Research on Contact Performance of Aviation Electrical Connector under Atmospheric Turbulence

被引:4
|
作者
Luo, Yanyan [1 ]
Wang, Guoping [1 ]
Cai, Ming [2 ]
Zhang, Le [3 ]
Zhang, Zhaopan [4 ]
机构
[1] Hebei Univ Technol, State Key Lab Reliabil & Intelligence Elect Equip, Tianjin, Peoples R China
[2] Hebei Far East Commun Syst Engn Co Ltd, Shijiazhuang, Hebei, Peoples R China
[3] State Grid Hebei Elect Power Co Co Ltd, Pingshan Power Supply Branch, Shijiazhuang, Hebei, Peoples R China
[4] State Grid Shandong Elect Power Co Maintenance Co, Jinan, Shandong, Peoples R China
来源
IEICE TRANSACTIONS ON ELECTRONICS | 2021年 / E104C卷 / 03期
关键词
electrical connector; turbulence; detecting techniques; contact force; contact resistance; RESISTANCE; PREDICTION; WEAR;
D O I
10.1587/transele.2020ECP5022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical connectors are the basic components of the electric system in automobiles, aircrafts and ships to realize the current and electrical signal transmission. In the aviation electrical system, the electrical connectors are indispensable supporting devices accessories, which play important roles in connecting electrical system, monitoring and controlling equipment, and provide a guarantee for the reliable transmission of electrical signals between the aviation equipment and system. Whether aviation electrical connectors work reliably directly affects the safety and reliability of the entire aircraft aviation system. The random vibration of aircraft caused by turbulence during flight is one of the main factors affecting the contact performance of the electrical connectors. In this paper, the contacts of the circular four-slot three-pin electrical connectors were chosen as the research specimens. The theoretical model of the contact force for contacts of electrical connectors was established. The test method for contact force measurement was determined. According to the test scheme, the detecting device for the contact force and contact resistance of the electrical connectors was designed, and the turbulence test of the electrical connectors was carried out. Through the analysis of the test data, the influence rule of the turbulence degree, flight speed and flight height on the contact force and contact resistance of the aviation electrical connectors was obtained.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 50 条
  • [1] Dynamic Performance of Electrical Connector Contact Resistance and Intermittent Fault Under Vibration
    Shen, Qinmu
    Lv, Kehong
    Liu, Guanjun
    Qiu, Jing
    IEEE TRANSACTIONS ON COMPONENTS PACKAGING AND MANUFACTURING TECHNOLOGY, 2018, 8 (02): : 216 - 225
  • [2] Evolution of contact performance of industry electrical connector based on reliability accelerated testing
    Ni, Jing
    Han, Lidong
    Pan, Jianfeng
    Zheng, Junqiang
    Shi, Yu
    Cui, Zhi
    Cai, Jun
    ADVANCES IN MECHANICAL ENGINEERING, 2021, 13 (02)
  • [3] Technique for Improving the Performance of FSO Under Atmospheric Turbulence
    Varshney, Deeksha
    Bhatia, Richa
    PROCEEDINGS OF THE 2019 6TH INTERNATIONAL CONFERENCE ON COMPUTING FOR SUSTAINABLE GLOBAL DEVELOPMENT (INDIACOM), 2019, : 581 - 583
  • [4] Experimental Investigation of the Electrical Contact Characteristics in Rolling Contact Connector
    Chen, Junxing
    Yang, Fei
    Luo, Kaiyu
    Wu, Yi
    Rong, Mingzhe
    PROCEEDINGS OF THE 2015 SIXTY-FIRST IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS (HOLM), 2015, : 235 - 240
  • [5] Experimental investigation on the electrical contact behavior of rolling contact connector
    Chen, Junxing
    Yang, Fei
    Luo, Kaiyu
    Zhu, Mingliang
    Wu, Yi
    Rong, Mingzhe
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (12):
  • [6] CLEAR-AIR TURBULENCE, AVIATION, AND ATMOSPHERIC SCIENCE
    DUTTON, JA
    REVIEWS OF GEOPHYSICS AND SPACE PHYSICS, 1971, 9 (03): : 613 - &
  • [7] Performance Evaluation of FSO System under Atmospheric Turbulence and Noise
    Sridhar B.
    Sridhar S.
    Nanchariah V.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (6) : 2085 - 2095
  • [8] ELECTRICAL EFFECTS OF FRETTING CONNECTOR CONTACT MATERIALS - A REVIEW
    ANTLER, M
    WEAR, 1985, 106 (1-3) : 5 - 33
  • [9] The effect of initial connector insertions on electrical contact resistance
    Jackson, Robert L.
    Ashurst, W. Robert
    Flowers, George T.
    Angadi, Santosh
    Choe, Song-Yul
    Bozack, Michael J.
    PROCEEDINGS OF THE 53RD IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2007, : 17 - +
  • [10] Research on piston error sensing for segmented mirrors under atmospheric turbulence
    Wang, Bin
    Jin, Zhenyu
    Dai, Yichun
    Yang, DeHua
    Xu, FangYu
    OPTICS EXPRESS, 2023, 31 (20) : 33719 - 33731