Automation of radiation treatment planning Evaluation of head and neck cancer patient plans created by the Pinnacle3 scripting and Auto-Planning functions

被引:0
|
作者
Speer, Stefan [1 ]
Klein, Andreas [2 ]
Kober, Lukas [3 ]
Weiss, Alexander [1 ]
Yohannes, Indra [4 ]
Bert, Christoph [1 ]
机构
[1] Friedrich Alexander Univ Erlangen Nurnberg, Univ Klinikum Erlangen, Dept Radiat Oncol, Univ Str 27, D-91054 Erlangen, Germany
[2] EKS Engn GmbH, Dr Mack Str 88, D-90762 Furth, Germany
[3] Strahlentherapie Tauber Franken, Uhlandstr 7, D-97980 Bad Mergentheim, Germany
[4] Rinecker Proton Therapy Ctr, Schaftlarnstr 133, D-81371 Munich, Germany
关键词
Radiotherapy; intensity-modulated; Organs at risk; Spinal cord; Brainstem; Parotid gland; OPTIMIZATION; THERAPY;
D O I
10.1007/s00066-017-1150-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Intensity-modulated radiotherapy (IMRT) techniques are now standard practice. IMRT or volumetric- modulated arc therapy (VMAT) allow treatment of the tumor while simultaneously sparing organs at risk. Nevertheless, treatment plan quality still depends on the physicist's individual skills, experiences, and personal preferences. It would therefore be advantageous to automate the planning process. This possibility is offered by the Pinnacle(3) treatment planning system (Philips Healthcare, Hamburg, Germany) via its scripting language or AutoPlanning (AP) module. Materials and methods AP module results were compared to in-house scripts and manually optimized treatment plans for standard head and neck cancer plans. Multiple treatment parameters were scored to judge plan quality (100 points = optimum plan). Patients were initially planned manually by different physicists and re-planned using scripts or AP. Results and discussion Script-based head and neck plans achieved a mean of 67.0 points and were, on average, superior to manually created (59.1 points) and AP plans (62.3 points). Moreover, they are characterized by reproducibility and lower standard deviation of treatment parameters. Even less experienced staff are able to create at least a good starting point for further optimization in a short time. However, for particular plans, experienced planners perform even better than scripts or AP. Experienced-user input is needed when setting up scripts or AP templates for the first time. Moreover, some minor drawbacks exist, such as the increase of monitor units (+ 35.5% for scripted plans). Conclusion On average, automatically created plans are superior to manually created treatment plans. For particular plans, experienced physicists were able to perform better than scripts or AP; thus, the benefit is greatest when time is short or staff inexperienced.
引用
收藏
页码:656 / 665
页数:10
相关论文
共 50 条
  • [1] Automation of radiation treatment planning: Evaluation of head and neck cancer patient plans created by the Pinnacle3 scripting and Auto-Planning functions; [Automatisierte Bestrahlungsplanung: Auswertung von mit Pinnacle3 via Scripting und Auto-Planning erzeugten Bestrahlungsplänen von Patienten mit Kopf-Hals-Tumor]
    Speer S.
    Klein A.
    Kober L.
    Weiss A.
    Yohannes I.
    Bert C.
    Strahlentherapie und Onkologie, 2017, 193 (8) : 656 - 665
  • [2] Using Pinnacle3 Auto-Planning with Sun Nuclear Feasibility
    Kuhls-Gilcrist, A.
    Miller, D.
    Nunez, D. Aramburu
    MEDICAL PHYSICS, 2018, 45 (06) : E517 - E517
  • [3] Evaluation of auto-planning in IMRT and VMAT for head and neck cancer
    Ouyang, Zi
    Shen, Zhilei Liu
    Murray, Eric
    Kolar, Matt
    LaHurd, Danielle
    Yu, Naichang
    Joshi, Nikhil
    Koyfman, Shiomo
    Bzdusek, Karl
    Xia, Ping
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (07): : 39 - 47
  • [4] Head & Neck VMAT Auto-Planning in Pinnacle. A class solution.
    Van Kollenburg, P. G. M.
    Bouwmans, L. C. W.
    Kusters, J. M. A. M.
    Brunenberg, E. J. L.
    Kunze-Busch, M. C.
    Dijkema, T.
    Kaanders, J. H. A. M.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S602 - S603
  • [5] Automated VMAT planning in Pinnacle3: a dosimetric study in head-neck cancer
    Cilla, S.
    Ianiro, A.
    Macchia, G.
    Romani, F.
    Angelini, A. L.
    Buwenge, M.
    Cammelli, S.
    Valentini, V.
    Morganti, A. G.
    Deodato, F.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1014 - S1015
  • [6] A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE3 PLANNING SYSTEM
    Suditu, M. D.
    Adam, D.
    Popa, R.
    Ciocaltei, V.
    ROMANIAN REPORTS IN PHYSICS, 2014, 66 (02) : 401 - 410
  • [7] Clinical validation of solid IMRT with the Pinnacle3 radiation treatment planning system
    Savitskij, D.
    Nelms, B.
    Gluckman, G.
    MEDICAL PHYSICS, 2006, 33 (06) : 2079 - 2079
  • [8] Evaluation of Intensity Modulated Radiation Therapy Planning for Cervical Cancer Based On Auto-Planning
    Zhang, R.
    Gao, Y.
    Bai, W.
    Mingchang, M.
    Chi, Z.
    MEDICAL PHYSICS, 2019, 46 (06) : E559 - E559
  • [9] Fast Aggregation of an Arbitrary Number of DVH Parameters Using Pinnacle On the Example of a Head and Neck Auto-Planning Study
    Exner, F.
    Richter, A.
    Weick, S.
    Sauer, O.
    MEDICAL PHYSICS, 2019, 46 (06) : E602 - E602
  • [10] Evaluation of the clinical application of Auto-Planning module for IMRT plans of left breast cancer
    Liu, Fang-Yu
    Dong, Zhi-Wei
    Yang, Hui-Bin
    Shi, Hong-Yun
    RADIATION PHYSICS AND CHEMISTRY, 2020, 166