Simultaneous determination of short-chain chlorinated paraffins and other classes of persistent organic pollutants in sediment by gas chromatography-tandem mass spectrometry after ultrasonic solvent extraction combined with stir bar sorptive extraction

被引:2
|
作者
Tolgyessy, Peter [1 ]
Nagyova, Slavka [1 ]
Rosko, Vladimir [2 ]
Hucko, Pavel [2 ]
机构
[1] Water Res Inst, Slovak Natl Water Reference Lab, Nabrezie Arm Gen L Svobodu 5, Bratislava 81249, Slovakia
[2] Water Res Inst, Groundwater Protect Dept, Nabrezie Arm Gen L Svobodu 5, Bratislava 81249, Slovakia
关键词
Short-chain chlorinated paraffins; Persistent organic pollutants; Sediment extraction; Stir bar sorptive extraction; Thermal desorption; Gas chromatography-tandem mass spectrometry; POLYBROMINATED DIPHENYL ETHERS; POLYCHLORINATED-BIPHENYLS; MARINE-SEDIMENTS; ASSISTED EXTRACTION; FOOD; MICROPOLLUTANTS; MICROEXTRACTION; CONTAMINANTS; MS/MS; BIOTA;
D O I
10.1007/s11696-021-01738-0
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The study presents a fast and high throughput method for determination of short-chain chlorinated paraffins (SCCPs) together with other halogenated persistent organic pollutants (POPs) in sediment. The analytes (SCCPs, 11 polychlorinated biphenyls, 6 polybrominated diphenyl ethers, 11 organochlorine compounds) were determined in a single gas chromatography-triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS) run after miniaturized sample preparation combining ultrasonic solvent extraction (USE) and stir bar sorptive extraction (SBSE). The method was validated in terms of selectivity, matrix effect, matrix-matched recovery, linearity and range, detection and quantification limits (LOD and LOQ) and accuracy (including analysis of certified reference materials). The QqQ-MS/MS detector allowed the determination of all target analytes without interferences. The LODs and LOQs for SCCPs were 6.5 and 22 ng g(-1) dw (dry weight), while for other analytes were in the ranges 0.029-0.073 ng g(-1) and 0.097-0.24 ng g(-1), respectively. The recoveries for all the analytes were in the range 84-101% with relative standard deviations in the range 5.5-19%. In terms of environmental impact, the method was classified as "an excellent green analysis method". Finally, the method was compared with other published methods and its applicability was confirmed by the analysis of sediment samples collected in 23 Slovak water reservoirs during a survey conducted in 2019. [GRAPHICS] .
引用
收藏
页码:5645 / 5661
页数:17
相关论文
共 50 条
  • [1] Simultaneous determination of short-chain chlorinated paraffins and other classes of persistent organic pollutants in sediment by gas chromatography‒tandem mass spectrometry after ultrasonic solvent extraction combined with stir bar sorptive extraction
    Peter Tölgyessy
    Slávka Nagyová
    Vladimír Roško
    Pavel Hucko
    Chemical Papers, 2021, 75 : 5645 - 5661
  • [2] Green and sensitive method combining ultrasonic solvent extraction, stir bar sorptive extraction and thermal desorption-gas chromatography-tandem mass spectrometry for determination of organotin compounds in sediment
    Nagyova, Slavka
    Tolgyessy, Peter
    Hrouzkova, Svetlana
    MICROCHEMICAL JOURNAL, 2024, 207
  • [3] Determination of short chain chlorinated paraffins in water by stir bar sorptive extraction-thermal desorption-gas chromatography-triple quadrupole tandem mass spectrometry
    Tolgyessy, P.
    Nagyova, S.
    Sladkovicova, M.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1494 : 77 - 80
  • [4] Determination of nitroaromatic explosive residues in water by stir bar sorptive extraction-gas chromatography-tandem mass spectrometry
    Mathieu Galmiche
    Adeline Colin
    Marie-Christelle Clavos
    Christelle Pallez
    Christophe Rosin
    Xavier Dauchy
    Analytical and Bioanalytical Chemistry, 2021, 413 : 159 - 169
  • [5] Determination of nitroaromatic explosive residues in water by stir bar sorptive extraction-gas chromatography-tandem mass spectrometry
    Galmiche, Mathieu
    Colin, Adeline
    Clavos, Marie-Christelle
    Pallez, Christelle
    Rosin, Christophe
    Dauchy, Xavier
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (01) : 159 - 169
  • [6] Rapid and selective determination of UV filters in seawater by liquid chromatography-tandem mass spectrometry combined with stir bar sorptive extraction
    Nguyen, Kieu T. N.
    Scapolla, Carlo
    Di Carro, Marina
    Magi, Emanuele
    TALANTA, 2011, 85 (05) : 2375 - 2384
  • [7] Simultaneous Determination of Seven Preservatives in Beverage and Jam Using Stir Bar Sorptive Extraction and Gas Chromatography-Tandem Mass Spetrometry
    Chen Qi
    Ling Yun
    Zhang Feng
    Huang Jun-Rong
    Chu Xiao-Gang
    Wu Yong-Ning
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (08) : 1156 - 1160
  • [8] Ultra-trace determination of Persistent Organic Pollutants in Arctic ice using stir bar sorptive extraction and gas chromatography coupled to mass spectrometry
    Lacorte, S.
    Quintana, J.
    Tauler, R.
    Ventura, F.
    Tovar-Sanchez, A.
    Duarte, C. M.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (49) : 8581 - 8589
  • [9] Development of a stir bar sorptive extraction and thermal desorption-gas chromatography-mass spectrometry method for the simultaneous determination of several persistent organic pollutants in water samples
    Prieto, A.
    Zuloaga, O.
    Usobiaga, A.
    Etxebarria, N.
    Fernandez, L. A.
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1174 (1-2) : 40 - 49
  • [10] Contribution to the determination of tributyltin in water by stir bar sorptive extraction-thermal desorption-gas chromatography-tandem mass spectrometry
    Tolgyessy, Peter
    Nagyova, Slavka
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1678