Diagnostic Yield of Fine-Needle Aspiration for Axillary Lymph Nodes During Screening Breast Ultrasound

被引:3
|
作者
Youn, Inyoung [1 ,2 ]
Kim, Eun-Kyung [1 ]
Yoon, Jung Hyun [1 ]
Moon, Hee Jung [1 ]
Kim, Min Jung [1 ]
机构
[1] Yonsei Univ, Coll Med, Severance Hosp, Res Inst Radiol Sci,Dept Radiol, 50 Yonsei Ro, Seoul 120752, South Korea
[2] Sungkyunkwan Univ, Kangbuk Samsung Hosp, Dept Radiol, Seoul, South Korea
关键词
biopsy; fine-needle; axilla; mass screening; breast; ultrasonography; CANCER; MAMMOGRAPHY; SONOGRAPHY; METASTASIS; RISK;
D O I
10.1097/RUQ.0000000000000236
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of our study was to assess the positive predictive value (PPV) of ultrasound (US)-guided fine-needle aspiration (FNA) and the cancer detection rate for incidentally detected abnormal axillary lymph node (LN) in patients who underwent screening US. We retrospectively reviewed 72 LNs of 69 patients (mean age, 44.9 years) who underwent US-FNA for incidentally detected abnormal axillary LNs on 50,488 screening US from January 2005 to December 2011. The PPV of US-FNA and the cancer detection rate were calculated. We evaluated US images for lymph node size, abnormal findings (hilum loss, eccentric cortical thickening, round shape, extranodal extension, or marked hypoechoic cortex), and mammography for the identification of abnormal LNs. The PPV of each finding was also calculated. The PPV of US-FNA and the cancer detection rate were 2.8% (2/72) and 0.004% (2/50,488), respectively. The mean (SD) measurements for long-axis, short-axis, and cortical thickening of the LNs were 14.9 (5.9) mm, 8.5 (3.5) mm, and 5.8 (2.8) mm, respectively. Of the positive LNs, US findings of hilum loss, eccentric cortical thickening, and extranodal extension were found, and each corresponding PPV was 6.3% (1/16), 1.8% (1/56), and 14.3% (1/7), respectively. The PPV of mammography was 14.3% (1/7). Our results suggest that the PPVs of US-FNA and the cancer detection rate for incidentally detected abnormal axillary LNs during screening US are too low to recommend axillary US during breast US screening and that follow-up is acceptable for abnormal LNs detected during screening breast US that do not have extranodal extension or are negative on mammography.
引用
收藏
页码:144 / 150
页数:7
相关论文
共 50 条
  • [1] Fine-needle aspiration biopsy of axillary lymph nodes
    Jaffer, S
    Zakowski, M
    [J]. DIAGNOSTIC CYTOPATHOLOGY, 2002, 26 (02) : 69 - 74
  • [2] Fine-needle aspiration biopsy of axillary lymph nodes: A reliable diagnostic tool for breast cancer staging
    Sallout, Luai
    Tashkandi, Mohamed
    Moqnas, Amani
    AlMajed, Hebah
    Al-Naeem, Abdulrhman
    Alwelaie, Yazeed
    [J]. CANCER CYTOPATHOLOGY, 2024, 132 (02) : 103 - 108
  • [3] Ultrasound-guided fine-needle aspiration of axillary lymph nodes in breast cancer: Diagnostic accuracy and role in surgical management
    Iwamoto, Naoko
    Aruga, Tomoyuki
    Horiguchi, Shinichiro
    Asami, Hidekazu
    Saita, Chiaki
    Onishi, Mai
    Goto, Risa
    Ishiba, Toshiyuki
    Honda, Yayoi
    Miyamoto, Hiromi
    Kuroi, Katsumasa
    [J]. DIAGNOSTIC CYTOPATHOLOGY, 2019, 47 (08) : 788 - 792
  • [4] Fine-needle aspiration of lymph nodes
    Parrish, AG
    [J]. SOUTH AFRICAN MEDICAL JOURNAL, 1997, 87 (03): : 342 - 342
  • [5] False-negative ultrasound-guided fine-needle aspiration of axillary lymph nodes in breast cancer patients
    Iwamoto, Naoko
    Aruga, Tomoyuki
    Asami, Hidekazu
    Horiguchi, Shin-ichiro
    [J]. CYTOPATHOLOGY, 2020, 31 (05) : 463 - 467
  • [6] The value of preoperative ultrasound guided fine-needle aspiration cytology of radiologically suspicious axillary lymph nodes in breast cancer
    Sauer, Torill
    Karesen, Rolf
    [J]. CYTOJOURNAL, 2014, 11 : 26
  • [7] The Role of Ultrasound-Guided Fine-Needle Aspiration of Axillary Nodes in the Staging of Breast Cancer
    Ajay Jain
    Mary Ellen Haisfield-Wolfe
    Julie Lange
    Nita Ahuja
    Nagi Khouri
    Theodore Tsangaris
    Zhe Zhang
    Charles Balch
    Lisa K. Jacobs
    [J]. Annals of Surgical Oncology, 2008, 15 : 462 - 471
  • [8] The role of ultrasound-guided fine-needle aspiration of axillary nodes in the staging of breast cancer
    Jain, Ajay
    Haisfield-Wolfe, Mary Ellen
    Lange, Julie
    Ahuja, Nita
    Khouri, Nagi
    Tsangaris, Theodore
    Zhang, Zhe
    Balch, Charles
    Jacobs, Lisa K.
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2008, 15 (02) : 462 - 471
  • [9] Axillary Lymph Node Fine-Needle Aspiration: An Underutilized Diagnostic Tool for Breast Cancer Staging
    Sallout, Luai
    Tashkandi, Mohamed
    Moqnas, Amani
    Al-Majed, Hebah
    Alwelaie, Yazeed
    [J]. LABORATORY INVESTIGATION, 2023, 103 (03) : S354 - S355
  • [10] Role of ultrasound-guided fine-needle aspiration of indeterminate and suspicious axillary lymph nodes in the initial staging of breast carcinoma
    Krishnamurthy, S
    Sneige, N
    Bedi, DG
    Edieken, BS
    Fornage, BD
    Kuerer, HM
    Singletary, SE
    Hunt, KK
    [J]. CANCER, 2002, 95 (05) : 982 - 988