J]. TALANTA, 2019, 194 : 778 - 785
  • [7] Determination of 12 Oligosaccharides in Human Milk by Ultra-Performance Liquid Chromatography-Mass Spectrometry
    [J]. Li, Cheng (lichenglcp@163.com), 2018, Chinese Chamber of Commerce (39):
  • [8] Ultra-performance liquid chromatography-mass spectrometry as a sensitive and powerful technology in lipidomic applications
    Zhao, Ying-Yong
    Wu, Shao-Ping
    Liu, Shuman
    Zhang, Yongmin
    Lin, Rui-Chao
    [J]. CHEMICO-BIOLOGICAL INTERACTIONS, 2014, 220 : 181 - 192
  • [9] Determination of polyphenols in Chinese jujube using ultra-performance liquid chromatography-mass spectrometry
    Liu, Hongxia
    Guo, Xiaohua
    Wu, Jingjie
    Liu, Hui
    Deng, Benliang
    Zhao, Xusheng
    [J]. OPEN CHEMISTRY, 2023, 21 (01):
  • [10] Plasma metabonomics study of the patients with acute anterior uveitis based on ultra-performance liquid chromatography-mass spectrometry
    Guo, Junguo
    Yan, Tingqin
    Bi, Hongsheng
    Xie, Xiaofeng
    Wang, Xingrong
    Guo, Dadong
    Jiang, Haiqiang
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (06) : 925 - 934